Linear accelerator–magnetic resonance (linac-MR) hybrid systems allow for real-time magnetic resonance imaging (MRI)-guided radiotherapy for more accurate dose delivery to the tumor and improved sparing of the adjacent healthy tissues. However, for real-time tumor detection, it is unfeasible for a human expert to manually contour (gold standard) the tumor at the fast imaging rate of a linac-MR. This study aims to develop a neural network-based tumor autocontouring algorithm with patient-specific hyperparameter optimization (HPO) and to validate its contouring accuracy using in vivo MR images of cancer patients. Two-dimensional (2D) intrafractional MR images were acquired at 4 frames/s using 3 tesla (T) MRI from 11 liver, 24 prostate, and 12 lung cancer patients. A U-Net architecture was applied for tumor autocontouring and was further enhanced by implementing HPO using the Covariance Matrix Adaptation Evolution Strategy. Six hyperparameters were optimized for each patient, for which intrafractional images and experts’ manual contours were input into the algorithm to find the optimal set of hyperparameters. For evaluation, Dice’s coefficient (DC), centroid displacement (CD), and Hausdorff distance (HD) were computed between the manual contours and autocontours. The performance of the algorithm was benchmarked against two standardized autosegmentation methods: non-optimized U-Net and nnU-Net. For the proposed algorithm, the mean (standard deviation) DC, CD, and HD of the 47 patients were 0.92 (0.04), 1.35 (1.03), and 3.63 (2.17) mm, respectively. Compared to the two benchmarking autosegmentation methods, the proposed algorithm achieved the best overall performance in terms of contouring accuracy and speed. This work presents the first tumor autocontouring algorithm applicable to the intrafractional MR images of liver and prostate cancer patients for real-time tumor-tracked radiotherapy. The proposed algorithm performs patient-specific HPO, enabling accurate tumor delineation comparable to that of experts.

1 October 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MWMark Wright
Mark Wright
GHGawon Han
Gawon Han
JYJihyun Yun
Jihyun Yun
EYEugene Yip
Eugene Yip
ZGZsolt Gabos
Zsolt Gabos
KWKeith Wachowicz
Keith Wachowicz
Objective. To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications. Approach. Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting. Main results. It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation. Significance. This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).

1 March 2021 in Brachytherapy
Verified
Journal Article
Closed access
GHGawon Han
Gawon Han
MLMatthew Larocque
Matthew Larocque
EWEzekiel Weis
Ezekiel Weis
GMGeetha Menon
Geetha Menon

19 May 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
GHGawon Han
Gawon Han
AEArun Elangovan
Arun Elangovan
JWJordan Wong
Jordan Wong
AWAsmara Waheed
Asmara Waheed
KWKeith Wachowicz
Keith Wachowicz
BFB. Gino Fallone
B. Gino Fallone
Real-time tumor-tracked radiotherapy with a linear accelerator-magnetic resonance (linac-MR) hybrid system requires accurate tumor delineation at a fast MR imaging rate. Various autocontouring methods have been previously evaluated against “gold standard” manual contours by experts. However, manually drawn contours have inherent intra- and inter-observer variations. We aim to quantify these variations and evaluate our tumor-autocontouring algorithm against the manual contours. Ten liver, ten prostate, and ten lung cancer patients were scanned using a 3 tesla (T) magnetic resonance imaging (MRI) scanner with a 2D balanced steady-state free precession (bSSFP) sequence at 4 frames/s. Three experts manually contoured the tumor in two sessions. For autocontouring, an in-house built U-Net-based autocontouring algorithm was used, whose hyperparameters were optimized for each patient, expert, and session (PES). For evaluation, (A) Automatic vs. Manual and (B) Manual vs. Manual contour comparisons were performed. For (A) and (B), three types of comparisons were performed: (a) same expert same session, (b) same expert different session, and (c) different experts, using Dice coefficient (DC), centroid displacement (CD), and the Hausdorff distance (HD). For (A), the algorithm was trained using one expert’s contours and its autocontours were compared to contours from (a)–(c). For Automatic vs. Manual evaluations (Aa–Ac), DC = 0.91, 0.86, 0.78, CD = 1.3, 1.8, 2.7 mm, and HD = 3.1, 4.6, 7.0 mm averaged over 30 patients were achieved, respectively. For Manual vs. Manual evaluations (Ba–Bc), DC = 1.00, 0.85, 0.77, CD = 0.0, 2.1, 2.8 mm, and HD = 0.0, 4.9, 7.2 mm were achieved, respectively. We have quantified the intra- and inter-observer variations in manual contouring of liver, prostate, and lung patients. Our PES-specific optimized algorithm generated autocontours with agreement levels comparable to these manual variations, but with high efficiency (54 ms/autocontour vs. 9 s/manual contour).