25 April 2011 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KDKarel Draxler
Karel Draxler
RSRenata Styblikova
Renata Styblikova
JHJan Hlavacek
Jan Hlavacek
RPRadek Procházka
Radek Procházka
This paper describes the calibration of Rogowski coils with an integrator for current measurement in the current range of up to 30 kA, at mains frequency. A current loop of ten turns with a current of 3 kA was used for calibration. The magnetic field generated in this way differs from the field of one turn placed at the center and passed with a current of 30 kA. The influence of the unevenness of winding and the cross section of the Rogowski coil may cause a calibration error when using a current loop. The difference in the results between using a current loop and one turn, and the measurement uncertainties are given here. Calculations of the mutual inductances of typical Rogowski coils and their uncertainties are presented in the Appendix.

2 February 2015 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
RPRadek Procházka
Radek Procházka
JHJan Hlavacek
Jan Hlavacek
KDKarel Draxler
Karel Draxler
Power and energy measurements in smart grids require a measurement system capable of performing signal processing at the higher harmonic frequencies that are present in power grids. For the calibration process of instrument voltage transformers, or high-voltage dividers, it is necessary to have a high-voltage source with an appropriate frequency range. The fundamental element of such a source is the output high-voltage transformer operating at a nominal voltage of 10 kV and in the frequency range from 200 Hz up to 10 kHz. The output current is assumed to be lower than 20 mA. This paper focuses on the design and realization of the magnetic circuit of the transformer described above. Trafoperm, ferrite or nanocrystalline materials can be used for the frequency range considered here. Ferrite materials usually reach saturation at a magnetic flux density of 0.2 T with very low permeability values, while trafoperm material usually suffers from unacceptable power losses in higher frequency areas. This is the main reason why these materials are not suitable for use in a wide range of frequencies, and some combined magnetic cores must be used. The proposed solution is based on magnetic cut C type cores made from nanocrystalline alloy (VITROPERM 500), which behaves better in the frequency range under consideration. The magnetic parameters of this material were measured and compared with trafoperm, and then, the 10 kV high-voltage transformer was designed and manufactured.

17 August 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MKMartin Knenicky
Martin Knenicky
RPRadek Procházka
Radek Procházka
JHJan Hlavacek
Jan Hlavacek
OSOndrej Sefl
Ondrej Sefl
Switching processes of voltage source converters can emit significant high-frequency distortions of frequencies between 5 to 20 kHz. Furthermore, the distortions can partly propagate from the place of their origin into a medium voltage system via capacitive coupling of power transformers. The origin, parameters, and propagation process of distortions were clarified by a numerical simulation of a 1-MW photovoltaic power plant connected to the medium voltage distribution grid. The determined results provided input data for the following accelerated aging test setup. The main idea behind the accelerated aging tests was to confirm the effect of the high-frequency distortions on the degradation rate of cable insulation systems. The tests were performed on cable samples, with terminations mounted on each end, which were split into three groups. The first sample group was stressed by increased power frequency voltage and by maximum operating temperature. The second group was stressed similarly, but with superposed high-frequency distortions present. The last group was not stressed to provide reference values for the other groups. Partial discharge, dissipation factor, and breakdown voltage measurements were carried out on both aged groups. The results indicate that cable insulation degradation progresses faster under power frequency voltage with superposed high-frequency distortions.

21 December 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
RPRadek Procházka
Radek Procházka
JHJ. Hlavacek
J. Hlavacek
KDK. Draxler
K. Draxler
The objective of this paper is to propose and to validate the behavior of an impulse current transformer with a nanocrystalline alloy toroidal core. The purpose of this transformer is to measure a current square waveform with a fundamental harmonic frequency of 25 kHz. Current ratio 1:1 and the real burden are assumed, and the transformer will operate in an electric power system at voltage levels up to 25 kV. These special requirements are typical for applications such as photovoltaic power plants, where the currents in high voltage inverters need to be measured. These inverters usually use the principle of pulse width modulation (PWM), and are able to convert from a low voltage direct current to high voltage alternating current. In this way, the electric power can be supplied directly to the high voltage distribution grid without the use of a power transformer.

13 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAwad Abdullah Almehdhar
Awad Abdullah Almehdhar
RPRadek Procházka
Radek Procházka
Partial discharge (PD) analysis is critical for diagnosing insulation degradation in high-voltage equipment. While conventional methods struggle with multi-source PD classification due to signal overlap and noise, this study proposes a hybrid approach combining five time–frequency analysis (TFA) techniques with deep learning (GoogLeNet for simulation, ResNet50 for experiments). PD data are generated through Finite Element Method (FEM) simulations and validated via laboratory experiments. The Scatter Wavelet Transform (SWT) achieves 96.67% accuracy (F1-score: 0.967) in simulation and perfect 100% accuracy (F1-score: 1.000) in experiments, outperforming other TFAs like HHT (70.00% experimental accuracy). The Wigner–Ville Distribution (WVD) also shows strong experimental performance (94.74% accuracy, AUC: 0.947), though its computational complexity limits real-time use. These results demonstrate the SWT’s superiority in handling real-world noise and multi-source PD signals, providing a robust framework for insulation diagnostics in power systems.

1 February 2015 in Electric Power Systems Research
Verified
Journal Article
Closed access
EEEmad H. El-Zohri
Emad H. El-Zohri
HZH. Ziedan
H. Ziedan
RPRadek Procházka
Radek Procházka