Deyang Yu

Prof. Dr. Deyang Yu

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2017 in Physical Review A
Verified
Journal Article
Closed access
PDF file
CSCaojie Shao
Caojie Shao
DYDeyang Yu
Deyang Yu
XCXiaohong Cai
Xiaohong Cai
XCXi Chen
Xi Chen
KMKun Ma
Kun Ma
ZYZhihu Yang
Zhihu Yang
X-ray spectra of K-shell hollow krypton atoms produced in single collisions with 52–197-MeV/u Xe54+ ions are measured in a heavy-ion storage ring equipped with an internal gas-jet target. Energy shifts of the Kα1,2s, Kα1,2h,s, and Kβ1,3s transitions are obtained. Thus the average number of the spectator L vacancies presented during the x-ray emission is deduced. From the relative intensities of the Kα1,2s and Kα1,2h,s transitions, the ratio of K-shell hollow krypton to singly K-shell ionized atoms is determined to be 14%–24%. In the considered collisions, the K vacancies are mainly created by the direct ionization which cannot be calculated within the perturbation descriptions. The experimental results are compared with a relativistic coupled-channel calculation performed within the independent particle approximation.

1 April 2009 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
WWWei Wang
Wei Wang
DQDejun Qi
Dejun Qi
DYDeyang Yu
Deyang Yu
MZMingwu Zhang
Mingwu Zhang
FRFangfang Ruan
Fangfang Ruan
XCXiaohong Cai
Xiaohong Cai
The transmission of low-energy (1100eV-1500eV) electrons through SiO 2 tube was investigated, the distribution of transmitted beam current was observed. Results indicate that the intensity of transmitted electrons is proportional to the relative incident beam intensity and the angular divergence of the transmitted electrons is reduced when incident energy increased.

22 August 2007 in Physical Review A
Verified
Journal Article
Closed access
PDF file
DYDeyang Yu
Deyang Yu
XCXiaohong Cai
Xiaohong Cai
RLRongchun Lu
Rongchun Lu
FRFangfang Ruan
Fangfang Ruan
CSCaojie Shao
Caojie Shao
ZLZhaoyuan Liu
Zhaoyuan Liu
The collisions of the isocharged sequence ions of q=6 (C6+, N6+, O6+, F6+, Ne6+, Ar6+, and Ca6+), q=7 (F7+, Ne7+, S7+, Ar7+, and Ca7+), q=8 (F8+, Ne8+, Ar8+, and Ca8+), q=9 (F9+, Ne9+, Si9+, S9+, Ar9+, and Ca9+) and q=11 (Si11+, Ar11+, and Ca11+) with helium at the same velocities were investigated. The cross-section ratios of the double-electron transfer (DET) to the single-electron capture (SEC) σDET∕σSEC and the true double-electron capture (TDC) to the double-electron transfer σTDC∕σDET were measured. It shows that for different ions in an isocharged sequence, the experimental cross-section ratio σDET∕σSEC varies by a factor of 3. The results confirm that the projectile core is another dominant factor besides the charge state and the collision velocity in slow (0.35−0.49v0; v0 denotes the Bohr velocity) highly charged ions (HCIs) with helium collisions. The experimental cross-section ratio σDET∕σSEC is compared with the extended classical over-barrier model (ECBM) [A. Bárány et al., Nucl. Instrum. Methods Phys. Res. B 9, 397 (1985)], the molecular Coulombic barrier model (MCBM) [A. Niehaus, J. Phys. B 19, 2925 (1986)], and the semiempirical scaling laws (SSL) [N. Selberg et al., Phys. Rev. A 54, 4127 (1996)]. It also shows that the projectile core properties affect the initial capture probabilities as well as the subsequent relaxation of the projectiles. The experimental cross-section ratio σTDC∕σDET for those lower isocharged sequences is dramatically affected by the projectile core structure, while for those sufficiently highly isocharged sequences, the autoionization always dominates, hence the cross-section ratio σTDC∕σDET is always small.

1 November 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DYDeyang Yu
Deyang Yu
JLJunliang Liu
Junliang Liu
YXYingli Xue
Yingli Xue
MZMingwu Zhang
Mingwu Zhang
XCXiaohong Cai
Xiaohong Cai
XLXin Li
Xin Li
A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O3+ ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

1 March 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JLJunliang Liu
Junliang Liu
DYDeyang Yu
Deyang Yu
FRFangfang Ruan
Fangfang Ruan
YXYingli Xue
Yingli Xue
WWWei Wang
Wei Wang
We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar7+ ion beam.

4 February 2011 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
DYDeyang Yu
Deyang Yu
YXYingli Xue
Yingli Xue
CSCaojie Shao
Caojie Shao
ZSZhangyong Song
Zhangyong Song
RLRongchun Lu
Rongchun Lu
XCXiaohong Cai
Xiaohong Cai