Cross-linked polyethylene (XLPE) carries a high fire risk. In this paper, a cone calorimeter is used to carry out radiation ignition experiments, and the heat release rate (HRR), mass loss rate (MLR) and other combustion parameters of XLPE cables under three kinds of radiation intensity are measured. By comparing the ignition time and HRR of samples under different conditions, the following conclusions are drawn: (1) The ignition time of XLPE cables decreases significantly with the increase in external thermal radiation intensity. The critical ignition heat flux (CHF) is about 16.24 kW/m2. (2) The HRR curve of XLPE is consistent with the characteristics of hot, thick material. The HRR rises rapidly to the first peak after ignition and then rapidly decreases. Then, it slowly rises to the second peak. Finally, it slowly decays until the combustion stops. (3) The first peak values of HRR of XLPE under different radiation intensities are almost the same. The time for the second peak of HRR is shorter, and the value is larger with the increase in external thermal radiation intensity. (4) The cable ignition model is established, which can simulate the cable ignition time well under different radiant heat flow conditions. (5) Based on the mathematical model, the ignition time trend with the thickness of sheath layer and conductive core layer as variables is deduced.
Most previous works concentrated on burning characteristics of pool fire using common fuels such as heptane, propane, biodiesel, and diesel, whereas burning characteristics for transformer oil are barely involved, although transformer oil is arguable of more practical importance in power system. This study performed a series of pool fire experiments using transformer oil to study the burning characteristics in open and confined spaces. Three fuel thicknesses and five initial temperatures are changed in open space. The essential parameters of mass loss rate, flame height, and fire plume temperature are obtained and analyzed. Moreover, three oil pool diameters are varied in a chamber. The main conclusions are summarized as follows: the variations of mass loss rate, flame height, and fire plume temperature not only obviously increase as the fuel thickness increases from 0.5 cm to 1.0 cm, but also insignificantly increase as the fuel thickness changes from 1.0 cm to 2.0 cm. The mass loss rate is less sensitive to the initial temperature of transformer oil, but the flame height and fire plume temperature significantly rise with the initial temperature. Moreover, the modified models to predict the flame height and fire plume temperature for 25°C initial temperature conditions are proposed, but the fitting coefficients are obviously different from that for common liquid fuels. The flame height in confined space is higher and will rapidly increase to the maximum, then decreases, and tends to be stable, which is obviously different from the oil pool fire burning in open space. In addition, the phenomenon of burning blast and the ignition of the adjacent oil pool will be observed with a high‐temperature ignition source and a certain high temperature in a chamber under 30 cm oil pool diameter, which will not be recorded in 15 cm and 20 cm.
17 May 2023 in Case Studies in Thermal Engineering
Electricity is an important energy supply for industry, and long‐distance transmission in China mainly relies on cable tunnels, while cable tunnel fires occur frequently. A 1:1 scale tunnel model with a length of 20 m, a width of 2.5 m, and a height of 2.5 m was used to conduct experimental research on the temperature field of the ceiling of a high‐voltage fine water mist suppression cable tunnel. The article conducted experimental research on parameters, such as nozzle pressure, nozzle position, and longitudinal ventilation speed in high‐pressure water mist systems using n‐hexane as the ignition source. The results indicate that the high‐pressure water mist system can effectively reduce the ceiling temperature during cable tunnel fires. When the mechanical smoke evacuation system is activated, it leads to a reduction in the overall temperature within the tunnel. When the mechanical smoke extraction system is integrated with the high‐pressure water mist system, therefore, it is feasible to integrate the high‐pressure water mist system with the mechanical smoke exhaust system in engineering applications.