José Antonio Lasalde-Ramirez

Mr. José Antonio Lasalde-Ramirez


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
William E García-RodríguezWilliam E García-Rodríguez
William E García-Rodríguez
KEKarla Andrea Echeverria-Altamar
Karla Andrea Echeverria-Altamar
JLJosé Antonio Lasalde-Ramirez
José Antonio Lasalde-Ramirez
PRPedro Resto
Pedro Resto
This study investigates the fabrication of laser-scribed graphene (LSG) electrodes on polyimide substrates using a CO2 laser cutter for label-free L-Histidine detection in artificial sweat. Two-level full factorial and central composite designs were employed to optimize critical manufacturing parameters, including laser speed, power, and electrode width. Electrochemical characterization using cyclic voltammetry with K3Fe[CN]6 demonstrated superior LSG electrode performance compared to standard glassy carbon electrodes, exhibiting a 702 ± 62% higher oxidation current peak at 0.56 mM K3Fe[CN]6 in 0.1 M KCl. We successfully demonstrated the label-free electrochemical detection of L-Histidine in artificial sweat using these LSG electrodes. The results show a linear relationship (R2 = 0.987) between current peak and L-Histidine concentration within the 8.3 mM to 50 mM range, demonstrating high sensitivity towards L-Histidine. These findings highlight the potential of this optimized LSG electrode fabrication approach for developing high-performance, user-friendly, and disposable wearable biosensors for real-time and non-invasive health monitoring applications in sweat analysis.

3 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
William E García-RodríguezWilliam E García-Rodríguez
William E García-Rodríguez
JLJosé Antonio Lasalde-Ramirez
José Antonio Lasalde-Ramirez
ENEduardo Nicolau
Eduardo Nicolau
KEKarla Andrea Echeverria-Altamar
Karla Andrea Echeverria-Altamar
PRPedro Resto
Pedro Resto
This study investigates the fabrication of laser-scribed graphene (LSG) electrodes on polyimide substrates using a CO2 laser cutter for label-free L-histidine detection in artificial sweat. Two-level full factorial and central composite designs were employed to optimize critical manufacturing parameters, including laser speed, power, and electrode width. Electrochemical characterization using cyclic voltammetry with K3Fe[CN]6 demonstrated superior LSG electrode performance compared to standard glassy carbon electrodes, exhibiting a 702 ± 62% higher oxidation current peak at 0.56 (mM) K3Fe[CN]6 in 0.1 M KCl. We successfully demonstrated the label-free electrochemical detection of L-histidine in artificial sweat using these LSG electrodes. The results show a linear relationship (R2 =0.987) between current peak and L-histidine concentration within the 8.3 (mM) to 50 (mM) range, demonstrating high sensitivity towards L-histidine. These findings highlight the potential of this optimized LSG electrode fabrication approach for developing high-performance, user-friendly, and disposable wearable biosensors for real-time, and non-invasive health monitoring applications in sweat analysis.