Greta Gaggiato

Dr. Greta Gaggiato


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2025 in Cancers
Verified
Journal Article
Open access
PDF file
Giuseppe ReitanoGiuseppe Reitano
Giuseppe Reitano
ATArianna Tumminello
Arianna Tumminello
CPCarlo Prevato
Carlo Prevato
ACAnna Cacco
Anna Cacco
GGGreta Gaggiato
Greta Gaggiato
FZFabio Zattoni
Fabio Zattoni
Introduction: The Da Vinci Single-Port (DV-SP) system emerged in 2018 but there is limited evidence on its use and perioperative outcomes for robot-assisted adrenalectomy (RAA). Methods: A systematic search was performed through PubMed, Scopus, Ovid, and WoS in December 2024. A PICO framework was used. Population: adult patients with adrenal masses; Intervention: DV-SP RAA; Outcomes: feasibility, reproducibility and safety of DV-SP RAA. A total of five retrospective studies involving 342 patients were included. The quantitative analysis was conducted using a random-effect model or a fixed-effect model as appropriate. A risk of bias assessment for non-randomized comparative studies and case series was performed. Results: The pooled mean operative time was 92.5 min (95% confidence interval [CI] 71.2, 113.9, p I2 = 0%, four studies), and the mean estimated blood loss (EBL) was 26.5 mL (95%CI −8.1, 61.2, I2 = 98.2%, three studies). Most of the procedures were completed with a single incision, though some required additional port placement, with a proportion of 9% (95%CI 0, 29, I2 = 71.7%, five studies). Perioperative complications were rare (0%, 95% CI 0, 4, I2 = 0%, five studies). Two studies comparing DV-SP and DV multi-port (MP) found no significant differences in complications. One study compared DV-SP RAA to DV Si or Xi single-access procedures. DV-SP showed improved operative techniques and better cosmetic outcomes. Limitations of this study are small sample size and potential selection bias due to smaller masses in the DV-SP RAA group. Conclusions: DV-SP RAA is a promising approach, offering reduced operative time, low EBL, and excellent cosmetic results. This study shows that DV-SP RAA seems reproducible, feasible, and safe. Limitation of the included studies are small sample size and selection bias, which limits the generalizability of the results. Randomized comparative studies between DV-SP and MP RAA are needed to further validate these findings.