This paper discusses Dissolved Gas Analysis (DGA) in transformer oil from two 69/24 kV 24/32 MVA installed in urban areas. By detecting unusual increasing gas, then transformer oil samples were collected frequently according to Standards. First transformer was failed by inside short circuit. All loads were transfer to second transformer. The risk of failure on last transformer is very high. Standards used for DGA interpretation is IEEE C57.104. Evaluation of fault type used Key gas method, Doernenburg ratio, Rogers ratio and Duval Triangle.

5 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NCNaris Chattranont
Naris Chattranont
SWSakhon Woothipatanapan
Sakhon Woothipatanapan
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
Dissolved gas analysis (DGA) is one of the transformer testing methods that has been widely used for a long time because it does not require the transformer to be offline for testing. The inspection can be conducted while the transformer is operating normally, and it is cost-effective. In research on fault severity, thermodynamic theory has been applied to find the energy index of the hydrocarbon gases generated by faults, CH4, C2H6, C2H4 and C2H2, referred to as the Normalised Energy Intensity (NEI). This study examines the application of the Positive Cumulative Sum of Difference (CUSUM) method to hydrocarbon NEI and carbon dioxide NEI for fault severity assessment. The study demonstrates the effectiveness of this approach by means of case studies on the basis of DGA results from two steel plants. In the case of NEI from hydrocarbon gases (NEIHC), the positive CUSUM is compared with the NEI, the NEI score, and the cumulative NEI. In the case of NEI from carbon oxide gases (NEICO), Positive CUSUM is compared with NEI and the ratio of CO2 to CO. It was found that Positive CUSUM for NEIHC is a much better indicator of the severity of defects than the NEI, the NEI score, and the cumulative NEI. In contrast, Positive CUSUM for NEICO gave excessively high values. However, combining NEI with the CO2/CO ratio gave better monitoring results. Therefore, from an online DGA perspective, Positive CUSUM can be used to effectively monitor fault severity.

6 December 2023
Verified
Conference Paper
Closed access
NCNaris Chattranont
Naris Chattranont
TMTanit Menaneatra
Tanit Menaneatra
JKJutanon Kaewmanee
Jutanon Kaewmanee
Transformers are essential devices in the distribution system. If the transformer is damaged, It will cause a prolonged power outage and affect many customers. Therefore, inspecting and analyzing the transformer’s condition for maintenance planning is essential. Dissolved gas analysis is extensive use because sampling of transformer oil for analysis can be carried out without shutting down the transformer and at a low cost. This paper discusses the application of machine learning methods to classify fault types from the results of dissolved gas analysis. The significant gases dissolved in transformer oil are Hydrogen (H 2 ), Methane (CH 4 ), Ethane (C 2 H 6 ), Ethylene (C 2 H 4 ), and Acetylene (C 2 H 2 ). Fault type analysis using Classification Machine Learning Algorithms such as Decision Tree, Naive Bayes, k-nearest Neighbor, and Support Vector Machine compared to Ensemble Machine Learning Algorithms such as Bootstrap Aggregation (Bagging), Random Forest, and Adaboost. Ensemble Machine Learning Algorithms make prediction results more accurate than Classification Machine Learning algorithms.