This paper presents a method of enhancing voltage and power stability in a distribution system with the photovoltaic benefits of battery energy storage. The objective is to use photovoltaic-distributed generation and a battery energy storage system in order to reduce power loss to a minimum and generate a voltage up to or above 0.95 p.u, which is the voltage standard in Thailand. This paper used MATLAB (Version R2024b-acdemic use) to conduct test experiments, and the system for the case studies is an IEEE 33-bus radial distribution system. There are five study cases in this paper. Case 1 is before the installation of the photovoltaic and battery energy storage system. Case 2 is the installation of the photovoltaic-distributed generator in four buses. Case 3 is the installation of the photovoltaic-distributed generator in only one bus. Case 4 is the installation of the photovoltaic distributed generator in two buses that have the most voltage drop. Case 5 is the installation of the photovoltaic-distributing generator in four buses and the battery energy storage system in two buses. The results show that Case 5 is the best because the voltage drop is never below 0.95 per unit or below the lowest power loss.
This paper presents an analysis of shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop systems. The objective was to evaluate the amount of carbon credits generated and their returns. The study includes an economic analysis and a comparison of the economic outcomes with and without the consideration of carbon credits from 149.80 kWp and 25.68 kWp photovoltaic rooftop systems. The study evaluated the amount of electrical energy produced by the photovoltaic rooftop systems, estimated using the PVsyst program version 7.3.1, at a factory in Pathum Thani Province, Thailand. The economic indices analyzed in this study include the payback period, net present value (NPV), benefit–cost ratio (B/C ratio), and internal rate of return (IRR). The analysis is divided into four case studies: Case 1 is the base case, and Cases 2, 3, and 4 consider carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include the financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. In Cases 2, 3, and 4, the economic indices analyzed are the economic internal rate of return (EIRR), the economic net present value (ENPV), the B/C ratio, and the payback period. This paper outlines a new economic calculation approach that incorporates carbon credits produced by photovoltaic rooftop systems, which helps achieve break-even points more quickly. It also discusses the application of carbon credits in conjunction with renewable energy.
This paper considers an application of Newton's optimal power flow to the solution of the secondary voltage/reactive power control in power system. This procedure is based on the sensitivity theory applied to the determination of zones for the secondary voltage/ reactive power control and corresponding reduced set of regulating sources, whose reactive outputs represent control variables in the optimal power flow program. PSO is applied to solve the OPF problem for optimal power flow the optimal power flow program output becomes a schedule to be used by operators in the process of OPF-PSO (Optimal Power Flow - Particle swarm optimization) PSO applied to optimal reactive power dispatch is evaluated on an IEEE 30-bus power system. The optimization strategy is general and can be used to solve other power system optimization problems as well.
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be in two parts: the first part arises from power outages, which lead to lost sales, estimated opportunities, and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and large-scale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.
This research aims to present a study of the effects of the Tesla transformer in order to find the proper dimensions. We created a design of the Tesla transformer to reduce the high-voltage electric field-stress problem that happens between primary winding and secondary winding. Because the Tesla transformer is used to induce voltage between these two windings through the air, problems with insulation occur. The winding that has space is dielectric; while there is high voltage in a transformer, it causes flashover voltage between the high-voltage winding and low-voltage winding, which damages the transformer and other devices. Research process: Research was conducted to study the laydown model (positioning) of the two windings in the transformer. By considering this, we induced a proper Tesla transformer that was reproduced by using the FEMLAB program. Moreover, we compared the Tesla transformer reproduction, which created a voltage of 120 kV and a frequency of 120 kHz. The result from the comparison is a proper laydown position of the primary winding and voltage, which has been designed without the flashover. The whorl coil has to be wound at a 60-degree angle relative to the floor and can induce more voltage than other models. The voltage and corresponding electric field stress were measured for the primary winding at various angles relative to the floor (0-, 30-, 45-, 60-, and 90-degree angles) to determine the configuration. The results from the reproduction using the FEMLAB program and testing demonstrated that no flashover occurred between the high-voltage winding to the low-voltage winding when the primary winding was positioned at a 60-degree angle.
This paper presents shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop system. The objective was to evaluate the amount and returns of carbon credits. Economic analysis, and comparison of economic analysis with and without consideration of carbon credits from a 149.80 kWp, and 25.68 kWp photovoltaic rooftop system. This study evaluated the amount of electrical energy produced by a photovoltaic rooftop system estimated from the PVsyst program of the factory in Pathum Thani Province, Thailand. The economic indices that the researcher analyzed include the payback period, net present value (NPV), benefit cost ratio (B/C ratio), internal rate of return (IRR). It is divided into four cases studies: Case 1 is the base case, and Cases 2, 3, and 4 are considered carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. The economic indices analyzed in Cases 2, 3, and 4 are the economic internal rate of return (EIRR), economic net present value (ENPV), B/C ratio, payback periods, respectively. This paper outlines a new economic calculation approach that considers carbon credits produced by photovoltaic rooftop system to reach break-even points more quickly, and the application of carbon credits in conjunction with renewable energy.