Katheryn Jo Allyn

Mrs. Katheryn Jo Allyn

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2017 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
JCJohn C. Cagle
John C. Cagle
PRPer G. Reinhall
Per G. Reinhall
KAKatheryn Jo Allyn
Katheryn Jo Allyn
JMJake McLean
Jake McLean
PHPaul Hinrichs
Paul Hinrichs
JSJoan E. Sanders
Joan E. Sanders

1 April 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JSJoan E. Sanders
Joan E. Sanders
RYRobert T Youngblood
Robert T Youngblood
BHBrian J Hafner
Brian J Hafner
JCJohn C Cagle
John C Cagle
JMJake McLean
Jake McLean
KAKatheryn Jo Allyn
Katheryn Jo Allyn
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8mm (∼6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4 weeks. Participants' gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measured as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort score, and self-reported utility. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study.

1 January 2012 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
JSJoan E. Sanders
Joan E. Sanders
DHDaniel S. Harrison
Daniel S. Harrison
KAKatheryn Jo Allyn
Katheryn Jo Allyn
TMTimothy R. Myers
Timothy R. Myers
MCMarcia A. Ciol
Marcia A. Ciol
ETElaine C. Tsai
Elaine C. Tsai
The purpose of this research was to investigate the influence of sock addition and removal on residual-limb fluid volume in people using prosthetic limbs. We used bioimpedance analysis to measure residual-limb extracellular fluid volume on 28 transtibial amputee subjects during 30 min test sessions. Upon addition of a one-ply polyester sock, residual-limb fluid volume changes ranged from -4.0% to 0.8% (mean -0.9 +/- 1.3%) of the initial limb fluid volume. Changes for sock removal ranged from -1.2% to 2.8% (mean 0.5 +/- 0.8%). Subjects who reduced in fluid volume with both addition and removal of a sock and subjects with high positive ratios between the fluid-volume loss upon sock addition and gain upon sock removal (high add/remove [AR] ratios) tended to have arterial disease, were obese, and were smokers. Subjects with low positive AR ratios, subjects who increased in fluid volume both with sock addition and removal, and a single subject who increased in fluid volume with sock addition and decreased with sock removal tended to be nonsmokers and either individuals in good health without complications or individuals without arterial problems. Results are relevant for the anticipation of limb volume changes during prosthetic fitting and toward the design of adjustable-socket technologies.

1 January 2011 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
JSJoan E. Sanders
Joan E. Sanders
DHDaniel S. Harrison
Daniel S. Harrison
TMTimothy R. Myers
Timothy R. Myers
KAKatheryn Jo Allyn
Katheryn Jo Allyn
Bioimpedance analysis was used to measure the residual limb fluid volume of seven transtibial amputee subjects using elevated vacuum sockets and nonelevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30 min test session were less for elevated vacuum than for suction. Numerous variables, including the time of day that data were collected, soft tissue consistency, socket-to-limb size and shape differences, and subject health, may have affected the results and had an equivalent or greater effect on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in the study design of future investigations on the effects of elevated vacuum on residual limb volume.

1 January 2014 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
JSJoan E. Sanders
Joan E. Sanders
JCJohn C Cagle
John C Cagle
KAKatheryn Jo Allyn
Katheryn Jo Allyn
DHDaniel S Harrison
Daniel S Harrison
MCMarcia A Ciol
Marcia A Ciol
The purpose of this research was to determine how fluid volume changes in the residual limbs of people with transtibial amputation were affected by activity during test sessions with equal durations of resting, standing, and walking. Residual limb extracellular fluid volume was measured using biompedance analysis in 24 participants. Results showed that all subjects lost fluid volume during standing with equal weight-bearing, averaging a loss rate of -0.4%/min and a mean loss over the 25 min test session of 2.6% (standard deviation [SD] 1.1). Sixteen subjects gained limb fluid volume during walking (mean gain of 1.0% [SD 2.5]), and fifteen gained fluid volume during rest (mean gain of 1.0% [SD 2.2]). Walking explained only 39.3% of the total session fluid volume change. There was a strong correlation between walk and rest fluid volume changes (-0.81). Subjects with peripheral arterial disease experienced relatively high fluid volume gains during sitting but minimal changes or losses during sit-to-stand and stand-to-sit transitioning. Healthy female subjects experienced high fluid volume changes during transitioning from sit-to-stand and stand-to-sit. The differences in fluid volume response among subjects suggest that volume accommodation technologies should be matched to the activity-dependent fluid transport characteristics of the individual prosthesis user.

1 February 2019 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
PDF file
RYRobert Tyler Youngblood
Robert Tyler Youngblood
BHBrian J Hafner
Brian J Hafner
KAKatheryn Jo Allyn
Katheryn Jo Allyn
JCJohn C Cagle
John C Cagle
PHPaul Hinrichs
Paul Hinrichs
JSJoan E. Sanders
Joan E. Sanders
The volume of a prosthesis user’s residual limb changes during the day and may affect the fit of the prosthesis. These changes must be managed by the user to prevent discomfort, skin breakdown, and falls. The objectives were to test how activity, time of day, and intermittent doffing affected residual limb fluid volume in people with transtibial amputation. Standardized, repeated measure (A-B-A) out-of-laboratory protocol. Participants with transtibial amputation completed three 6-h test sessions. Two sessions served as controls (A protocol) during which participants left their prosthesis donned, and one session was an intervention (B protocol) where participants doffed their prosthesis twice for 20 min during the 6 h of testing. Within-socket fluid volume was measured using a custom portable bioimpedance analysis system. A total of 13 participants completed the study. The rate of limb fluid volume loss was higher early in the session compared with late in the session. Participants experienced less fluid volume loss during high activity than low activity. Socket users with pin suspension experienced less posterior fluid volume loss when they intermittently doffed their prosthesis. Intermittent doffing did not benefit limb fluid volume of mechanical vacuum and suction suspension users. High activity may reduce fluid volume loss compared with low activity. Intermittent doffing may provide volume accommodation for transtibial prosthesis users with pin suspension. Prosthetists should query their patients about the intensity of activity they conduct when advising them on limb volume management. Patients using sockets with pin suspension may be able to offset limb fluid volume loss by periodically doffing the prosthesis.