Ji-Uk Yoon

Prof. Dr. Ji-Uk Yoon


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2018 in Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
JYJi-Uk Yoon
Ji-Uk Yoon
CBChul-Woo Baek
Chul-Woo Baek
HKHyung Joon Kim
Hyung Joon Kim
EKEun-Jung Kim
Eun-Jung Kim
GBGyeong-Jo Byeon
Gyeong-Jo Byeon

23 January 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JKJae-Young Kwon
Jae-Young Kwon
BPBong-Soo Park
Bong-Soo Park
YKYong-Ho Kim
Yong-Ho Kim
CKCheul- Hong Kim
Cheul- Hong Kim
JYJi-Uk Yoon
Ji-Uk Yoon
The proliferation, differentiation, and migration of keratinocytes are essential in the early stages of wound healing. Hypoxia-Reoxygenation (H/R) injury to keratinocytes can occur in various stressful environments such as surgery, trauma, and various forms of ulcers. The effects of remifentanil on human keratinocytes under hypoxia-reoxygenation have not been fully studied. Therefore, we investigated the effects of remifentanil on the proliferation, apoptosis, and autophagic activation of human keratinocytes during hypoxic-reoxygenation. Human keratinocytes were cultured under 1% oxygen tension for 24 h. The cells were then treated with various concentrations of remifentanil (0.01, 0.1, 0.5, and 1 ng/mL) for 2 h. Thereafter, the cells were reoxygenated for 12 h at 37°C. We measured cell viability via MTT assay. Using quantitative real-time PCR and western blot analysis, we measured the expression levels of proteins associated with apoptosis and autophagy. Quantification of apoptotic cells was performed using flow cytometer analysis and autophagic vacuoles were observed under a fluorescence microscope. Remifentanil treatment brought about an increase in the proliferation of human keratinocytes damaged by hypoxia-reoxygenation and decreased the apoptotic cell death, enhancing autophagic activity. However, the autophagy pathway inhibitor 3-MA inhibited the protective effect of remifentanil in hypoxia-reoxygenation injury. In conclusion, the current study demonstrated that remifentanil treatment stimulated autophagy and reduced apoptotic cell death in a hypoxia-reoxygenation model of human keratinocytes. Our results provide additional insights into the relationship between apoptosis and autophagy.

1 January 2015 in International Journal of Medical Sciences
Verified
Journal Article
Open access
SBSeung-Wan Baik
Seung-Wan Baik
BPBong-Soo Park
Bong-Soo Park
YKYong-Deok Kim
Yong-Deok Kim
CKCheul-Hong Kim
Cheul-Hong Kim
JYJi-Uk Yoon
Ji-Uk Yoon
Background: Ischemia-reperfusion of bone occurs in a variety of clinical conditions, such as orthopedic arthroplasty, plastic gnathoplasty, spinal surgery, and amputation. Usually, cellular models of hypoxia-reoxygenation reflect in vivo models of ischemia-reperfusion. With respect to hypoxia-reoxygenation conditions, the effects of remifentanil on osteogenesis have received little attention. Therefore, we investigated the effects of remifentanil on the proliferation and differentiation of osteoblasts during hypoxic-reoxygenation.

2 March 2017 in Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
JYJi-Uk Yoon
Ji-Uk Yoon
CPChul-Gue Park
Chul-Gue Park
BPBong-Soo Park
Bong-Soo Park
EKEun-Jung Kim
Eun-Jung Kim
GBGyeong-Jo Byeon
Gyeong-Jo Byeon

26 December 2022 in Pain Research and Management
Verified
Journal Article
Open access
PDF file
HKHye-Jin Kim
Hye-Jin Kim
JBJi-Hye Baek
Ji-Hye Baek
SPSeyeon Park
Seyeon Park
JYJi-Uk Yoon
Ji-Uk Yoon
GBGyeong-Jo Byeon
Gyeong-Jo Byeon
SSSang-Wook Shin
Sang-Wook Shin
Background. Despite the clinical effectiveness of the programmed intermittent bolus (PIB) method for epidural analgesia, evidence for this method in continuous interscalene brachial plexus block (CIBPB) is unclear. This study aimed to investigate the pain relief effect after arthroscopic shoulder surgery according to the administration method by comparing the PIB and continuous infusion methods among the administration methods of local anesthetics. Methods. Sixty-four patients aged >19 years scheduled for elective arthroscopic shoulder surgery were enrolled and divided into two groups. Ultrasound-guided CIBPB was performed to control postoperative pain. The infusion pump was programmed so that 0.2% ropivacaine was continuously injected at 1.1 mL/h in group A, whereas in group B, 0.1 mL/h was continuously injected and 4 mL was periodically injected at 4 h intervals. In both groups, a further infusion of 4 mL of 0.2% ropivacaine was administered if the patient requested additional analgesia, and the lockout time was set at 30 min. Postoperative pain quality was assessed using a visual analog scale (VAS), and the incidence of patients requiring additional analgesics, motor blockade using a modified Bromage scale (MBS), and consumed doses of local anesthetic were assessed. Results. The VAS and incidence of rescue analgesics were performed when the patient could communicate voluntarily after admission to the post-anesthetic care unit, and at 24 and 48 h after surgery showed no significant difference between the two groups. The MBS at 24 h after surgery was significantly higher in group B ( = 0.038). In the comparison of consumed doses of local anesthetic, group B had a significantly higher bolus injection dose ( = 0.047) and frequency of bolus use in the 24 h after surgery ( = 0.034). Conclusion. The PIB method in CIBPB after arthroscopic shoulder surgery provided a similar analgesic effect, with a higher bolus injection dose of local anesthetic and increased motor blockade than the continuous infusion method.

2 January 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
HKHee Young Kim
Hee Young Kim
HKHye-Jin Kim
Hye-Jin Kim
JJJieun Jung
Jieun Jung
SHSeo-Ho Hong
Seo-Ho Hong
JYJi-Uk Yoon
Ji-Uk Yoon
Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach. An endotracheal tube (ETT) with a thermometer on the cuff allows for the measurement of tracheal temperature, providing a suitable alternative to core temperature measurement. This study aimed to assess the clinical reliability and accuracy of the thermometer in the ETT in comparison to the core temperature measured using a PAC. Methods: Eleven patients who underwent coronary artery bypass graft (CABG) surgery were enrolled in this study. The patients were intubated using an ETT equipped with a thermometer on the cuff, and a PAC was inserted. Temperature measurements of both the trachea and pulmonary artery blood were recorded at 5-minute intervals for 1 hour before starting cardiopulmonary bypass. The agreement between the two temperature measurement methods was investigated using the Bland-Altman plot with multiple measurements per subject, and the correlation was evaluated using the concordance correlation coefficient (CCC). Results: Eleven patients with a total of 143 pairs of data were included for analysis. The mean difference between the tracheal and pulmonary artery temperatures was −0.10°C. The 95% limit of agreement (LoA), calculated as ± 1.96 standard deviation, ranged from −0.35°C to 0.15°C. The 95% confidence interval for the lower and upper LoA was −0.51°C to −0.27°C and 0.07°C to 0.31°C, respectively. The maximum allowed difference (Δ) was set at 0.5°C. The majority of temperature differences fell within the LoA and were well below the maximum allowed difference. The CCC was 0.95, which indicates a substantial strength of agreement. Conclusions: The agreement between the tracheal and pulmonary artery temperature measurements using the ETT thermometer and pulmonary artery catheter, respectively, was found to be clinically reliable and accurate. Therefore, the tracheal temperature measurement can effectively represent the core temperature of the patients. Employing an ETT equipped with a thermometer on the cuff can serve as a reliable and independent method for measuring core temperature. Trial registration: Clinical trial registration number: NCT05595616.