Michael Firbank

Dr. Michael Firbank

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1997 in Applied Optics
Verified
Journal Article
Closed access
PDF file
EOEiji Okada
Eiji Okada
MFMichael Firbank
Michael Firbank
MSMartin Schweiger
Martin Schweiger
SASimon R. Arridge
Simon R. Arridge
MCMark Cope
Mark Cope
DDDavid T. Delpy
David T. Delpy
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

1 December 1993 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MHM Hiraoka
M Hiraoka
MFMichael Firbank
Michael Firbank
MEM Essenpreis
M Essenpreis
MCM Cope
M Cope
SAS R Arridge
S R Arridge
DDD T Delpy
D T Delpy
In order to quantify near-infrared spectroscopic (NIRS) data on an inhomogeneous medium, knowledge of the contribution of the various parts of the medium to the total NIRS signal is required. This is particularly true in the monitoring of cerebral oxygenation by NIRS, where the contribution of the overlying tissues must be known. The concept of the time point spread function (TPSF), which is used extensively in NIRS to determine the effective optical pathlength, is expanded to the more general inhomogeneous case. This is achieved through the introduction of the partial differential pathlength, which is the effective optical pathlength in the inhomogeneous medium, and an analytical proof of the applicability of the modified Beer-Lambert law in an inhomogeneous medium is shown. To demonstrate the use of partial differential pathlength, a Monte Carlo simulation of a two-concentric-sphere medium representing a simplified structure of the head is presented, and the possible contribution of the overlying medium to the total NIRS signal is discussed.

1 June 2004 in Archives of Neurology
Verified
Journal Article
Open access
PDF file
JOJohn O'Brien
John O'Brien
SCSean Colloby
Sean Colloby
JFJohn Fenwick
John Fenwick
EWE. David Williams
E. David Williams
MFMichael Firbank
Michael Firbank
IMIan G. McKeith
Ian G. McKeith
Dementia with Lewy bodies (DLB) is a common cause of dementia in late life, accounting for 10% to 20% of cases.1,2 While definitive diagnosis requires autopsy, accurate recognition during life is important as persons with DLB are hypersensitive to antipsychotic medication3,4 and respond well to cholinesterase inhibitors.5 Consensus clinical criteria6 have high (80%-90%) specificity, but sensitivity can be low, below 30% in some studies,7,8 with Alzheimer disease (AD) being the most common misdiagnosis.8,9 There is, therefore, a need to improve the accuracy of antemortem diagnosis, most particularly the separation of DLB from AD.

1 April 1993 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MFMichael Firbank
Michael Firbank
MHM Hiraoka
M Hiraoka
MEM Essenpreis
M Essenpreis
DDD T Delpy
D T Delpy
The optical properties of samples of bone from pig skull have been measured over the wavelength range 650-950 nm. The scattering phase function was measured on thin samples of the bone using a goniometer, and a value for the mean cosine g, of the scattering angle, was calculated. The scattering and absorption coefficients, mu s and mu a were then determined from measurements of diffuse reflectance and transmittance made with a pair of integrating spheres, by a step-wise search through a table of diffuse reflectance and transmittance versus mu a and mu s generated by a Monte Carlo model incorporating the measured scattering phase function. Values for g measured on six samples varied from 0.925 +/- 0.014 at 650 nm to 0.945 +/- 0.013 at 950 nm. Corresponding values for mu a and mu s measured on 18 samples were mu a = 0.04 +/- 0.002 mm-1, mu s = 35 +/- 0.7 mm-1 at 650 nm to mu a = 0.05 +/- 0.002 mm-1, mu s = 24 +/- 0.6 mm-1 at 950 nm.

1 June 1998 in Pediatric Research
Verified
Journal Article
Open access
PDF file
JMJudith H Meek
Judith H Meek
MFMichael Firbank
Michael Firbank
CEClare E Elwell
Clare E Elwell
JAJanette Atkinson
Janette Atkinson
OBOliver Braddick
Oliver Braddick
JWJohn S Wyatt
John S Wyatt
This study presents the first measurements using near infrared spectroscopy of changes in regional hemodynamics as a response to a visual stimulus in awake infants. Ten infants aged 3 d to 14 wk viewed a checkerboard with a 5-Hz pattern reversal. The emitter and detector (optodes) of a near infrared spectrophotometer were placed over the occipital region of the head. Changes in concentration of oxy- and deoxyhemoglobin (Hbo2 and Hb) were measured and compared during 10-s epochs of stimulus on and off. A control group of 10 infants aged 18 d to 13 wk were examined with the same setup, but with the optodes over the frontoparietal region. In the test group the total hemoglobin concentration (Hbo2 + Hb) increased while the stimulus was on by a mean (±SD) of 2.51 (±1.48) μmol·L-1. Nine out of 10 infants showed an Hbo2 increase, and 9 out of 10 an Hb increase related to the stimulus. There was no significant change in any of these parameters in the control group. The results imply that there is increased cerebral blood flow due to stimulation that is specific to the visual cortex and that infants, unlike adults, show increased cerebral oxygen utilization during activation that outstrips this hemodynamic effect. The study demonstrates that near infrared spectroscopy can be used as a practical and noninvasive method of measuring visual functional activation and its hemodynamic correlates in the awake infant.

22 November 1999 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MFMichael Firbank
Michael Firbank
ACA Coulthard
A Coulthard
RHR M Harrison
R M Harrison
EWE D Williams
E D Williams
The signal to noise ratio (SNR) is one of the important measures of the performance of a magnetic resonance imaging (MRI) system. The object of this study was to compare a single acquisition method, which estimates the noise from background pixels, with a dual acquisition method which estimates the noise from the subtraction of two sequentially acquired images. The dual acquisition method is more exact, but is slower to perform and requires image manipulation. A comparison between the two methods gave a good correlation, and a regression equation of SNRsingle = 1.1 + 0.94 SNRdual. The single acquisition method is therefore appropriate for use in a quality assurance programme, since it is quicker and simpler to perform and is a good indicator of the more exact measure.