Cardiac constructs fabricated using human induced pluripotent stem cells-derived cardiomyocytes (iPSCs-CMs) are useful for evaluating the cardiotoxicity of and cardiac response to new drugs. Previously, we fabricated scaffold-free three-dimensional (3D) tubular cardiac constructs using a bio-3D printer, which can load cardiac spheroids onto a needle array. In this study, we developed a method to measure the contractile force and to evaluate the drug response in cardiac constructs. Specifically, we measured the movement of the needle tip upon contraction of the cardiac constructs on the needle array. The contractile force and beating rate of the cardiac constructs were evaluated by analysing changes in the movement of the needle tip. To evaluate the drug response, contractile properties were measured following treatment with isoproterenol, propranolol, or blebbistatin, in which the movement of the needle tip was increased following isoproterenol treatment, but was decreased following propranolol or blebbistain, treatments. To evaluate cardiotoxicity, contraction and cell viability of the cardiac constructs were measured following doxorubicin treatment. Cell viability was found to decrease with decreasing movement of the needle tip following doxorubicin treatment. Collectively, our results show that this method can aid in evaluating the contractile force of cardiac constructs.
The safety and therapeutic efficacy of new drugs are tested in experimental animals. However, besides being a laborious, costly process, differences in drug responses between humans and other animals and potential cardiac adverse effects lead to the discontinued development of new drugs. Thus, alternative approaches to animal tests are needed. Cardiotoxicity and responses of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) to drugs are conventionally evaluated by cell seeding and two-dimensional (2D) culture, which allows measurements of field potential duration and the action potentials of CMs using multielectrode arrays. However, 2D-cultured hiPSC-CMs lack 3D spatial adhesion, and have fewer intercellular and extracellular matrix interactions, as well as different contractile behavior from CMs in vivo . This issue has been addressed using tissue engineering to fabricate three-dimensional (3D) cardiac constructs from hiPSC-CMs cultured in vitro . Tissue engineering can be categorized as scaffold-based and scaffold-free. In scaffold-based tissue engineering, collagen and fibrin gel scaffolds comprise a 3D culture environment in which seeded cells exhibit cardiac-specific functions and drug responses, whereas 3D cardiac constructs fabricated by tissue engineering without a scaffold have high cell density and form intercellular interactions. This review summarizes the characteristics of scaffold-based and scaffold-free cardiac tissue engineering and discusses the applications of fabricated cardiac constructs to drug screening.
Induced pluripotent stem cells (iPSCs) have become a prevalent topic after their discovery, advertised as an ethical alternative to embryonic stem cells (ESCs). Due to their ability to differentiate into several kinds of cells, including cardiomyocytes, researchers quickly realized the potential for differentiated cardiomyocytes to be used in the treatment of heart failure, a research area with few alternatives. This paper discusses the differentiation process for human iPSC-derived cardiomyocytes and the possible applications of said cells while answering some questions regarding ethical issues.
The fabrication of mature engineered cardiac tissue is one of the major challenges in cardiac tissue engineering. For this purpose, we attempted to apply the 3D bioprinting approach. Aiming to construct an oriented tissue, a fine fiber-shaped scaffold with a support structure was first designed using CAD software. Then, a 3D bioprinter and cell-adhesive bio-inks were utilized to fabricate this structure. The cell-adhesive bio-inks were synthesized by combining sodium alginate and gelatin with tyramine, respectively, to form pre-gel materials that allow enzymatic crosslinking by horseradish peroxidase. By absorbance measurements, we confirmed that the tyramine modification rate of each polymer was 0.535 mmol/g-alginate and 0.219 mmol/g-gelatin. The width of the fiber-shaped scaffold was 216.8 ± 24.3 μm for the fabricated scaffold, while the design value was 200 μm. After 3D printing and adhesion-adding treatment of the scaffold with these bio-ink materials, cardiomyocytes were seeded and cultured. As a result, the cells spread onto the scaffold, and the entire pre-tissue contracted synchronously by day 6 of culture, showing a greater pulsatility than in the early days. Video analysis showed that the beating rate of pre-myocardial tissue on day 6 was 31 beats/min. In addition, we confirmed that the cardiomyocytes partially elongated along the long axis of the fiber-shaped scaffold in the pre-tissue cultured for 15 days by staining actin, suggesting the possibility of cell orientation. Furthermore, treatment with adrenaline resulted in a 7.7-fold increase in peak beating rate compared to that before treatment (from 6 beats/min to 46 beats/min), confirming the responsiveness of the pre-tissues to the drug. These results indicate that 3D bioprinting effectively produces mature cultured myocardial tissue that is oriented, contracts synchronously, and is responsive to drugs.
Biomaterial templates play a critical role in establishing and bioinstructing three-dimensional cellular growth, proliferation and spatial morphogenetic processes that culminate in the development of physiologically relevant in vitro liver models. Various natural and synthetic polymeric biomaterials are currently available to construct biomimetic cell culture environments to investigate hepatic cell–matrix interactions, drug response assessment, toxicity, and disease mechanisms. One specific class of natural biomaterials consists of the decellularized liver extracellular matrix (dECM) derived from xenogeneic or allogeneic sources, which is rich in bioconstituents essential for the ultrastructural stability, function, repair, and regeneration of tissues/organs. Considering the significance of the key design blueprints of organ-specific acellular substrates for physiologically active graft reconstruction, herein we showcased the latest updates in the field of liver decellularization–recellularization technologies. Overall, this review highlights the potential of acellular matrix as a promising biomaterial in light of recent advances in the preparation of liver-specific whole organ scaffolds. The review concludes with a discussion of the challenges and future prospects of liver-specific decellularized materials in the direction of translational research.
Introduction: Wound healing is severely compromised in patients with diabetes owing to factors such poor blood circulation, delayed immune response, elevated blood sugar levels, and neuropathy. Although the development of new wound healing products and prevention of serious complications such as infections in wounds have received substantial interest, wound healing remains a challenge in regenerative medicine. Burn wounds, especially third-degree burns, are difficult to treat because they are associated with immune and inflammatory reactions and distributive shock. Wound care and treatment that protects the burn site from infection and allows wound healing can be achieved with bioengineered wound dressings. However, few studies have reported effective dressings for third-degree burn wounds, making it important to develop new dressing materials. Methods: In this study, we developed an artificial amniotic membrane (AM) using epithelial and mesenchymal cells derived from human amnion as a novel dressing material. The artificial AM was applied to the wound of a diabetic third-degree burn model and its wound healing ability was evaluated. Results: This artificial amnion produced multiple growth factors associated with angiogenesis, fibroblast proliferation, and anti-inflammation. In addition, angiogenesis and granulation tissue formation were promoted in the artificial AM-treated mouse group compared with the control group. Furthermore, the inflammatory phase was prolonged in the control group. Conclusions: Our preliminary results indicate that the artificial AM might be useful as a new dressing for refractory ulcers and third-degree burns. This artificial AM-based material represents great potential for downstream clinical research and treatment of diabetes patients with third-degree burns. (c) 2024, The Japanese Society for Regenerative Medicine. Production and hosting by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).