Ming Chen

Dr. Ming Chen


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Cancer Letters
Verified
Journal Article
Closed access
YZYang Zhou
Yang Zhou
JXJiang Xu
Jiang Xu
HLHaichang Luo
Haichang Luo
XMXiangjing Meng
Xiangjing Meng
MCMing Chen
Ming Chen
DZDi Zhu
Di Zhu

17 September 2011 in Cell Biochemistry and Biophysics
Verified
Journal Article
Closed access
PDF file
JYJiyuan Yang
Jiyuan Yang
HLHesheng Luo
Hesheng Luo
YLYan Li
Yan Li
JLJunchuan Li
Junchuan Li
ZCZhiqiang Cai
Zhiqiang Cai
MCMing Chen
Ming Chen

1 December 2014 in International Journal of Nanomedicine
Verified
Journal Article
Open access
MCMing Chen
Ming Chen
XCXianglin Cheng
Xianglin Cheng
PXPu Xu
Pu Xu
JPJun Pen
Jun Pen
XZXiaobo Zhu
Xiaobo Zhu
DZDi Zhu
Di Zhu
Background: Rapid immunochromatographic tests can detect disease markers in 10–15 minutes, which facilitates clinical diagnosis and treatment programs. However, most immunochromatographic tests employ gold nanoparticles as reporters, and these have only moderate sensitivity and act as qualitative methods for analyzing high biomarker concentrations. Methods: In this study, we introduce quantum dots (QDs) as fluorescent probes and immunochromatographic strips to develop quantitative fluorescence point-of-care tests (QF-POCT) to analyze C-reactive protein (CRP) levels. Goat anti-rabbit IgG and rabbit IgG were used as control antibodies, and mouse monoclonal CRP antibody pairs were used for disease marker detection. One monoclonal CRP antibody was conjugated with QDs and served as a signal antibody, and the other monoclonal CRP antibody was dispensed onto the nitrocellulose membrane and served as a capturing antibody. In the presence of CRP, the fluorescence intensity of the monoclonal antibody-CRP-monoclonal antibody sandwich complex captured on the nitrocellulose membrane was determined using the fluorescence strip reader. Results: QF-POCT assays could quantitatively analyze the concentration of CRP in 15 minutes had a detection limit of 0.25 mg/L, and had a wide detection linearity range (0.5–300 mg/L). The intra-assay and interassay coefficients of variation were 8.95% and 9.86% at 0.5 mg/L, 6.47% and 8.66% at 10 mg/L, and 6.81% and 9.10% at 60 mg/L, respectively. In a comparison between clinical samples, the results of this QD-based assay of CRP levels were significantly correlated with those of an Immulite 2000 assay (R=0.993, P<0.001). Conclusion: Our results demonstrated that the QD-based immunochromatographic test is a rapid, sensitive, accurate, and quantitative method for the detection of disease biomarkers.

12 May 2025 in RSC Advances
Verified
Journal Article
Open access
PDF file
HDHong Ding
Hong Ding
YNYao Nie
Yao Nie
ZCZhen Chen
Zhen Chen
WZWanchao Zuo
Wanchao Zuo
JCJuan Cao
Juan Cao
MCMing Chen
Ming Chen
The PdNP-based LFIA for the detection of Lp-PLA2 address the sensitivity limitations of colorimetric LFIA, due to the excellent visual discriminability and target recognition ability.

30 August 2024 in Endocrine Practice
Verified
Journal Article
Closed access
LLLi Li
Li Li
XDXiaoxia Ding
Xiaoxia Ding
XZXihui Zhang
Xihui Zhang
SKShuangming Kong
Shuangming Kong
MCMing Chen
Ming Chen