Ge Wang

Prof. Ge Wang

Biomedical Imaging Center, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
hu chenhu chen
hu chen
YZYi Zhang
Yi Zhang
MKMannudeep K. Kalra
Mannudeep K. Kalra
FLFeng Lin
Feng Lin
YCYang Chen
Yang Chen
Ge WangGe Wang
Ge Wang
Given the potential risk of X-ray radiation to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. Currently, the main stream low-dose CT methods include vendor-specific sinogram domain filtration and iterative reconstruction algorithms, but they need to access raw data, whose formats are not transparent to most users. Due to the difficulty of modeling the statistical characteristics in the image domain, the existing methods for directly processing reconstructed images cannot eliminate image noise very well while keeping structural details. Inspired by the idea of deep learning, here we combine the autoencoder, deconvolution network, and shortcut connections into the residual encoder-decoder convolutional neural network (RED-CNN) for low-dose CT imaging. After patch-based training, the proposed RED-CNN achieves a competitive performance relative to the-state-of-art methods in both simulated and clinical cases. Especially, our method has been favorably evaluated in terms of noise suppression, structural preservation, and lesion detection.

17 April 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
QYQingsong Yang
Qingsong Yang
PYPingkun Yan
Pingkun Yan
YZYanbo Zhang
Yanbo Zhang
HYHengyong Yu
Hengyong Yu
YSYongyi Shi
Yongyi Shi
Ge WangGe Wang
Ge Wang
The continuous development and extensive use of computed tomography (CT) in medical practice has raised a public concern over the associated radiation dose to the patient. Reducing the radiation dose may lead to increased noise and artifacts, which can adversely affect the radiologists' judgment and confidence. Hence, advanced image reconstruction from low-dose CT data is needed to improve the diagnostic performance, which is a challenging problem due to its ill-posed nature. Over the past years, various low-dose CT methods have produced impressive results. However, most of the algorithms developed for this application, including the recently popularized deep learning techniques, aim for minimizing the mean-squared error (MSE) between a denoised CT image and the ground truth under generic penalties. Although the peak signal-to-noise ratio is improved, MSE- or weighted-MSE-based methods can compromise the visibility of important structural details after aggressive denoising. This paper introduces a new CT image denoising method based on the generative adversarial network (GAN) with Wasserstein distance and perceptual similarity. The Wasserstein distance is a key concept of the optimal transport theory and promises to improve the performance of GAN. The perceptual loss suppresses noise by comparing the perceptual features of a denoised output against those of the ground truth in an established feature space, while the GAN focuses more on migrating the data noise distribution from strong to weak statistically. Therefore, our proposed method transfers our knowledge of visual perception to the image denoising task and is capable of not only reducing the image noise level but also trying to keep the critical information at the same time. Promising results have been obtained in our experiments with clinical CT images.

9 January 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
HCHu Chen
Hu Chen
YZYi Zhang
Yi Zhang
WZWeihua Zhang
Weihua Zhang
PLPeixi Liao
Peixi Liao
KLKe Li
Ke Li
Ge WangGe Wang
Ge Wang
In order to reduce the potential radiation risk, low-dose CT has attracted an increasing attention. However, simply lowering the radiation dose will significantly degrade the image quality. In this paper, we propose a new noise reduction method for low-dose CT via deep learning without accessing original projection data. A deep convolutional neural network is here used to map low-dose CT images towards its corresponding normal-dose counterparts in a patch-by-patch fashion. Qualitative results demonstrate a great potential of the proposed method on artifact reduction and structure preservation. In terms of the quantitative metrics, the proposed method has showed a substantial improvement on PSNR, RMSE and SSIM than the competing state-of-art methods. Furthermore, the speed of our method is one order of magnitude faster than the iterative reconstruction and patch-based image denoising methods.

20 April 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
QXQiong Xu
Qiong Xu
HYHengyong Yu
Hengyong Yu
XMXuanqin Mou
Xuanqin Mou
LZLei Zhang
Lei Zhang
JHJiang Hsieh
Jiang Hsieh
Ge WangGe Wang
Ge Wang
Although diagnostic medical imaging provides enormous benefits in the early detection and accuracy diagnosis of various diseases, there are growing concerns on the potential side effect of radiation induced genetic, cancerous and other diseases. How to reduce radiation dose while maintaining the diagnostic performance is a major challenge in the computed tomography (CT) field. Inspired by the compressive sensing theory, the sparse constraint in terms of total variation (TV) minimization has already led to promising results for low-dose CT reconstruction. Compared to the discrete gradient transform used in the TV method, dictionary learning is proven to be an effective way for sparse representation. On the other hand, it is important to consider the statistical property of projection data in the low-dose CT case. Recently, we have developed a dictionary learning based approach for low-dose X-ray CT. In this paper, we present this method in detail and evaluate it in experiments. In our method, the sparse constraint in terms of a redundant dictionary is incorporated into an objective function in a statistical iterative reconstruction framework. The dictionary can be either predetermined before an image reconstruction task or adaptively defined during the reconstruction process. An alternating minimization scheme is developed to minimize the objective function. Our approach is evaluated with low-dose X-ray projections collected in animal and human CT studies, and the improvement associated with dictionary learning is quantified relative to filtered backprojection and TV-based reconstructions. The results show that the proposed approach might produce better images with lower noise and more detailed structural features in our selected cases. However, there is no proof that this is true for all kinds of structures.

10 December 2020 in Nature Machine Intelligence
Verified
Journal Article
Closed access
PDF file
Ge WangGe Wang
Ge Wang
JYJong Chul Ye
Jong Chul Ye
BMBruno De Man
Bruno De Man

17 March 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
FFFENGLEI FAN
FENGLEI FAN
JXJinjun Xiong
Jinjun Xiong
MLMengzhou Li
Mengzhou Li
Ge WangGe Wang
Ge Wang
Deep learning as performed by artificial deep neural networks (DNNs) has achieved great successes recently in many important areas that deal with text, images, videos, graphs, and so on. However, the black-box nature of DNNs has become one of the primary obstacles for their wide adoption in mission-critical applications such as medical diagnosis and therapy. Because of the huge potentials of deep learning, the interpretability of DNNs has recently attracted much research attention. In this article, we propose a simple but comprehensive taxonomy for interpretability, systematically review recent studies on interpretability of neural networks, describe applications of interpretability in medicine, and discuss future research directions, such as in relation to fuzzy logic and brain science.