17 April 2018 in IEEE Transactions on Medical Imaging
The continuous development and extensive use of computed tomography (CT) in medical practice has raised a public concern over the associated radiation dose to the patient. Reducing the radiation dose may lead to increased noise and artifacts, which can adversely affect the radiologists' judgment and confidence. Hence, advanced image reconstruction from low-dose CT data is needed to improve the diagnostic performance, which is a challenging problem due to its ill-posed nature. Over the past years, various low-dose CT methods have produced impressive results. However, most of the algorithms developed for this application, including the recently popularized deep learning techniques, aim for minimizing the mean-squared error (MSE) between a denoised CT image and the ground truth under generic penalties. Although the peak signal-to-noise ratio is improved, MSE- or weighted-MSE-based methods can compromise the visibility of important structural details after aggressive denoising. This paper introduces a new CT image denoising method based on the generative adversarial network (GAN) with Wasserstein distance and perceptual similarity. The Wasserstein distance is a key concept of the optimal transport theory and promises to improve the performance of GAN. The perceptual loss suppresses noise by comparing the perceptual features of a denoised output against those of the ground truth in an established feature space, while the GAN focuses more on migrating the data noise distribution from strong to weak statistically. Therefore, our proposed method transfers our knowledge of visual perception to the image denoising task and is capable of not only reducing the image noise level but also trying to keep the critical information at the same time. Promising results have been obtained in our experiments with clinical CT images.
2 May 2018 in IEEE Transactions on Medical Imaging
Low-dose computed tomography (LDCT) has attracted major attention in the medical imaging field, since CT-associated X-ray radiation carries health risks for patients. The reduction of the CT radiation dose, however, compromises the signal-to-noise ratio, which affects image quality and diagnostic performance. Recently, deep-learning-based algorithms have achieved promising results in LDCT denoising, especially convolutional neural network (CNN) and generative adversarial network (GAN) architectures. This paper introduces a conveying path-based convolutional encoder-decoder (CPCE) network in 2-D and 3-D configurations within the GAN framework for LDCT denoising. A novel feature of this approach is that an initial 3-D CPCE denoising model can be directly obtained by extending a trained 2-D CNN, which is then fine-tuned to incorporate 3-D spatial information from adjacent slices. Based on the transfer learning from 2-D to 3-D, the 3-D network converges faster and achieves a better denoising performance when compared with a training from scratch. By comparing the CPCE network with recently published work based on the simulated Mayo data set and the real MGH data set, we demonstrate that the 3-D CPCE denoising model has a better performance in that it suppresses image noise and preserves subtle structures.
20 July 2018 in IEEE Access
Computed tomography (CT) is a popular medical imaging modality and enjoys wide clinical applications. At the same time, the X-ray radiation dose associated with CT scannings raises a public concern due to its potential risks to the patients. Over the past years, major efforts have been dedicated to the development of low-dose CT (LDCT) methods. However, the radiation dose reduction compromises the signal-to-noise ratio, leading to strong noise and artifacts that down-grade the CT image quality. In this paper, we propose a novel 3-D noise reduction method, called structurally sensitive multi-scale generative adversarial net, to improve the LDCT image quality. Specifically, we incorporate 3-D volumetric information to improve the image quality. Also, different loss functions for training denoising models are investigated. Experiments show that the proposed method can effectively preserve the structural and textural information in reference to the normal-dose CT images and significantly suppress noise and artifacts. Qualitative visual assessments by three experienced radiologists demonstrate that the proposed method retrieves more information and outperforms competing methods.
14 September 2016 in IEEE Transactions on Computational Imaging
Photon-counting detectors can acquire x-ray intensity data in different energy bins. The signal-to-noise ratio of resultant raw data in each energy bin is generally low due to the narrow bin width and quantum noise. To address this problem, here we propose an image reconstruction approach for spectral CT to simultaneously reconstruct x-ray attenuation coefficients in all the energy bins. Because the measured spectral data are highly correlated among the x-ray energy bins, the intraimage sparsity and interimage similarity are important prior knowledge for image reconstruction. Inspired by this observation, the total variation and spectral mean measures are combined to improve the quality of reconstructed images. For this purpose, a linear mapping function is used to minimalize image differences between energy bins. The split Bregman technique is applied to perform image reconstruction. Our numerical and experimental results show that the proposed algorithms outperform competing iterative algorithms in this context.