Aims: The aim of this study was to evaluate the accuracy and consistency of responses given by two different versions of Chat Generative Pre‐trained Transformer (ChatGPT), ChatGPT‐4, and ChatGPT‐4o, to multiple‐choice questions prepared from undergraduate endodontic education topics at different times of the day and on different days. Methodology: In total, 60 multiple‐choice, text‐based questions from 6 topics of undergraduate endodontic education were prepared. Each question was asked to ChatGPT‐4 and ChatGPT‐4o 3 times a day (morning, noon, and evening) and for 3 consecutive days. The accuracy and consistency of AIs were compared using SPSS and R programs ( p < .05, 95% confidence interval). Results: The accuracy rate of ChatGPT‐4o (92.8%) was significantly higher than that of ChatGPT‐4 (81.7%; p < .001). The question groups affected the accuracy rates of both AIs ( p < .001). The times at which the questions were asked did not affect the accuracy of either AI ( p > .05). There was no statistically significant difference in the consistency rate between ChatGPT‐4 and ChatGPT‐4o ( p = .123). The question groups did not affect the consistency of either AI, too ( p > .05). Conclusions: According to the results of this study, the accuracy of ChatGPT‐4o was better than that of ChatGPT‐4. These findings demonstrate that AI chatbots can be used in dental education. However, it is also necessary to consider the limitations and potential risks associated with AI.
Preventing coronal microleakage is crucial for long-term endodontic success; this ex vivo study compared the sealing performance of five intra-orifice barrier (IOB) material application protocols with that of a no-IOB control. Sixty maxillary anterior teeth were randomly assigned to six groups (n = 10): control, flowable composite, universal composite, resin-modified glass ionomer cement (RMGIC), high-viscosity bulk-fill composite, and flowable bulk-fill composite. Following endodontic treatment, 2 mm-thick barriers were placed in five groups. All specimens underwent 1000 thermocycles and 24 h immersion in 2% methylene blue. Linear dye penetration was measured at ×50 using stereomicroscopy and ImageJ. Data were analyzed using one-way ANOVA with Tukey’s HSD test (α = 0.05). Microleakage differed significantly among groups (F (5, 54) = 12.473; p < 0.001). The lowest mean microleakage was observed with the Estelite Sigma Quick (EQ) (1.85 ± 0.59 mm), followed by the Estelite Bulk Fill Flow (EF) (2.28 ± 0.91 mm) and Filtek One Bulk Fill Restorative (FR) (2.48 ± 1.18 mm). No statistically significant differences were detected among these materials; however, each demonstrated significantly less microleakage than the Tetric N-Flow (TNF), Ionoseal (IS), and no-IOB control (p < 0.05), among which no differences were detected (p > 0.05). Under the experimental conditions of this ex vivo study, the protocols involving the EQ and both bulk-fill resin composites (FR, EF) resulted in significantly lower coronal dye penetration than the protocols involving the TNF, IS and the no-IOB control.