Thomas Mittlmeier

Prof. Dr. Thomas Mittlmeier

orcid

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2001 in Spine
Verified
Journal Article
Closed access
FKFrank Kandziora
Frank Kandziora
RPRobert Pflugmacher
Robert Pflugmacher
MSMatti Scholz
Matti Scholz
KSKlaus Schnake
Klaus Schnake
MLMartin Lucke
Martin Lucke
TMThomas Mittlmeier
Thomas Mittlmeier
The quantitative anatomic, radiographic, computerized tomographic, and biomechanical data of sheep and human cervical spines were evaluated. To compare the anatomic, radiographic, computerized tomographic, and biomechanical data of human and sheep cervical spines to determine whether the sheep spine is a suitable model for human spine research. Sheep spines have been used in several in vivo and in vitro experiments. Quantitative data of the normal sheep cervical spine are lacking, yet these data are crucial to discussion about the results of such animal studies. In this study, 20 fresh adult female Merino sheep cervical spines and 20 fresh human cadaver cervical spines were evaluated anatomically, radiographically, computerized tomographically, and biomechanically. Three linear and two angular parameters were evaluated on four digital radiographic views: anteroposterior, right lateral in neutral position, flexion, and extension. Quantitative computed tomography scans at the center of each vertebral body and 3 mm below both endplates were analyzed for bone mineral density measurements. Biomechanical testing was performed in flexion, extension, axial rotation, and lateral bending by a nondestructive stiffness method using a nonconstrained testing apparatus. Range of motion and stiffness of each motion segment were calculated. Additionally, 10 linear anatomic parameters of each vertebra were measured using a digital ruler. Anterior and mean disc space height in the sheep cervical spine increased constantly from C2-C3 to C6-C7, whereas middle disc space height decreased and posterior disc space height remained unchanged. Anterior and mean disc space height were significantly higher in sheep. In both sheep and human cervical spines, intervertebral angles were not significantly different. Standard deviations of bone mineral density in the human cervical spine were fourfold higher than in the sheep cervical spine, yet no significant differences were found in bone mineral density values between the two species. Range of motion differed significantly between the two species except in flexion-extension of C3-C4, C5-C6, axial rotation of C2-C3, and lateral bending of C2-C3, C3-C4, and C4-C5. Stiffness also was significantly different except in flexion-extension of C2-C3, C4-C5, C5-C6, and lateral bending of C2-C3, C3-C4, and C4-C5. Anatomic evaluation showed no difference in upper endplate parameters for C4 and C5. Although several differences were found between human and sheep cervical spines, the small intergroup standard deviations and the good comparability with the human spine encourage the use of the sheep cervical spine as a model for cervical spine research. On the basis of the quantitative data obtained in this study, the sheep motion segment C3-C4 seemed to be the most reliable model for the corresponding human motion segment.

1 January 2003 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
TMThomas Mittlmeier
Thomas Mittlmeier
HSH.-W. Stedtfeld
H.-W. Stedtfeld
AEA. Ewert
A. Ewert
MBM. Beck
M. Beck
BFB. Frosch
B. Frosch
GGG. Gradl
G. Gradl

1 January 2006 in Gait & Posture
Verified
Journal Article
Closed access
AVAttila Vasarhelyi
Attila Vasarhelyi
TBTobias Baumert
Tobias Baumert
CFChristoph Fritsch
Christoph Fritsch
WHWerner Hopfenmüller
Werner Hopfenmüller
GGGeorg Gradl
Georg Gradl
TMThomas Mittlmeier
Thomas Mittlmeier

1 December 2004 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
HSHans-Werner Stedtfeld
Hans-Werner Stedtfeld
TMThomas Mittlmeier
Thomas Mittlmeier
PLPeter Landgraf
Peter Landgraf
AEAndreas Ewert
Andreas Ewert

1 November 2009 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
GGG. Gradl
G. Gradl
ADA. Dietze
A. Dietze
MKM. Kääb
M. Kääb
WHW. Hopfenmüller
W. Hopfenmüller
TMThomas Mittlmeier
Thomas Mittlmeier
The optimal surgical treatment of displaced proximal humeral fractures is controversial. New implants providing angular stability have been introduced to maintain the intraoperative reduction. In a multi-institutional study, we prospectively enrolled and followed 152 patients with unilateral displaced and unstable proximal humeral fractures treated either with an antegrade angular and sliding stable proximal interlocking nail or an angular stable plate. Fractures were classified according to the Neer four-segment classification. Clinical, functional, and radiographic followups were performed 3, 6, and 12 months after surgery. Absolute and relative (to the contralateral shoulder) Constant-Murley scores were used to assess postoperative shoulder function. Using age, gender, and fracture type, we identified 76 pairs (152 patients) for a matched-pairs analysis. Relative Constant-Murley scores 12 months after treatment with an angular and sliding stable nail and after plate fixation were 81% and 77%, respectively. We observed no differences between the two groups. Stabilization of displaced proximal humeral fractures with either an angular stable intramedullary or an extramedullary implant seems suitable with both surgical treatment options. Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

1 March 2010 in European Spine Journal
Verified
Journal Article
Open access
PDF file
RRRobert Rotter
Robert Rotter
HMHeiner Martin
Heiner Martin
SFSebastian Fuerderer
Sebastian Fuerderer
MGMichael Gabl
Michael Gabl
CRChristoph Roeder
Christoph Roeder
TMThomas Mittlmeier
Thomas Mittlmeier
Vertebroplasty and kyphoplasty are well-established minimally invasive treatment options for compression fractures of osteoporotic vertebral bodies. Possible procedural disadvantages, however, include incomplete fracture reduction or a significant loss of reduction after balloon tamp deflation, prior to cement injection. A new procedure called “vertebral body stenting” (VBS) was tested in vitro and compared to kyphoplasty. VBS uses a specially designed catheter-mounted stent which can be implanted and expanded inside the vertebral body. As much as 24 fresh frozen human cadaveric vertebral bodies (T11-L5) were utilized. After creating typical compression fractures, the vertebral bodies were reduced by kyphoplasty (n = 12) or by VBS (n = 12) and then stabilized with PMMA bone cement. Each step of the procedure was performed under fluoroscopic control and analysed quantitatively. Finally, static and dynamic biomechanical tests were performed. A complete initial reduction of the fractured vertebral body height was achieved by both systems. There was a significant loss of reduction after balloon deflation in kyphoplasty compared to VBS, and a significant total height gain by VBS (mean ± SD in %, p < 0.05, demonstrated by: anterior height loss after deflation in relation to preoperative height [kyphoplasty: 11.7 ± 6.2; VBS: 3.7 ± 3.8], and total anterior height gain [kyphoplasty: 8.0 ± 9.4; VBS: 13.3 ± 7.6]). Biomechanical tests showed no significant stiffness and failure load differences between systems. VBS is an innovative technique which allows for the possibly complete reduction of vertebral compression fractures and helps maintain the restored height by means of a stent. The height loss after balloon deflation is significantly decreased by using VBS compared to kyphoplasty, thus offering a new promising option for vertebral augmentation.