Obstructive sleep apnea is a globally prevalent concern with significant health impacts, especially when coupled with comorbidities. Accurate detection and localization of airway obstructions are crucial for effective diagnosis and treatment, which remains a challenge for traditional sleep monitoring methods. Here, we report a catheter-based flexible pressure sensor array that continuously monitors soft tissue pressure in the upper airway and facilitates at the millimeter level. The sensor’s design and versatile 3D femtosecond laser fabrication process enable adaptation to diverse materials and applications. In vitro testing demonstrates high sensitivity (38.1 Ω/mmHg) and excellent stability. The sensor array effectively monitors distributed airway pressure and accurately identifies obstructions in an obstructive sleep apnea animal model. In this work, we highlight the potential of this catheter-based sensor array for long-term, continuous upper airway pressure monitoring and its prospective applications in other medical devices for pressure measurement in human body cavities.
The confocal Raman microscope (CRM) is a powerful tool in analytical science. Image quality is the most important performance indicator of CRM systems. The point spread function (PSF) is one of the most useful tools to evaluate the image quality of microscopic systems. A method based on a point-like object is proposed to measure the PSF of CRM, and the size effect of spherical objects is discussed. A series of phantoms are fabricated by embedding different sizes of polystyrene microspheres into polydimethylsiloxane matrix. The diameters of microspheres are from 0.2 µm to 5 µm. The phantoms are tested by measuring the PSF of a commercial CRM whose nominal lateral resolution is about 1 µm. Results of the PSF are obtained and the accuracy of resolution is used to evaluate the size effect of the microspheres. Experimental results are well consistent with theoretical analysis. The error of the PSF can be decreased by reducing the diameter of the microsphere but meanwhile the signal-to-noise ratio (S/N) will be lowered as well. The proper diameter of microspheres is proposed in consideration of the trade-off between the S/N and the measurement error of the PSF. Results indicate that the method provides a useful approach to measurement of the PSF and the resolution of the CRM.
Auto-focusing technology in ultrafast laser processing, especially for non-planar structures, holds paramount importance. The existing methodologies predominantly rely on optical mechanisms, thereby being limited by the original system and material reflectivity. This work proposes an approach that utilizes laser-induced sound as a feedback signal for system control, thereby circumventing the need for optical system adjustments and facilitating almost real-time tracking. We established an ultrafast laser processing system augmented by acoustic emission technology, allowing for focus tracking on inclined planes. This system also exhibits the capability to generate diverse microscopic morphologies, including grooves and differently oriented laser-induced periodic surface structures (LIPSS), through the manipulation of the acoustic signal threshold. This method can be easily integrated into existing laser processing systems, offering new capabilities for curved surface processing, microstructure manufacturing, and transparent material processing.
Improving surface bioactivity is crucial to acquiring zirconia implants with ideal osteoconductivity. In this work, we enhanced the surface properties of zirconia implants, specifically roughness, hydrophilicity, and osteoconductivity, using a “one-step” femtosecond laser (FSL) treatment in air, deionized water, and sodium hydroxide solution. Zirconia specimens were treated in these media, and their surface morphology, chemical composition, and osteoconductivity were evaluated through various assays. The results showed that FSL treatment successfully created micro/nanoporous structures and increased roughness across all specimens. The liquid media treatment facilitated the grafting of hydroxyl (-OH) groups, significantly improving hydrophilicity. The L-NaOH group exhibited a higher hydroxyl content (28%) compared to the L-Air group (10%), reducing the contact angle significantly. Enhanced osteoblast differentiation and mineralization, along with improved gene expression, were observed in the L-Water and L-NaOH groups. In conclusion, the one-step FSL treatment developed a dual-function bioactive zirconia surface, offering an effective method for the biomedical functionalization of zirconia implants.
9 December 2025 in Journal of Materials Research and Technology