Tong Xiaxia

Mrs. Tong Xiaxia


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2025 in Vaccines
Verified
Journal Article
Open access
PDF file
LLLixin Li
Lixin Li
TXTong Xiaxia
Tong Xiaxia
SJShu JianHong
Shu JianHong
HFHuapeng Feng
Huapeng Feng
YQYanping Quan
Yanping Quan
YHYulong He
Yulong He
Background: Porcine reproductive and respiratory syndrome is caused by PRRSV. Modified live vaccines (MLVs) are widely used to control PRRSV infection, but their efficacy against the emerging NADC30-like variant remains unclear. This study aimed to evaluate the efficacy of a VR-2332-based MLV against the NADC30-like PRRSV strain HNjz15. Methods: Forty piglets were randomized into a vaccination group (MLV group), negative control group (NC group), and sentinel group. MLV group piglets were immunized with a commercial MLV at 3 weeks of age and challenged with HNjz15 (106.6 TCID50/mL) at 21 days post-immunization. Clinical symptoms, viral load, antibody responses, cytokine levels, and lung lesions were monitored for 14 days post-challenge. Results: Although fever and respiratory symptoms were more pronounced in the NC group pigs than those of the MLV group (average percent occurrence: 65.2% vs. 52.9%), there was no statistical difference (p > 0.05) in the occurrence of respiratory symptoms between the two groups from 5 dpc. Reduced weight gains (by 40–53%) were also observed in the MLV and NC groups compared with the sentinels. The MLV and NC groups exhibited severe lung lesions, while there was no marked difference in viral RNA loads in serum and tissue samples between the MLV and NC groups (p > 0.05). The MLV vaccine induced a significant high level of N protein-specific antibodies compared to the NC group. There was also no significant difference in IFN-γ or TNF-α response to the HNjz15 challenge in both groups (p > 0.05). Conclusions: The VR-2332-based MLV does not provide adequate protection against challenge with the PRRSV-2 NADC30-like strain HNjz15.

9 January 2025 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
STSirui Tao
Sirui Tao
YDYu Duan
Yu Duan
YZYinhe Zha
Yinhe Zha
TXTong Xiaxia
Tong Xiaxia
YHYulong He
Yulong He
SJShu JianHong
Shu JianHong
Porcine circovirus type 2 (PCV2) is the main and primary causative agent of Postweaning Multisystemic Wasting Syndrome (PMWS). To date, immunoperoxidase monolayer assay (IPMA), indirect immunofluorescent assay (IFA), and enzyme linked immunosorbent assay (ELISA) are the most commonly diagnostic methods for detecting PCV2 antigens. However, these methods require specialized equipment and technical expertise and are suitable for laboratory use only. This study aims to develop an immunochromatographic strip and a magnetic chemiluminescence immunoassay for the detection of PCV2 antigens. The recombinant protein was constructed using a prokaryotic expression system, and the polyclonal antibody was obtained by animal experiments. Polystyrene microspheres are used as solid phase carriers to covalently bind to the amino groups of proteins to form immunoprobes. Monodisperse beads are covalently bound to antigens or antibodies as solid phases to bind antibodies or antigens in the liquid phase in a superior manner, thereby capturing and separating antigens and antibodies in the liquid phase. The immunochromatographic strip is qualitative detection method, this method can detect PCV2a strain, PCV2b strain, and PCV2d strain. The immunochromatographic strip had minimum detection limits of 102.89TCID50/0.1 mL, 103.19TCID50/0.1 mL, and 103.49TCID50/0.1 mL for PCV2a/LG, PCV2b/SH, and PCV2d/JH. The results of testing PEDV (CV777 strain), PRV (HB2000 strain), CSFV (WH-09 strain), PRRS (JXA1-R strain), PPV (WH-1 strain), and ASFV (SD strain) were negative. The agreement between the immunochromatographic strip and the ELISA kit was 93.33% (140/150) and the Kappa was 0.866 (Kappa > 0.81). On the premise of ensuring sensitivity, the most important feature of the immunochromatographic strip is that this method can save time when testing; results can be obtained within 5 to 10 min. Magnetic chemiluminescence immunoassay is quantitative detection method; this method can detect PCV2 Cap proteins in swine serum, the linear range of this method was 0.25 ng/mL to 32 ng/mL and R2 of the standard curve was 0.9993. The limit of detection (LOD) is 0.051 ng/mL and the limit of quantitation (LOQ) is 0.068 ng/mL. The agreement between the magnetic chemiluminescence immunoassay and the ELISA kit (test PCV2 Cap proteins) was 97.14% (68/70). This method took less than 30 min to achieve results, which is less than the ELISA kit. The results of this study show that immunochromatographic strip and magnetic chemiluminescence immunoassay for PCV2 antigens had great sensitivity and specificity, which lays the foundation for PCV2 clinical detection.