Yu Hu

Yu Hu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2018 in Materials
Verified
Journal Article
Open access
PDF file
HZHe Zhu
He Zhu
QLQingbin Li
Qingbin Li
YHYu Hu
Yu Hu
RMRui Ma
Rui Ma
Early-age restrained creep influences the cracking properties of concrete. However, conventional creep measurements require a large number of tests to predict the restrained creep as it is influenced by the combined effects of variable temperature, creep recovery, and varying compression and tension stresses. In this work, a double feedback control method for temperature stress testing was developed to measure the early-age restrained creep of concrete. The results demonstrate that the conventional single feedback control method neglects the effect of restrained elastic deformation, thus providing a larger-than-actual creep measurement. The tests found that the double feedback control method eliminates the influence of restrained elastic deformation. The creep results from the double feedback method match well with results from the single feedback method after compensation for the effects of restrained elastic deformation is accounted for. The difference in restrained creep between the single and double feedback methods is significant for concrete with a low modulus of elasticity but can be neglected in concrete with a high modulus of elasticity. The ratio between creep and free deformation was found to be 40–60% for low, moderate, and high strength concretes alike. The double feedback control method is therefore recommended for determining the restrained creep using a temperature stress testing machine.

16 April 2017 in Materials
Verified
Journal Article
Open access
PDF file
HZHe Zhu
He Zhu
QLQingbin Li
Qingbin Li
YHYu Hu
Yu Hu
Cracking due to temperature and restraint in mass concrete is an important issue. A temperature stress testing machine (TSTM) is an effective test method to study the mechanism of temperature cracking. A synchronous closed loop federated control TSTM system has been developed by adopting the design concepts of a closed loop federated control, a detachable mold design, a direct measuring deformation method, and a temperature deformation compensation method. The results show that the self-developed system has the comprehensive ability of simulating different restraint degrees, multiple temperature and humidity modes, and closed-loop control of multi-TSTMs during one test period. Additionally, the direct measuring deformation method can obtain a more accurate deformation and restraint degree result with little local damage. The external temperature deformation affecting the concrete specimen can be eliminated by adopting the temperature deformation compensation method with different considerations of steel materials. The concrete quality of different TSTMs can be guaranteed by being vibrated on the vibrating stand synchronously. The detachable mold design and assembled method has greatly overcome the difficulty of eccentric force and deformation.

10 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
WLweijia Liu
weijia Liu
XNXu-Jing Niu
Xu-Jing Niu
NYNing Yang
Ning Yang
YTYao-Shen Tan
Yao-Shen Tan
YQYu Qiao
Yu Qiao
YHYu Hu
Yu Hu
Mass concrete is usually poured in layers. To ensure the interlayer bonding quality of concrete, the lower layer should be kept in a plastic state before the upper layer is added. Ultimately, it will lead to the prediction of concrete setting time as a critical task in concrete pouring. In this experiment, the setting time of concrete in laboratory and field environments was investigated. The equivalent age of concrete at the initial setting was also analyzed based on the maturity theory. Meanwhile, factors affecting the setting time in the field environment were studied by means of multiple stepwise regression analysis. Besides, the interlayer splitting tensile strength of concrete subjected to different temperatures and wind speeds was determined. The results of laboratory tests show that both setting time and interlayer splitting tensile strength of concrete decrease significantly with the increase of air temperature and wind speed. In addition, the equivalent age of concrete at initial setting remains the same when subjected to different temperatures, while it decreases obviously with the increase of wind speed. In the field environment, the equivalent age of concrete at initial setting is greatly different, which is related to the variability of relative humidity and wind speed. The average air temperature and maximum wind speed are the main factors affecting the initial setting time of concrete. Furthermore, a prediction model is established based on the stepwise regression analysis results, which can predict the actual setting state in real-time, and hence controlling the interlayer bonding quality of dam concrete.

1 January 2014 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
QLQingbin Li
Qingbin Li
GLGuohe Liang
Guohe Liang
YHYu Hu
Yu Hu
ZZZheng Zuo
Zheng Zuo
The thermal boundary conditions in the construction and operation phases of a concrete arch dam are always complex. After sealing, differences between the arch dam temperature and its sealing temperature can cause compressive or tensile stresses. Based on measured temperature of an arch dam located in China, a temperature rise phenomenon (TRP) is found in the after‐sealed regions of the arch dam. By mining and analyzing the temperature data of various monitoring apparatus embedded in the arch dam, higher environment temperature is considered to be the main cause for the occurrence of the TRP. Mathematical methods for complex thermal boundary conditions, including external boundary conditions and internal heat source conditions, are proposed in this paper. A finite element model is implemented with the concern of the construction phase and operation phase of the arch dam. Results confirm good agreement with the measured temperature and verify the conjecture that the TRP occurs mainly because the external temperature of the arch dam is higher than its sealing temperature.

1 March 2017 in Journal of Aerospace Engineering
Verified
Journal Article
Closed access
QLQingbin Li
Qingbin Li
ZZZheng Zuo
Zheng Zuo
YHYu Hu
Yu Hu
GLGuohe Liang
Guohe Liang
The structural behavior during the first reservoir-filling phase is significant for evaluating a super high arch dam’s safety. This paper presents an in situ monitoring network of the Xiluodu Dam in Yunnan, China, including a deformation monitoring system using geodetic and nongeodetic monitoring. The system also includes a refined thermal monitoring system based on a slab-level active cooling system. The thermal–structural decoupling numerical analysis method for a dam–water–foundation system is presented in this study with considerations of viscoelasticity material properties and internal/external thermal loads. The structural behavior of the Xiluodu Dam during the first reservoir-filling phase is analyzed using the smart monitoring system with combination of the in situ monitoring technique and the numerical simulation method. The in situ monitoring result can provide intuitional instructions of the structural behavior, showing a positive correlation between the dam deformation and the reservoi...

3 February 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Xiaofeng GAOXiaofeng GAO
Xiaofeng GAO
QLQingbin Li
Qingbin Li
ZLZhihong Liu
Zhihong Liu
JZJiangnan Zheng
Jiangnan Zheng
KWKai Wei
Kai Wei
YHYu Hu
Yu Hu
Due to the complex structure and stress distribution of dam galleries, cracks often appear during the construction, operation and maintenance periods of dams. This paper proposes a method to determine the real strength and fracture parameters of gallery concrete, considering environmental temperature and humidity. The strength and fracture tests were carried out for gallery concrete at various ages and under different curing temperature and humidity conditions. The influence of curing conditions on the mechanical properties of gallery concrete was quantitatively analyzed. The prediction equations of the strength and fracture parameters of gallery concrete under arbitrary temperature and humidity were established. Based on the measured temperature and humidity data, the real mechanical parameters of gallery concrete were predicted. The research results show that the influence of environmental conditions on mechanical parameters cannot be neglected, as this can result in a strength reduction of up to 33.81%. The proposed equations can be used to predict the mechanical parameters of gallery concrete, subject to real environmental conditions, which can help to correct a maximum deviation of 54.62% on parameters calculated using actual ages. The proposed method can provide a scientific basis for the cracking risk analysis and safety assessment of the gallery structure under actual conditions.