Shigeho Tanaka

Prof. Shigeho Tanaka

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
CTCatrine Tudor-Locke
Catrine Tudor-Locke
CCCora L Craig
Cora L Craig
MBMichael W Beets
Michael W Beets
SBSarahjane Belton
Sarahjane Belton
GCGreet Cardon
Greet Cardon
SBSteven N Blair
Steven N Blair
Worldwide, public health physical activity guidelines include special emphasis on populations of children (typically 6-11 years) and adolescents (typically 12-19 years). Existing guidelines are commonly expressed in terms of frequency, time, and intensity of behaviour. However, the simple step output from both accelerometers and pedometers is gaining increased credibility in research and practice as a reasonable approximation of daily ambulatory physical activity volume. Therefore, the purpose of this article is to review existing child and adolescent objectively monitored step-defined physical activity literature to provide researchers, practitioners, and lay people who use accelerometers and pedometers with evidence-based translations of these public health guidelines in terms of steps/day. In terms of normative data (i.e., expected values), the updated international literature indicates that we can expect 1) among children, boys to average 12,000 to 16,000 steps/day and girls to average 10,000 to 13,000 steps/day; and, 2) adolescents to steadily decrease steps/day until approximately 8,000-9,000 steps/day are observed in 18-year olds. Controlled studies of cadence show that continuous MVPA walking produces 3,300-3,500 steps in 30 minutes or 6,600-7,000 steps in 60 minutes in 10-15 year olds. Limited evidence suggests that a total daily physical activity volume of 10,000-14,000 steps/day is associated with 60-100 minutes of MVPA in preschool children (approximately 4-6 years of age). Across studies, 60 minutes of MVPA in primary/elementary school children appears to be achieved, on average, within a total volume of 13,000 to 15,000 steps/day in boys and 11,000 to 12,000 steps/day in girls. For adolescents (both boys and girls), 10,000 to 11,700 may be associated with 60 minutes of MVPA. Translations of time- and intensity-based guidelines may be higher than existing normative data (e.g., in adolescents) and therefore will be more difficult to achieve (but not impossible nor contraindicated). Recommendations are preliminary and further research is needed to confirm and extend values for measured cadences, associated speeds, and MET values in young people; continue to accumulate normative data (expected values) for both steps/day and MVPA across ages and populations; and, conduct longitudinal and intervention studies in children and adolescents required to inform the shape of step-defined physical activity dose-response curves associated with various health parameters.

Yosuke YamadaYosuke Yamada
Yosuke Yamada
MNMiyuki Nishizawa
Miyuki Nishizawa
TUTomoka Uchiyama
Tomoka Uchiyama
YKYasuhiro Kasahara
Yasuhiro Kasahara
MSMikio Shindo
Mikio Shindo
STShigeho Tanaka
Shigeho Tanaka
Background: Appendicular skeletal muscle (or lean) mass (ALM) estimated using dual-energy X-ray absorptiometry (DXA) is considered to be a preferred method for sarcopenia studies. However, DXA is expensive, has limited portability, and requires radiation exposure. Bioelectrical impedance analysis (BIA) is inexpensive, easy to use, and portable; thus BIA might be useful in sarcopenia investigations. However, a large variety of models have been commercially supplied by different companies, and for most consumer products, the equations estimating ALM are not disclosed. It is therefore difficult to use these equations for research purposes. In particular, the BIA equation is often age-dependent, which leads to fundamental difficulty in examining age-related ALM loss. The aims of the current study were as follows: (1) to develop and validate an equation to estimate ALM using multi-frequency BIA (MF-BIA) based on theoretical models, and (2) to establish sarcopenia cutoff values using the equation for the Japanese population. Methods: We measured height (Ht), weight, and ALM obtained using DXA and a standing-posture 8-electrode MF-BIA (5, 50, 250 kHz) in 756 Japanese individuals aged 18 to 86-years-old (222 men and 301 women as developing equation group and 97 men and 136 women as a cross validation group). The traditional impedance index (Ht2/Z50) and impedance ratio of high and low frequency (Z250/Z5) of hand to foot values were calculated. Multiple regression analyses were conducted with ALM as dependent variable in men and women separately. Results: We created the following equations: ALM = (0.6947 × (Ht2/Z50)) + (−55.24 × (Z250/Z5)) + (−10,940 × (1/Z50)) + 51.33 for men, and ALM = (0.6144 × (Ht2/Z50)) + (−36.61 × (Z250/Z5)) + (−9332 × (1/Z50)) + 37.91 for women. Additionally, we conducted measurements in 1624 men and 1368 women aged 18 to 40 years to establish sarcopenia cutoff values in the Japanese population. The mean values minus 2 standard deviations of the skeletal muscle mass index (ALM/Ht2) in these participants were 6.8 and 5.7 kg/m2 in men and women, respectively. Conclusion: The current study established and validated a theoretical and age-independent equation using MF-BIA to estimate ALM and provided reasonable sarcopenia cutoff values.

7 February 2007 in European Journal of Clinical Nutrition
Verified
Journal Article
Closed access
AGA A Ganpule
A A Ganpule
STShigeho Tanaka
Shigeho Tanaka
KIK Ishikawa-Takata
K Ishikawa-Takata
ITI Tabata
I Tabata

1 October 2003 in Acta Diabetologica
Verified
Journal Article
Closed access
PDF file
STShigeho Tanaka
Shigeho Tanaka
CHC. Horimai
C. Horimai
FKF. Katsukawa
F. Katsukawa

2 August 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
HMHaruka Murakami
Haruka Murakami
RKRyoko Kawakami
Ryoko Kawakami
SNSatoshi Nakae
Satoshi Nakae
Yosuke YamadaYosuke Yamada
Yosuke Yamada
Yoshio NakataYoshio Nakata
Yoshio Nakata
MMMotohiko Miyachi
Motohiko Miyachi
Background: Self-monitoring using certain types of pedometers and accelerometers has been reported to be effective for promoting and maintaining physical activity (PA). However, the validity of estimating the level of PA or PA energy expenditure (PAEE) for general consumers using wearable devices has not been sufficiently established. Objective: We examined the validity of 12 wearable devices for determining PAEE during 1 standardized day in a metabolic chamber and 15 free-living days using the doubly labeled water (DLW) method. Methods: A total of 19 healthy adults aged 21 to 50 years (9 men and 10 women) participated in this study. They followed a standardized PA protocol in a metabolic chamber for an entire day while simultaneously wearing 12 wearable devices: 5 devices on the waist, 5 on the wrist, and 2 placed in the pocket. In addition, they spent their daily lives wearing 12 wearable devices under free-living conditions while being subjected to the DLW method for 15 days. The PAEE criterion was calculated by subtracting the basal metabolic rate measured by the metabolic chamber and 0.1×total energy expenditure (TEE) from TEE. The TEE was obtained by the metabolic chamber and DLW methods. The PAEE values of wearable devices were also extracted or calculated from each mobile phone app or website. The Dunnett test and Pearson and Spearman correlation coefficients were used to examine the variables estimated by wearable devices. Results: On the standardized day, the PAEE estimated using the metabolic chamber (PAEEcha) was 528.8±149.4 kcal/day. The PAEEs of all devices except the TANITA AM-160 (513.8±135.0 kcal/day; P>.05), SUZUKEN Lifecorder EX (519.3±89.3 kcal/day; P>.05), and Panasonic Actimarker (545.9±141.7 kcal/day; P>.05) were significantly different from the PAEEcha. None of the devices was correlated with PAEEcha according to both Pearson (r=−.13 to .37) and Spearman (ρ=−.25 to .46) correlation tests. During the 15 free-living days, the PAEE estimated by DLW (PAEEdlw) was 728.0±162.7 kcal/day. PAEE values of all devices except the Omron Active style Pro (716.2±159.0 kcal/day; P>.05) and Omron CaloriScan (707.5±172.7 kcal/day; P>.05) were significantly underestimated. Only 2 devices, the Omron Active style Pro (r=.46; P=.045) and Panasonic Actimarker (r=.48; P=.04), had significant positive correlations with PAEEdlw according to Pearson tests. In addition, 3 devices, the TANITA AM-160 (ρ=.50; P=.03), Omron CaloriScan (ρ=.48; P=.04), and Omron Active style Pro (ρ=.48; P=.04), could be ranked in PAEEdlw. Conclusions: Most wearable devices do not provide comparable PAEE estimates when using gold standard methods during 1 standardized day or 15 free-living days. Continuous development and evaluations of these wearable devices are needed for better estimations of PAEE.

30 May 2020 in Pediatrics International
Verified
Journal Article
Closed access
PDF file
CTChiaki Tanaka
Chiaki Tanaka
MTMark S. Tremblay
Mark S. Tremblay
MOMasayuki Okuda
Masayuki Okuda
STShigeho Tanaka
Shigeho Tanaka