Quan Chen

Dr. Quan Chen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2024 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JDJingwei Duan
Jingwei Duan
RTRiley C. Tegtmeier
Riley C. Tegtmeier
CVCarlos E. Vargas
Carlos E. Vargas
NYNathan Y. Yu
Nathan Y. Yu
BLBrady S. Laughlin
Brady S. Laughlin
YRYi Rong
Yi Rong

31 July 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
LLLuo Luo
Luo Luo
Hamed HooshangnejadHamed Hooshangnejad
Hamed Hooshangnejad
XFXue Feng
Xue Feng
GHGaofeng Huang
Gaofeng Huang
XCXiaojian Chen
Xiaojian Chen
Kai DingKai Ding
Kai Ding
Background: Lung cancer ranks as the leading cause of cancer-related mortality worldwide. The complexity of tumor delineation, crucial for radiation therapy, requires expertise often unavailable in resource-limited settings. Artificial Intelligence (AI), particularly with advancements in deep learning (DL) and natural language processing (NLP), offers potential solutions yet is challenged by high false positive rates. Purpose: The Oncology Contouring Copilot (OCC) system is developed to leverage oncologist expertise for precise tumor contouring using textual descriptions, aiming to increase the efficiency of oncological workflows by combining the strengths of AI with human oversight. Methods: Our OCC system initially identifies nodule candidates from CT scans. Employing Language Vision Models (LVMs) like GPT-4V, OCC then effectively reduces false positives with clinical descriptive texts, merging textual and visual data to automate tumor delineation, designed to elevate the quality of oncology care by incorporating knowledge from experienced domain experts. Results: The deployment of the OCC system resulted in a 35.0% reduction in the false discovery rate, a 72.4% decrease in false positives per scan, and an F1-score of 0.652 across our dataset for unbiased evaluation. Conclusions: OCC represents a significant advance in oncology care, particularly through the use of the latest LVMs, improving contouring results by (1) streamlining oncology treatment workflows by optimizing tumor delineation and reducing manual processes; (2) offering a scalable and intuitive framework to reduce false positives in radiotherapy planning using LVMs; (3) introducing novel medical language vision prompt techniques to minimize LVM hallucinations with ablation study; and (4) conducting a comparative analysis of LVMs, highlighting their potential in addressing medical language vision challenges.

10 June 2025 in Cancers
Verified
Journal Article
Open access
PDF file
LZLibing Zhu
Libing Zhu
JRJean-Claude M. Rwigema
Jean-Claude M. Rwigema
XFXue Feng
Xue Feng
BABilaal Ansari
Bilaal Ansari
JDJingwei Duan
Jingwei Duan
QCQuan Chen
Quan Chen
Background/Objectives: The accurate delineation of primary tumors (GTVp) and metastatic lymph nodes (GTVn) in head and neck (HN) cancers is essential for effective radiation treatment planning, yet remains a challenging and laborious task. This study aims to develop a deep-learning-based auto-segmentation (DLAS) model trained on external datasets with false-positive elimination using clinical diagnosis reports. Methods: The DLAS model was trained on a multi-institutional public dataset with 882 cases. Forty-four institutional cases were randomly selected as the external testing dataset. DLAS-generated GTVp and GTVn were validated against clinical diagnosis reports to identify false-positive and false-negative segmentation errors using two large language models: ChatGPT-4 and Llama-3. False-positive ruling out was conducted by matching the centroids of AI-generated contours with the slice locations or anatomical regions described in the reports. Performance was evaluated using the Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95), and tumor detection precision. Results: ChatGPT-4 outperformed Llama-3 in accurately extracting tumor locations from the diagnostic reports. False-positive contours were identified in 15 out of 44 cases. The DSCmean of the DLAS contours for GTVp and GTVn increased from 0.68 to 0.75 and from 0.69 to 0.75, respectively, after the ruling-out process. Notably, the average HD95 value for GTVn decreased from 18.81 mm to 5.2 mm. Post ruling out, the model achieved 100% precision for GTVp and GTVn when compared with the results of physician-determined contours. Conclusions: The false-positive ruling-out approach based on diagnostic reports effectively enhances the precision of DLAS in the HN region. The model accurately identifies the tumor location and detects all false-negative errors.

25 November 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
YGYike Guo
Yike Guo
LLLuo Luo
Luo Luo
Hamed HooshangnejadHamed Hooshangnejad
Hamed Hooshangnejad
RZRui Zhang
Rui Zhang
XFXue Feng
Xue Feng
Kai DingKai Ding
Kai Ding
With the rapid development of artificial intelligence (AI), various deep learning (DL) methods have been introduced into radiation oncology. Among them, the generation of synthetic Computed Tomography (sCT) images has attracted increasing attention, as it supports different clinical scenarios, from image-guided adaptive radiotherapy (IGART) to the simulation-free workflow. This review provides a comprehensive overview of recent studies on DL-based sCT synthesis in radiotherapy from multiple imaging modalities, including Cone-Beam CT (CBCT), Magnetic Resonance Imaging (MRI), and diagnostic CT, and discusses their clinical applications in CBCT-based online adaptive radiotherapy, MRI-guided radiotherapy, and simulation-free workflows. We also examine the architectures of representative DL models such as convolutional neural networks (CNNs) and generative adversarial networks (GANs) and summarize emerging training strategies. Finally, we discuss current challenges of clinical translation of DL algorithms into clinical practice and suggest potential directions for future research. Overall, this paper highlights the potential of AI-driven sCT generation to advance treatment planning by reducing imaging burden, improving dose accuracy, and accelerating workflow efficiency, thus ultimately improving the treatment outcome of patient care.

23 September 2025 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
QCQuan Chen
Quan Chen

12 June 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
LZLibing Zhu
Libing Zhu
NYNathan Y. Yu
Nathan Y. Yu
SASafia K. Ahmed
Safia K. Ahmed
JAJonathan B. Ashman
Jonathan B. Ashman
DTDiego Santos Toesca
Diego Santos Toesca
YRYi Rong
Yi Rong
Purpose: Lattice radiation therapy (LRT) is a form of spatially fractionated radiation therapy that allows increased total dose delivery aiming for improved treatment response without an increase in toxicities, commonly utilized for palliation of bulky tumors. The LRT treatment planning process is complex, while eligible patients often have an urgent need for expedited treatment start. In this study, we aimed to develop a simulation‐free workflow for volumetric modulated arc therapy (VMAT)‐based LRT planning via deep learning‐predicted synthetic CT (sCT) to expedite treatment initiation. Methods: Two deep learning models were initially trained using 3D U‐Net architecture to generate sCT from diagnostic CTs (dCT) of the thoracic and abdomen regions using a training dataset of 50 patients. The models were then tested on an independent dataset of 15 patients using image similarity analysis assessing mean absolute error (MAE) and structural similarity index measure (SSIM) as metrics. VMAT‐based LRT plans were generated based on sCT and recalculated on the planning CT (pCT) for dosimetric accuracy comparison. Differences in dose volume histogram (DVH) metrics between pCT and sCT plans were assessed using the Wilcoxon signed‐rank test. Results: The final sCT prediction model demonstrated high image similarity to pCT, with a MAE and SSIM of 38.93 ± 14.79 Hounsfield Units (HU) and 0.92 ± 0.05 for the thoracic region, and 73.60 ± 22.90 HU and 0.90 ± 0.03 for the abdominal region, respectively. There were no statistically significant differences between sCT and pCT plans in terms of organ‐at‐risk and target volume DVH parameters, including maximum dose (Dmax), mean dose (Dmean), dose delivered to 90% (D90%) and 50% (D50%) of target volume, except for minimum dose (Dmin) and (D10%). Conclusion: With demonstrated high image similarity and adequate dose agreement between sCT and pCT, our study is a proof‐of‐concept for using deep learning predicted sCT for a simulation‐free treatment planning workflow for VMAT‐based LRT.