Yong-Cheol Yoon

Prof. Dr. Yong-Cheol Yoon

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 February 2017 in Injury
Verified
Journal Article
Closed access
JCJae-Woo Cho
Jae-Woo Cho
WKWilliam T. Kent
William T. Kent
YYYong-Cheol Yoon
Yong-Cheol Yoon
YKYoungwoo Kim
Youngwoo Kim
HKHyungon Kim
Hyungon Kim
JOJK Oh
JK Oh

27 September 2017 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
JKJoon-Woo Kim
Joon-Woo Kim
YYYong-Cheol Yoon
Yong-Cheol Yoon
Chang-Wug OhChang-Wug Oh
Chang-Wug Oh
SHSeung-Beom Han
Seung-Beom Han
JSJae-Ang Sim
Jae-Ang Sim
JOJK Oh
JK Oh

1 June 2014 in Injury
Verified
Journal Article
Closed access
YYYong-Cheol Yoon
Yong-Cheol Yoon
AJAshutosh Jha
Ashutosh Jha
Chang-Wug OhChang-Wug Oh
Chang-Wug Oh
SDSenthil Kumar Durai
Senthil Kumar Durai
YKYoung-Woo Kim
Young-Woo Kim
JOJK Oh
JK Oh

19 July 2022 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
YYYong-Cheol Yoon
Yong-Cheol Yoon
CKChul-Ho Kim
Chul-Ho Kim
YKYong Chan Kim
Yong Chan Kim
HSHyung Keun Song
Hyung Keun Song
Yoon YC, et al. Yonsei Med J. 2022 Aug;63(8):744-750. https://doi.org/10.3349/ymj.2022.63.8.744

27 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JLJung-Soo Lee
Jung-Soo Lee
KKKwang Gi Kim
Kwang Gi Kim
YYYong-Cheol Yoon
Yong-Cheol Yoon
The extra-articular distal humerus plate (EADHP) has been widely used for surgical treatment of distal humerus shaft fracture (DHSF). However, the surgical approach, fixation methods, and implant positions of the EADHP remain controversial owing to iatrogenic radial nerve injury and complaints such as skin irritation related to the plate. Anterior plating with a modified (upside-down application) proximal humerus locking plate (PHILOS) has been proposed as an alternative, However, research on its biomechanical performance remain insufficient and were mostly based on retrospective studies. This study quantitatively compared and evaluated the biomechanical performance between posterior plating with the EADHP and anterior plating with a modified PHILOS using finite element analysis (FEA). The FEA simulation results that both the EADHP and PHILOS had adequate biomechanical performance and stability under axial, bending, and varus force load conditions. The PHILOS has a fixed stability comparable to that of the EADHP, and fixation was achieved using only four locking screws within a fixed range of 30 mm just above the olecranon fossa. The results show that the PHILOS could be an option for the fixation of a DHSF when considering the dissection range and complaints (e.g. skin irritation) associated with the EADHP.