Douglas Tasker

Dr. Douglas Tasker

Los Alamos National Laboratory, Los Alamos, NM, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
EFElizabeth Francois
Elizabeth Francois
DTDouglas Tasker
Douglas Tasker
RBRosemary Burritt
Rosemary Burritt
PBPatrick Bowden
Patrick Bowden
Insensitive High Explosives (IHEs) increase safety in many types of uses. However, the safety comes at the cost of performance. Initiation of IHE requires large boosters and powerful detonators as well. Multipoint initiation is being utilized to exploit explosive wave interactions to create overdriven states, greatly facilitating the initiation of IHEs. This concept builds from recent explosive experiments where the minimum spot size for single-point initiation in PBX 9502 was determined. Below this threshold, PBX 9502 could not be initiated. This was then expanded to three initiation points, which were smaller than this threshold. Measurements of the velocity and pressure of the wave interactions were collected using Photon Doppler Velocimetry (PDV). Not only was initiation observed, but the resulting pressures at the double and triple points were found to be above the CJ state for PBX 9502. Based on these results, further tests were conducted to isolate and measure the longevity and pressure of this phenomenon using a series of cutback tests.

1 July 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
DTDouglas Tasker
Douglas Tasker
DSDaniel A. Skrabacz
Daniel A. Skrabacz
MCMaria C. Campbell
Maria C. Campbell
KSKyle D. Spielvogel
Kyle D. Spielvogel
AMAllen G. Morinec
Allen G. Morinec
VMVirginia W. Manner
Virginia W. Manner
There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ∼1000 K on microsecond timescales. Wenograd [Trans. Faraday Soc. 57, 1612 (1961)] loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
DTDouglas Tasker
Douglas Tasker
VWVon H. Whitley
Von H. Whitley
CJCarl E. Johnson
Carl E. Johnson
It has been shown that the temperature of explosively generated plasma (EGP) is of the order of 1 eV and plasma ejecta can be focused to achieve velocities as high as 25 km/s. Proof-of-principle tests were performed to determine if EGP could be used for explosive ordnance demolition and other applications. The goals were: to benignly disable ordnance containing relatively sensitive high performance explosives (PBX-9501); and to investigate the possibility of interrupting an ongoing detonation in a powerful high explosive (again PBX-9501) with EGP. Experiments were performed to establish the optimum sizes of plasma generators for the benign deactivation of high explosives, i.e., the destruction of the ordnance without initiating a detonation or comparable violent event. These experiments were followed by attempts to interrupt an ongoing detonation by the benign disruption of the unreacted explosive in its path. The results were encouraging. First, it was demonstrated that high explosives could be destroyed without the initiation of a detonation or high order reaction. Second, ongoing detonations were successfully interrupted with EGP. [LA-UR-15-25350]

3 July 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
DTDouglas Tasker
Douglas Tasker
PBPatrick Bowden
Patrick Bowden
EFElizabeth Francois
Elizabeth Francois
JGJohn Gibson
John Gibson
TNTeagan Nakamoto
Teagan Nakamoto
ZWZakary Wilde
Zakary Wilde
Detonators are fundamental to most explosive systems, yet the detonators themselves are rarely diagnosed to determine how well they function or why they fail. To remedy this, various electrical diagnostics were explored, including: Rogowski coils for high fidelity detection of changes in electrical current in explosive bridgewires and how they relate to detonator performance; and radio frequency (RF) antennas to detect any electromagnetic emissions associated with reaction and growth in the explosives. A new type of Rogowski coil is described and some interesting phenomena were detected with the radio frequency antenna.

1 January 2005 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
SSSteven F. Son
Steven F. Son
TFTimothy Foley
Timothy Foley
VSV. Eric Sanders
V. Eric Sanders
ANAlan Novak
Alan Novak
DTDouglas Tasker
Douglas Tasker
BABlaine W. Asay
Blaine W. Asay

1 June 2005
Verified
Conference Paper
Closed access
DTDouglas Tasker
Douglas Tasker
JGJames H. Goforth
James H. Goforth
DHDennis H. Herrera
Dennis H. Herrera
DTDavid T. Torres
David T. Torres
JKJames C. King
James C. King
HOHenn Oona
Henn Oona
Isentropic compression experiments (ICE) using a high explosive pulsed power (HEPP) system have been developed to obtain isentropic equation of state data for metals at megabar pressures [1][2]. The HEPP system comprises a magnetic flux compressor, an explosively-driven opening switch and a series of closing switches; fast rising current pulses are produced, with rise times of ~500 ns at current densities exceeding many MA/cm. These currents create continuous magnetic loading of the metals under study. The success of these experiments depends on the precise control of the current profile, and that in turn depends on the precise timing of the closing switches to within 50 ns at currents of the order 10 MA and voltages of ~150 kV. We first used Procyon closing switches [3] but found their timing to be unacceptably imprecise for ICE with a jitter of typically 600 ns. We suspected that the switch timing was sensitive to applied voltage; this was subsequently confirmed by experiment, as we will show. A simple shock model was developed to explain the voltage sensitivity of closure time, dt/dV, and from the model we designed a low jitter switch that uses the shock-induced electrical conduction of polyimide. The predicted dt/dV was exactly equal to the measured value, thus confirming the model. This new switch design proved successful and met the 50 ns criterion; it is now used routinely in HEPP-ICE experiments.