Lumbar disc herniation is one of the primary causes of lower back pain, and its incidence has significantly increased with the development of industrialization. To assist in rehabilitation therapy, this paper proposes a flexible exoskeleton for active lumbar rehabilitation based on a 4-SPU/SP biomimetic parallel mechanism. By analyzing the anatomical structure and movement mechanisms of the lumbar spine, a four degree of freedom parallel mechanism was designed to mimic the three-axis rotation of the lumbar spine around the coronal, sagittal, and vertical axes, as well as movement along the z-axis. Using a 3D motion capture system, data on the range of motion of the lumbar spine was obtained to guide the structural design of the exoskeleton. Using the vector chain method, the display equations for the drive joints of the mechanism were derived, and forward and inverse kinematic models were established and simulated to verify their accuracy. The dynamic characteristics of the biomimetic parallel mechanism were analyzed and simulated to provide a theoretical basis for the design of the exoskeleton control system. A prototype was fabricated and tested to evaluate its maximum range of motion and workspace. Experimental results showed that after wearing the exoskeleton, the lumbar spine’s range of motion could still reach over 83.5% of the state without the exoskeleton, and its workspace could meet the lumbar spine movement requirements for daily life, verifying the rationality and feasibility of the proposed 4-SPU/SP biomimetic parallel mechanism design.
This study presents a two-segment continuum robot with piecewise stiffness, designed to enhance the precision, adaptability, and safety of tracheal intubation procedures. The robot employs a continuum manipulator (CM) as its end-effector, featuring a proximal segment (PS) with an aluminum alloy interlocking joint, which provides high axial stiffness for stable insertion, and a distal segment (DS) with a micro-nano resin-based notched structure, offering increased flexibility and compliance to navigate complex anatomical structures such as the epiglottis and vocal cords, thereby reducing airway trauma. To describe the motion behavior of the robot, a piecewise variable curvature kinematic model is developed, capturing the deformation characteristics of each segment under actuation. Furthermore, a piecewise stiffness analysis is conducted to determine the axial and bending stiffness of each segment, ensuring an appropriate balance between stability and flexibility. To enhance control precision, an active tendon-driven decoupling control strategy is introduced, effectively minimizing the interaction forces between flexible segments and improving end-effector maneuverability. The results demonstrate that the proposed design significantly improves the adaptability of the tracheal intubation robot, ensuring controlled insertion while reducing the risk of excessive force on the airway walls. This study provides theoretical and technical insights into the mechanical design and control strategies of continuum robots, contributing to the safety and efficiency of tracheal intubation.