Jai-yeop Lee

Dr. Jai-yeop Lee

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
ATAndinet Tekile
Andinet Tekile
IKIlho Kim
Ilho Kim
JLJai-yeop Lee
Jai-yeop Lee
This study utilized multistage orifice microbubble generator to investigate dissolved oxygen (DO) formation characteristics and to increase its efficiency, by considering saturator pressure, water supply, and gas flow rates as the main operating factors. The effect of changing the parameters was described in terms of dissolution performance using volumetric mass transfer rate, which is very important element for aerator design and scale-up. Pressure values from 1 to 6 atm were taken for the analysis. To improve the oxygen transfer efficiency of the multistage orifice, the internal supply line was controlled to circulate the bubbles water up to 300% cycling. The volumetric mass transfer coefficient was limited below 0.01 per min for air; however, the value varied from 0.10 to 0.13 per min for oxygen at 4.5 L/min flow rate, showing increasing pattern with pressure. The transfer characteristic was doubled, with circulating ratio applied, because circulation could multiply the number of microbubbles. Examining the various operating conditions within the range set for the cost to generate 1 kg of DO, under gas injection velocity of 1.27 m/s, higher liquid pressurization showed lower cost per production in case of oxygen than air. Thus, natural water bottom area environment can be economically improved using oxygen microbubbles, considering the excessive dissolution.

29 April 2022 in Water
Verified
Journal Article
Open access
PDF file
JAJesmin Akter
Jesmin Akter
JLJai-yeop Lee
Jai-yeop Lee
WKWeonJae Kim
WeonJae Kim
IKIlho Kim
Ilho Kim
The objective of this study is to investigate the consequence of ozone dosage rate on the qualitative change in organic compounds and nitrogen in anaerobic digester effluent during the ozone process. Therefore, ozonation improves the biodegradability of recalcitrant organic compounds, quickly oxidizes the unsaturated bond, and forms radicals that continue to deteriorate other organic matter. In this study, ozonation was performed in a microbubble column reactor; the use of microbubble ozone improves the status of chemical oxygen demand (COD) and changes of organic nitrogen to inorganic compounds. The ozone injection rates were 1.0, 3.2, and 6.2 mg/L/min. The samples obtained during the ozone treatments were monitored for CODMn, CODCr, TOC, NO2−-N, NO3−-N, NH4+-N, T-N, and Org-N. The ozone dose increased 1.0 to 6.2 mg/L and it increased the degradation ratio 40% and the total organic carbon 20% during 20 min of reaction time. During the ozonation, the CODCr and CODMn values were increased per unit of ozone consumption. The ozone treatment showed organic nitrogen mineralization and degradation of organic compounds with the contribution of the microbubble ozone oxidation process and is a good option for removing non-biodegradable organic compounds. The original application of the microbubble ozone process, with the degradation of organic compounds from a domestic wastewater treatment plant, was investigated.

8 February 2021 in Environmental Engineering Research
Verified
Journal Article
Closed access
PDF file
IKIlho Kim
Ilho Kim
JLJai-yeop Lee
Jai-yeop Lee
This study analyzed residues of PPCPs in secondary treated sewage water, and their amount eliminated by ozonation processes. A microbubble nozzle and ejector were used to dissolve ozone. To consider a low concentration of PPCPs, a SPE method was performed on samples prior to the analysis. The concentration of dissolved ozone was 4.00 mg/L in the microbubble and 2.49 mg/L in the ejector. To examine elimination trends, the experiment was also performed at a low concentration of ozone, 1/10 of its original concentration. The maximum elimination rate on average was 93.0% in the ejector, higher than that in the microbubble (90.1%), but 16 PPCPs were found to show a relatively high elimination rate in the microbubble, higher than the ejector. Elimination trends with respect to time were distinguished based on inflection point, and 11 PPCPs were concentrated on the latter half of the microbubble after the inflection point at the low concentration of ozone, which was compared to other cases. In the source water, concentrations of 2 PPCPs were higher than the reference toxic concentration based on the QSAR model, but after treatment, only bezafibrate was over the value when the ejector with low ozone injection concentration was applied.

6 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
JAJesmin Akter
Jesmin Akter
JLJai-yeop Lee
Jai-yeop Lee
HHHyun-Ju Ha
Hyun-Ju Ha
IYIn Geol Yi
In Geol Yi
DHDa-Hye Hong
Da-Hye Hong
IKIlho Kim
Ilho Kim
This study aimed to investigate the effect of H2O2 addition, ozone feed rate, and UV addition on the change in the concentration of organics such as CODMn, CODCr, TOC, and PFCs in tertiary-treated effluent from a sewage treatment plant (STP) during the O3 and UV/H2O2 process. The degradation of organic pollutants from tertiary effluent is a significant challenge because biological treatment cannot degrade these recalcitrant pollutants. Therefore, the O3/UV/H2O2 process was an effective method for treating recalcitrant organics. Several batch tests were conducted to investigate the direct UV photolysis, UV/H2O2, and ozone-based advanced oxidation process to degrade CODMn, CODCr, TOC, and PFCs. The chemical oxygen demand (COD) and total organic carbon (TOC) with UV irradiation showed 95% and 50% removal efficiency percentages under optimal conditions (initial pH = 6.7, H2O2 dosage = 50 mg/L, ozone feed rate = 5.8 mg/L/min. Moreover, UV irradiation, with the addition of H2O2, and a sufficient dose of ozone, demonstrated the efficient removal of organic compounds by the indication of radical oxidation. (·OH) is the dominant mechanism. However, AOPs are not sufficient to fully treat the PFC compound; thus, additional procedures are required to degrade PFCs. In this study, the removal of organic recalcitrant contaminants and the change in added PFC concentration in tertiary-treated sewage were investigated by applying the ozone-based advanced oxidation process.

24 November 2017 in Water
Verified
Journal Article
Open access
PDF file
ATAndinet Tekile
Andinet Tekile
IKIlho Kim
Ilho Kim
JLJai-yeop Lee
Jai-yeop Lee
For effective ultrasonic algae removal, several studies have considered the ultrasound equipment linked factors, such as power and frequency. However, studies on the response of mixed algal cultures and associated water quality parameters to ultrasound are limited. In this lab-scale sonication, the removal of cyanobacteria at a pre-set frequency of 200 kHz on mixed algae suspensions collected from a eutrophic lake was investigated. The caution (17.5 µg/L) and outbreak (1450 µg/L) alert levels in terms of chlorophyll-a (Chl-a) concentrations of the initial samples were each sonicated for 10, 15, and 20 min, and then kept in an incubator. Fifteen minutes of sonication resulted in best removal efficiency of 0.94 and 0.77, at an ultrasonic dose of 30 kWh/m3 at the outbreak and caution level concentrations, respectively. Immediately after 15 min sonication, and after standing in the incubator for a day, chlorophyll-a removal efficiencies of 0.28 and 0.90 were achieved in the outbreak level, respectively, and the matching removal efficiencies for the caution level were 0.23 and 0.64. Even though the removal was substantial in both cases, the final 147 µg/L chlorophyll-a concentration of the outbreak, which is itself still in the outbreak level range, shows that ultrasonication is not effective to satisfactorily remove algae from a concentrated suspension. Total dissolved nitrogen and chemical oxygen demand were reduced, overall, due to sonication. However, total dissolved phosphorus of the concentrated level was increased during the treatment. Although sonication needs further replicated experimental testing in whole-lake systems, our results show that 200 kHz sonication was able to reduce chlorophyll-a concentrations in small-scale laboratory tests.

5 September 2022 in Nitrogen
Verified
Journal Article
Open access
PDF file
JAJesmin Akter
Jesmin Akter
JLJai-yeop Lee
Jai-yeop Lee
IKIlho Kim
Ilho Kim
In this study, a lab-scale fixed-film bio-media process was developed and operated to evaluate nitrogen removal from domestic sewage treatment plants. For nitrogen removal, the fixed-film bio-media process was applied in series with anaerobic, anoxic, and aerobic units in three separate reactors that were operated continuously at the same loading rates and hydraulic retention time. A biofilm separation bioreactor was developed for on-site domestic wastewater treatment and the bioreactor employed synthetic fiber modules so that the biomass could be completely attached to the media. In this paper, the performance of the fixed-film bio-media process with an average flow rate was evaluated before and after stabilization of the treatment system for nitrogen removal. The results show that the fixed-film bio-media process was successful for improved nitrogen removal from secondary and tertiary treated wastewater, with a 77% decrease in the total nitrogen discharge. Rapid nitrification could be achieved, and denitrification was performed in the anoxic filter with external carbon supplements during tertiary treated sewage wastewater. However, aeration was supplied after the stabilization process to achieve the nitrification and denitrification reaction for nitrogen removal. However, stable aeration supply could enhance nitrification at moderate temperature with benefits from complete retention of nitrifying bacteria within the system due to bio-media separation.