Urs Eisenmann

Dr. Urs Eisenmann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
MDMartin Dugas
Martin Dugas
MBMax Blumenstock
Max Blumenstock
TDTobias Dittrich
Tobias Dittrich
UEUrs Eisenmann
Urs Eisenmann
SFStephan Christoph Feder
Stephan Christoph Feder
MGMatthias Ganzinger
Matthias Ganzinger
Structured patient data play a key role in all types of clinical research. They are often collected in study databases for research purposes. In order to describe characteristics of a next-generation study database and assess the feasibility of its implementation a proof-of-concept study in a German university hospital was performed. Key characteristics identified include FAIR access to electronic case report forms (eCRF), regulatory compliant Electronic Data Capture (EDC), an EDC with electronic health record (EHR) integration, scalable EDC for medical documentation, patient generated data, and clinical decision support. In a local case study, we then successfully implemented a next-generation study database for 19 EDC systems (n = 2217 patients) that linked to i.s.h.med (Oracle Cerner) with the local EDC system called OpenEDC. Desiderata of next-generation study databases for patient data were identified from ongoing local clinical study projects in 11 clinical departments at Heidelberg University Hospital, Germany, a major tertiary referral hospital. We compiled and analyzed feature and functionality requests submitted to the OpenEDC team between May 2021 and July 2023. Next-generation study databases are technically and clinically feasible. Further research is needed to evaluate if our approach is feasible in a multi-center setting as well.

21 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMatthias Schaufelberger
Matthias Schaufelberger
RKReinald Kuehle
Reinald Kuehle
AWAndreas Wachter
Andreas Wachter
FWFrederic Weichel
Frederic Weichel
NHNiclas Hagen
Niclas Hagen
WNWerner Nahm
Werner Nahm
Background: Craniosynostosis is a condition caused by the premature fusion of skull sutures, leading to irregular growth patterns of the head. Three-dimensional photogrammetry is a radiation-free alternative to the diagnosis using computed tomography. While statistical shape models have been proposed to quantify head shape, no shape-model-based classification approach has been presented yet. Methods: We present a classification pipeline that enables an automated diagnosis of three types of craniosynostosis. The pipeline is based on a statistical shape model built from photogrammetric surface scans. We made the model and pathology-specific submodels publicly available, making it the first publicly available craniosynostosis-related head model, as well as the first focusing on infants younger than 1.5 years. To the best of our knowledge, we performed the largest classification study for craniosynostosis to date. Results: Our classification approach yields an accuracy of 97.8 %, comparable to other state-of-the-art methods using both computed tomography scans and stereophotogrammetry. Regarding the statistical shape model, we demonstrate that our model performs similar to other statistical shape models of the human head. Conclusion: We present a state-of-the-art shape-model-based classification approach for a radiation-free diagnosis of craniosynostosis. Our publicly available shape model enables the assessment of craniosynostosis on realistic and synthetic data.

1 October 2017 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MBMoritz Berger
Moritz Berger
INIgor Nova
Igor Nova
SKSebastian Kallus
Sebastian Kallus
OROliver Ristow
Oliver Ristow
CFChristian Freudlsperger
Christian Freudlsperger
RSRobin Seeberger
Robin Seeberger

1 November 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MBMoritz Berger
Moritz Berger
SKSebastian Kallus
Sebastian Kallus
INIgor Nova
Igor Nova
OROliver Ristow
Oliver Ristow
UEUrs Eisenmann
Urs Eisenmann
RSRobin Seeberger
Robin Seeberger

14 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RKReinald Kuehle
Reinald Kuehle
FRFriedemann G. Ringwald
Friedemann G. Ringwald
FBFrederic Bouffleur
Frederic Bouffleur
NHNiclas Hagen
Niclas Hagen
MSMatthias Schaufelberger
Matthias Schaufelberger
UEUrs Eisenmann
Urs Eisenmann
Positional cranial deformities are a common finding in toddlers, yet differentiation from craniosynostosis can be challenging. The aim of this study was to train convolutional neural networks (CNNs) to classify craniofacial deformities based on 2D images generated using photogrammetry as a radiation-free imaging technique. A total of 487 patients with photogrammetry scans were included in this retrospective cohort study: children with craniosynostosis (n = 227), positional deformities (n = 206), and healthy children (n = 54). Three two-dimensional images were extracted from each photogrammetry scan. The datasets were divided into training, validation, and test sets. During the training, fine-tuned ResNet-152s were utilized. The performance was quantified using tenfold cross-validation. For the detection of craniosynostosis, sensitivity was at 0.94 with a specificity of 0.85. Regarding the differentiation of the five existing classes (trigonocephaly, scaphocephaly, positional plagiocephaly left, positional plagiocephaly right, and healthy), sensitivity ranged from 0.45 (positional plagiocephaly left) to 0.95 (scaphocephaly) and specificity ranged from 0.87 (positional plagiocephaly right) to 0.97 (scaphocephaly). We present a CNN-based approach to classify craniofacial deformities on two-dimensional images with promising results. A larger dataset would be required to identify rarer forms of craniosynostosis as well. The chosen 2D approach enables future applications for digital cameras or smartphones.

19 May 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MSMatthias Schaufelberger
Matthias Schaufelberger
CKChristian Kaiser
Christian Kaiser
RKReinald Kühle
Reinald Kühle
AWAndreas Wachter
Andreas Wachter
FWFrederic Weichel
Frederic Weichel
WNWerner Nahm
Werner Nahm
Objective: Diagnosis of craniosynostosis using photogrammetric 3D surface scans is a promising radiation-free alternative to traditional computed tomography. We propose a 3D surface scan to 2D distance map conversion enabling the usage of the first convolutional neural networks (CNNs)-based classification of craniosynostosis. Benefits of using 2D images include preserving patient anonymity, enabling data augmentation during training, and a strong under-sampling of the 3D surface with good classification performance. Methods: The proposed distance maps sample 2D images from 3D surface scans using a coordinate transformation, ray casting, and distance extraction. We introduce a CNN-based classification pipeline and compare our classifier to alternative approaches on a dataset of 496 patients. We investigate into low-resolution sampling, data augmentation, and attribution mapping. Results: Resnet18 outperformed alternative classifiers on our dataset with an F1-score of 0.964 and an accuracy of 98.4%. Data augmentation on 2D distance maps increased performance for all classifiers. Under-sampling allowed 256-fold computation reduction during ray casting while retaining an F1-score of 0.92. Attribution maps showed high amplitudes on the frontal head. Conclusion: We demonstrated a versatile mapping approach to extract a 2D distance map from the 3D head geometry increasing classification performance, enabling data augmentation during training on 2D distance maps, and the usage of CNNs. We found that low-resolution images were sufficient for a good classification performance. Significance: Photogrammetric surface scans are a suitable craniosynostosis diagnosis tool for clinical practice. Domain transfer to computed tomography seems likely and can further contribute to reducing ionizing radiation exposure for infants.