Introduction Direct quantification of drug concentrations allows for medication adherence monitoring (MAM) and therapeutic drug monitoring (TDM). Multiple less invasive methods have been developed in recent years: dried blood spots (DBS), saliva, and hair analyses. Aim To provide an overview of emerging drug quantification methods for MAM and TDM, focusing on the clinical validation of methods in patients prescribed chronic drug therapies. Methods A scoping review was performed using a systematic search in three electronic databases covering the period 2000–2020. Screening and inclusion were performed by two independent reviewers in Rayyan. Data from the articles were aggregated in a REDCap database. The main outcome was clinical validity of methods based on study sample size, means of cross-validation, and method description. Outcomes were reported by matrix, therapeutic area and application (MAM and/or TDM). Results A total of 4590 studies were identified and 175 articles were finally included; 57 on DBS, 66 on saliva and 55 on hair analyses. Most reports were in the fields of neurological diseases (37%), infectious diseases (31%), and transplantation (14%). An overview of clinical validation was generated of all measured drugs. A total of 62 drugs assays were applied for MAM and 131 for TDM. Conclusion MAM and TDM are increasingly possible without traditional invasive blood sampling: the strengths and limitations of DBS, saliva, and hair differ, but all have potential for valid and more convenient drug monitoring. To strengthen the quality and comparability of future evidence, standardisation of the clinical validation of the methods is recommended.
Purpose: Smart medication adherence monitoring devices can provide objective and granular drug utilization data and help patients engaging with their treatment. In this proof-of-concept study, the acceptability and technical robustness of a novel smart pill bottle prototype (SPBP) were assessed in order to allow further optimization. Methods: The SPBP is an app-controlled automatic dispense system, capturing real-time data on a web-based platform, which sends text reminders and measures storage conditions. A heterogeneous group of ten volunteers was asked to dispense placebo capsules with the SPBP and to follow a predefined dosing schedule for a trial period of 2 weeks. Afterwards, a questionnaire was filled out during a short interview. Primary outcome was dispense adherence as measured by the bottle. Other study outcomes included system acceptability (System Usability Scale [SUS]), self-reported adherence (MARS) and technical robustness of the bottle’s mechanics (electronic pill dispenser) and sensors (bottle temperature). Results: The overall dispense adherence rate as measured by the SPBP was 88%. All participants completed the study and four participants had an adherence rate of 100% during the study. The dispense adherence rates corresponded well with participants’ self-reported adherence with an average MARS total score of 23.6 (out of 25). Participants judged the system easy to use, with a mean SUS score of 79.3 (range: 57.5– 97.5). The overall mean temperature difference between the bottle sensor and calibrated external sensor was − 0.82°C (range: − 1.37°C to − 0.21°C). Conclusion: The SPBP was well accepted and this study provides data for further optimization and follow-up studies. Smart adherence technologies such as these may change the way healthcare professionals, trialists and patients manage medication adherence.
Purpose: An electronic version of the Dosepak® (EDP) which records date and time of dosing events has been developed to monitor adherence to medication packaged in blisters. This study aimed to evaluate its usability and acceptance and to monitor dose-taking adherence for optimal implementation in future clinical trials and practice. Methods: Healthy volunteers aged over 18 years were asked to dispense placebo tablets twice daily from EDPs equipped with a re-usable electronic module for a total duration of four weeks. Afterwards, subjects were asked to complete an online questionnaire and partake in a short one-on-one interview. The usability of the EDP was assessed using the System Usability Scale (SUS), while dose-taking adherence was monitored by EDP records, pill counting, and self-report. The short interview explored user experiences in more detail. Results: Twenty subjects with median [IQR] age 41.5 [32– 49.8] years, 55% female, 45% healthcare professionals, and 20% chronic medication users completed the study and found the EDP easy to use, with a mean [SD] SUS score of 78.0 [11.2]. Median [IQR] dose-taking adherence was 89% [82– 95%] based on EDP records, 96.5% [89– 100%] based on pill counting, 92% [91– 96%] based on self-report, and the levels differed significantly (p < 0.05). Four themes emerged from the interviews: user preference, experience, patient burden, and ideas for improvement. Most participants preferred smaller sized blisters. They found the EDP simple to use and did not see any patient burden for its use in trials or clinical practice. Some reported forgetfulness and suggested reminders built into the blister or sent to their mobile phones. Adequate information or instruction should also be provided for older people and polypharmacy patients. Conclusion: EDP had good perceived usability, was well accepted, and differed significantly from other adherence measurement methods. This study provides input to further guide scale-up of the blister packages.
Liquid chromatography with tandem mass spectrometry (LC-MS/MS) is the golden standard for immunosuppressants analyses, where optimising throughput by parallel chromatography can reduce costs and turnaround time. We aimed to double our system throughput using a dual LC-MS/MS setup. Therefore, two independent UPLC systems were hyphenated to one triple quadrupole MS, with staggered injections from one autosampler on alternating columns. The method simultaneously measured the analytes tacrolimus, sirolimus, everolimus, and cyclosporin A in whole blood using isotope dilution, with a run time of 1.5 min. Using the dual LC-MS/MS system, net run-to-run time improved from 2.3 to 0.98 min per injection, where throughput increased from 26 to 61 injections per hour. For Performance Qualification, 1101 clinical samples were measured on the dual LC-MS/MS system in addition to the standard system, during a period of one month, and the results were compared using Passing Bablok regression and Bland Altman analysis. There was excellent agreement for all four analytes, with regression slopes of 0.98-1.02x and intercepts of -0.11-0.88 µg/L. Minor bias was demonstrated between the systems with mean differences from -0.93 to 1.43%. In conclusion, the throughput was doubled and idle MS time was reduced with good agreement to the standard system. Currently, the method is applied for clinical routine with frequent peak intensities of >180 injections per day.
Traditionally, tacrolimus is assessed in whole blood samples, but this is suboptimal from the perspective that erythrocyte-bound tacrolimus is not a good representative of the active fraction. In this work, a straightforward and rapid method was developed for determination of plasma tacrolimus in solid organ transplant recipients, using liquid chromatography tandem mass spectrometry (LC-MS/MS) with heated electrospray ionisation. Sample preparation was performed through protein precipitation of 200 µl plasma with 500 µl stable isotopically labelled tacrolimus I.S. in methanol, where 20 µl was injected on the LC-MS/MS system. Separation was done using a chromatographic gradient on a C18 column (50 × 2.1 mm, 2.6 µm). The method was linear in the concentration range 0.05-5.00 µg/L, with within-run and between-run precision in the range 2-6 % and a run time of 1.5 min. Furthermore, the method was validated for selectivity, sensitivity, carry-over, accuracy and precision, process efficiency, recovery, matrix effect, and stability following EMA and FDA guidelines. Clinical validation was performed in 2333 samples from 1325 solid organ transplant recipients using tacrolimus (liver n = 312, kidney n = 1714, and lung n = 307), which had median plasma tacrolimus trough concentrations of 0.10 µg/L, 0.15 µg/L and 0.23 µg/L, respectively. This method is suitable for measurement of tacrolimus in plasma and will facilitate ongoing observational and prospective studies on the relationship of plasma tacrolimus concentrations with clinical outcomes.