Jilin Fan

Dr. Jilin Fan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
JFJilin Fan
Jilin Fan
YLYingming Liu
Yingming Liu
QCQian Chen
Qian Chen
FQFei Qiu
Fei Qiu
HSHaochen Song
Haochen Song

23 November 2023 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
JFJilin Fan
Jilin Fan
WCWenhui Chen
Wenhui Chen
AYAizhong Yue
Aizhong Yue
QZQiong Zhang
Qiong Zhang
FZFeng Zhang
Feng Zhang

4 December 2021 in Geophysics
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
JFJilin Fan
Jilin Fan
FQFei Qiu
Fei Qiu
BXBing Xie
Bing Xie
XLXianghui Li
Xianghui Li
HZHui Zhang
Hui Zhang
The low porosity and permeability characteristics of tight oil reservoirs have brought challenges to monitoring oil saturation recently. Although carbon/oxygen logging is effective for oil saturation evaluation, the statistical fluctuations of the measured energy spectrum in tight reservoirs make it impossible to distinguish the different signals between oil and water. Thus, noise adjusted singular-value decomposition (NASVD) is applied to denoise the raw energy spectrum and evaluate the oil saturation quantitatively. The energy spectrum matrix, which is composed of the energy spectrum of the measurement point and its adjacent depth points, is decomposed and reconstructed to remove noninformative signals and improve the signal-to-noise ratio of the raw energy spectrum. The parameter K evaluates the smoothness of the logging curves, reflecting the influence of the number of energy spectra and singular values on NASVD. Meanwhile, the NASVD, Savitzky-Golay filtering, and depth averaging methods are compared for calculating the accuracy of C/O, Si/Ca, and oil saturation with the Monte Carlo method, indicating that the NASVD is better than the other two methods for eliminating the statistical fluctuations of the raw energy spectrum. A simulation example indicates that the NASVD can control the calculation errors of tight reservoir oil saturation to within 15%, which significantly improves the accuracy of the estimated oil saturation. An oil field example indicates that the oil saturation interpretation result for tight reservoirs is in good agreement with the oil saturation from open-hole log analysis, signifying that the NASVD energy spectrum denoising method can provide a quantitative estimate of oil saturation in tight oil reservoirs.

24 January 2022 in Geophysics
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
CQChen Qian
Chen Qian
JLJuntao Liu
Juntao Liu
QZQuanying Zhang
Quanying Zhang
LTLili Tian
Lili Tian
XLXianghui Li
Xianghui Li
As the critical parameter of hydraulic fracture evaluation, fracture density is significant for fracturing model optimization and production prediction. To compensate for the low response sensitivity of fracture density and the saturation of fracture evaluation in nonradioactive technology (NRT), we have developed a method based on modifying the neutron self-shielding effect to quantitatively calculate fracture density. The gamma counts of elements with content that did not change before and after fracturing are used to calculate the self-shielding correction factor. We establish the mathematical relationship between the corrected gamma counts of boron and fracture density to achieve a quantitative calculation of fracture density. Compared to NRT, the new method uses measured energy spectral information to eliminate the effect of neutron self-shielding on fracture density and improve calculation accuracy. Meanwhile, the scope or range of accurate fracture density estimation extends from the original 4% to more than 10%. Moreover, we further examine fracture response under different formations and borehole conditions using the Monte Carlo N-particle transport code. The salinity of formation water and borehole water has the most significant impact on fracture density calculation, shale content and porosity, lithology, and fluid type of formation; in contrast, borehole parameters are the least significant. Finally, in this paper, we illustrate the feasibility of the method through a continuous-depth numerical calculation.

13 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JFJilin Fan
Jilin Fan
QZQiong Zhang
Qiong Zhang
Elemental gamma spectroscopy logging while drilling is crucial for assessing element content in unconventional oil and gas reservoirs. Unlike wireline elemental spectroscopy logging, the high cross section and high-density characteristics of the drill collar can interfere with the detection of formation element content. Using numerical simulation, this paper develops a drill collar background signal removal method based on a dual detector gamma energy and time spectra combination. First, the gamma counts ratio in different time periods from the time spectra of the dual detector and the gamma energy spectra measured by the near detector are used to characterize the drill collar background. Then, the energy spectra measured by the far detector are integrated to reconstruct the pure formation gamma energy spectra. The reconstructed gamma energy spectra demonstrate that the deviation of low-content element yields can be controlled within 0.5%, indicating the accuracy of the drill collar background removal method based on dual spectra information. A numerical simulation case of elemental logging while drilling in unconventional reservoirs is constructed, and the drill collar background is removed using the time spectra and energy spectra information of the dual detector. The calculation of element and mineral contents shows that the maximum calculation errors can be controlled within 2% and 3.5%, respectively, with the calculation error for low cross section elements like Mg reduced to below 0.5%. In conclusion, the proposed drill collar signal removal method based on the time and energy domains effectively improves the accuracy of formation elemental content calculation under drilling conditions, providing theoretical guidance and technical support for elemental content evaluation and mineral analysis in unconventional oil and gas reservoirs.

9 January 2024 in Geophysics
Verified
Journal Article
Closed access
FZFeng Zhang
Feng Zhang
BXBing Xie
Bing Xie
QCQian Chen
Qian Chen
XZXiaoyang Zhang
Xiaoyang Zhang
YAYiMula ABuLaHai
YiMula ABuLaHai
JFJilin Fan
Jilin Fan
Fracture density is a critical fracture evaluation parameter for the optimization and production prediction of hydraulic fracturing models. Nonradioactive tracer (NRT) techniques have successfully used a quantitative fracture density method based on neutron-induced gamma rays from formation elements. Furthermore, fracture density can be calculated using the formation capture cross section before and after hydraulic fracturing based on pulsed neutron capture logging. However, the response sensitivity of the macroscopic scattering cross section to the fractures decreases when the fracture density is high due to the neutron self-shielding phenomenon. Therefore, an improved fracture density evaluation method is applied, which combines the macroscopic capture cross section and the neutron self-shielding correction factor. In the new method, the peak area of titanium from the captured gamma spectrum is used to obtain a neutron self-shielding correction factor to improve the sensitivity of fracture density determination. Furthermore, the response of capture cross-section variation to fracture density at various tagged proppant concentrations and formation backgrounds is investigated. The findings indicate that the tagged proppant concentration influences the detection limit of fracture density and the sensitivity of fracture density identification. The accurate calculation range of fracture density using the new method has been extended from 5% to 10% under the condition that the tagged proppant concentration is 0.2%. Meanwhile, whereas water salinity significantly impacts capture cross-section variation, the effects of porosity, lithology, and fluid type on capture cross-section variation are negligible. A simulated fracturing example demonstrates the method’s applicability in various measurement environments. The results show that fracture density and height are consistent with the model settings after correcting for water salinity, and the fracture density calculation error is less than 3%. Therefore, our evaluation method for fracture density corrected for the neutron self-shielding effect improves response sensitivity and fracture density calculation accuracy.