Flexible electronics have demonstrated various strategies to enhance the sensory ability for tactile perception and wearable physiological monitoring. Fibrous microstructures have attracted much interest because of their excellent mechanical properties and fabricability. Herein, a structurally robust fibrous mat was first fabricated by electrospinning, followed by a sequential process of functionalization utilizing ultrasonication treatment and in situ polymerization growth. Electrospun polyurethane (PU) microfibers were anchored with multi-walled carbon nanotubes (MWCNTs) to form conductive paths along each fiber by a scalable ultrasonic cavitation treatment in an MWCNT suspension. After, a layer of poly(3,4-ethylene dioxythiophene) (PEDOT) was grown on the surface of PU fibers decorated with MWCNTs to enhance the conductive conjunctions of MWCNTs. Due to the superior electromechanical behaviors and mechanical reinforcement of PEDOT, the PEDOT/MWCNT@PU mat-based device exhibits a wide working range (0–70 kPa), high sensitivity (1.6 kPa−1), and good mechanical robustness (over 18,000 cycles). The PEDOT/MWCNT@PU mat-based sensor also demonstrates a good linear response to different temperature variations because of the thermoelectricity of the PEDOT/MWCNT composite. This novel strategy for the fabrication of multifunctional fibrous mats provides a promising opportunity for future applications for high-performance wearable devices.
Evanescent wave (EW)-based optical biosensors have rapidly evolved into indispensable tools for real-time, non-invasive, and ultra-sensitive detection of biomolecular interactions. By enabling label-free analysis with unprecedented precision, they have significantly reshaped the landscape of clinical diagnostics and personalized medicine. In recent years, interdisciplinary innovations spanning materials science, nanotechnology, photonic integration, and microfluidics have propelled EW biosensors beyond their conventional roles, endowing them with capabilities that were once considered unattainable. This review aims to provide a comprehensive and up-to-date synthesis of recent advances in EW-based biosensing technologies, with a particular emphasis on their transformative applications in the medical field. Specifically, it seeks to critically evaluate the progress achieved across major biosensor platforms and to explore how these innovations are bridging the gap between fundamental research and clinical translation. The review systematically examines three representative EW biosensor platforms-surface plasmon resonance (SPR) sensors, silicon photonic sensors, and optical fiber sensors-highlighting their operating principles and recent breakthroughs. Innovations such as nanomaterial-enhanced sensitivity, chip-scale multiplexing, and portable point-of-care designs are pushing the boundaries of biosensing performance. Furthermore, emerging approaches, including seamless microfluidic integration and artificial intelligence-driven data interpretation, are recognized as essential for developing next-generation intelligent and autonomous biosensors. These advances collectively position EW biosensors to revolutionize precision diagnostics and enable real-time health monitoring, heralding a new era of biomedical science.
13 September 2023 in Measurement Science and Technology
This paper presents a broadband ultrasonic rangefinder, with merits of a small blind area and high accuracy, based on a multi-frequency piezoelectric micromachined ultrasonic transducer (MF-PMUT) array. The coupling bandwidth between six types of resonant cells with adjacent resonant frequencies was studied and optimized, and these cells were then integrated into an array to broaden the bandwidth of the device. The array device showed a wide −6 dB fractional bandwidth of 108% in silicon oil. A wide bandwidth can contribute to obtaining the maximum steady-state with less excitation and reducing its residual ring-down, resulting in a small blind area. Pulse-echo ranging experiments demonstrated that the blind area was effectively reduced to 5 mm due to the multi-frequency array. For short distance measurements (<250 mm), the error was well controlled within ±0.3 mm and the 3σ accuracy was 0.445 mm. Compared with earlier reported PMUTs designed for bandwidth enhancement, the proposed broadband MF-PMUT array is much simpler in design and fabrication, revealing it as a promising candidate for short-distance high-accuracy measurements.
Precise viscosity measurement in liquid media remains a critical challenge for micromachined resonant sensors. This primarily results from the inherent coupling between viscosity and density in hydrodynamic interactions, which limits independent quantification of viscosity. This work presents an aluminum nitride (AlN) piezoelectric microresonator vibrating at in-plane lateral mode for direct viscosity sensing in liquids. The resonator features cantilevered dual-plate structure with a wide step to leverage width-dependent effects on resonant frequency and quality factor. Through fluid-structure interaction modeling, the resonator is optimized to enhance vibrational characteristics while increasing linearity with respect to liquid viscosity. In experiments, the resonator incorporates fully electrical interfaces by combining self-actuation and self-sensing capabilities under liquid immersion. Furthermore, a significantly linear relationship between the quality factor and liquid viscosity is demonstrated. This linearity enables direct viscosity quantification through simultaneously measuring the resonant frequency and quality factor, which eliminates the need for prior density calibration required by conventional methods. The fabricated resonator achieves a mean absolute relative deviation of 2.65% with a maximum stability deviation of 3.43%. These results establish microplate-based laterally vibrating resonators as promising solutions for high-precision viscosity determination in compact liquid monitoring systems.