Udo Wittmann

Mr. Udo Wittmann


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Foot and Ankle Surgery
Verified
Journal Article
Open access
MWMarkus Walther
Markus Walther
Victor ValderrabanoVictor Valderrabano
Victor Valderrabano
MWMartin Wiewiorski
Martin Wiewiorski
FUFederico Giuseppe Usuelli
Federico Giuseppe Usuelli
MRMartinus Richter
Martinus Richter
UWUdo Wittmann
Udo Wittmann
The aim of this study is to systematically review the literature on clinical outcomes of patients who have undergone autologous matrix-induced chondrogenesis (AMIC) for treatment of osteochondral lesions of the talus (OCL) and compare the studies' outcomes. Pubmed and Embase were searched in January 2020 for articles concerning OCL surgery. Studies were included if they had a minimum 1-year follow-up and the primary measures were functional outcomes. The meta-analysis compared the Visual Analogic Score (VAS), the American Orthopedic Foot and Ankle Score (AOFAS), and the Foot Function Index (FFI) between baseline and follow-up of 1-2years, and 3-5years. A random effects model was used to evaluate outcome changes. The search returned 15 studies, with a total of 492 patients. The VAS improved 4.45 and 4.6 points from baseline to the 1-2year and 3-5yearfollow-up, respectively (p<0.001). AOFAS improved 31.59 and 32.47 points from baseline to the 1-2year and 3-5yearfollow-up, respectively (p<0.001). The FFI showed a significant improvement of 30.93 points from baseline to year 3-5 (p<0.001). A total of 6 patients with revision surgeries have been reported within the follow up period. It was not possible to correlate clinical features like lesion size, surgical approach, and bone marrow stimulation technique to the reported outcome. Surgical treatment of OCL via the AMIC procedure provided significant improvement in the functional outcome and pain scores when compared to the pre-operative values. Improvements were observed up to 5years post-operatively.

22 July 2021 in British Journal of Nursing
Verified
Journal Article
Closed access
MNMatthias Alexander Neusser
Matthias Alexander Neusser
IBIrina Bobe
Irina Bobe
AHAnne Hammermeister
Anne Hammermeister
UWUdo Wittmann
Udo Wittmann
HIGHLIGHTS: 2% taurolidine catheter lock solution without additives is safe and efficient. CRBSI and dysfunction rates compare favorably against other studies in hemodialysis Background: In hemodialysis patients, catheter-related bloodstream infection (CRBSI) and catheter dysfunction are common and cause significant morbidity, mortality, and costs. Catheter lock solutions reduce CRBSI and catheter dysfunction rates, but solutions containing heparin, citrate, or antibiotics are associated with adverse effects. Due to its antimicrobial and antithrombotic properties and benign safety profile, taurolidine is suitable for use in catheter lock solutions. In this study the effectiveness and safety of a catheter lock solution containing 2% taurolidine without citrate or heparin (TauroSept®, Geistlich Pharma AG, Wolhusen, Switzerland) in hemodialysis patients were investigated for the first time. Methods: Data from 21 patients receiving chronic hemodialysis via tunneled central venous catheters with 2% taurolidine solution as a catheter lock were analyzed in a single-center retrospective study and compared with the existing literature in a review. The primary endpoint was CRBSI rate. Secondary endpoints included catheter dysfunction, treatment, and costs; catheter technical problems, resolution, and costs; and adverse events. Data were compared to outcomes with standard lock solutions in the literature. Results: No CRBSIs occurred during the observation period of 5,639 catheter days. The catheter dysfunction rate was 0.71 per 1,000 catheter days, and the catheter dysfunction treatment costs were CHF (Swiss Franc) 543 per patient. No technical problems or adverse events related to the use of 2% taurolidine-containing catheter lock solution were observed. These results compare favorably with other catheter lock solutions. Conclusions: A solution containing 2% taurolidine seems suitable as a hemodialysis catheter lock. In a Swiss cohort, it prevented CRBSI, limited catheter dysfunction, and was cost-efficient.

25 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
MSMalin Strasding
Malin Strasding
ISIrena Sailer
Irena Sailer
EMElizabeth Merino-Higuera
Elizabeth Merino-Higuera
CZCristina Zarauz
Cristina Zarauz
JPJoao Pitta
Joao Pitta
Dobrila NesicDobrila Nesic
Dobrila Nesic
Background: Tooth loss results in hard- and soft-tissue volume loss over time. We compared the handling of three different soft tissue substitutes (STS) to the subepithelial connective tissue graft (SCTG) for soft tissue volume augmentation in a pig ex vivo model. Methods: Five dentists simultaneously shaped, placed and sutured randomized four graft types in single-tooth soft tissue defects created in pig mandibles. The STS, produced from slightly crosslinked collagen fibres (VCMX), were either 3 mm or 6 mm thick blocks or a newly developed pre-customized saddle-shape. Each graft type was handled 20 times. The time required for shaping, placement, and suturing was recorded. Dentists reported outcomes on the grafts’ handling were evaluated with a visual-analogue-scale (VAS). Statistical analysis included calculating means and medians and testing significance. Results: The mean time of 0.72 min for shaping the pre-customized saddle-shape STS was significantly lower than 1.31 min for SCTG, 1.73 min for 3 mm STS and 2.17 min for 6 mm STS. Placement/suturing time was similar for all grafts. The dentists mainly preferred the saddle-shape STS and the SCTG. Conclusions: The saddle-shape STS required less time for graft-shaping and, therefore, reduced the overall treatment time, suggesting a more efficient and less invasive workflow for soft tissue augmentation.