Dandan Zhang

Dr. Dandan Zhang


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RYRuilin Yang
Ruilin Yang
DZDandan Zhang
Dandan Zhang
ZLZhenbiao Li
Zhenbiao Li
KYKai Yang
Kai Yang
SMShi Mo
Shi Mo
LLLi Li
Li Li
An on-load tap changer (OLTC) is one of the most error-prone parts in the transformer. The stability of the entire power system will be greatly threatened if the OLTC fails. It is necessary to diagnose the mechanical fault of OLTCs. At the same time, the mechanical fault signals are not easy to collect during practical application. It is desirable to have indicators that help to access the condition of the OLTC with a small number of fault samples. This paper describes a strategy for distinguishing different mechanical diagnostics of OLTCs based on dynamic time warping. By synchronization, framing, and Fourier transform, the signal can be represented by an energy matrix, which can be used to distinguish different conditions of the OLTCs and shows the severities of the fault. Some simulated experiments are designed and in order to make the simulations close to reality, all experiments are taken in a tank which is filled with transformer oil. These experiments demonstrate that the proposed approach can effectively diagnose different OLTC faults under different fault severities.

31 March 2023 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
GHGuobin Hou
Guobin Hou
DZDandan Zhang
Dandan Zhang
ZLZhenbiao Li
Zhenbiao Li
WPWenwu Pan
Wenwu Pan
ZWZhiyu Wan
Zhiyu Wan
YYYuwei You
Yuwei You
High-power DC relays are widely used in new energy power systems and DC distribution networks, and commonly use transverse magnetic fields to accelerate arc extinguishing. In this paper, the magnetically blown arc characteristics and the resulting contact erosion mechanisms of high-power DC relays are studied by experiments and simulations. The experiments are carried out to analyze the arc motion, contact erosion mass, and contact morphologies, and to verify the simulation model. Considering the energy transfer source term, the establishment of a more perfect magnetohydrodynamic arc model is accomplished, and an erosion model is further established. The results indicate that the magnetically blown arcing process has three stages while the arc shapes and motion characteristics are different, and the heat flux acting on the contact can be accurately obtained by the arc model. The greater external transverse magnetic field is more conducive to extinguishing the arc and reducing the arc erosion time. In contrast, the Archimedes force plays a very small positive role and the self-induced magnetic field of the arc has a negative effect. For contact erosion, the temperature distribution of the molten pool appears trailing effect. Moreover, the advanced mathematical model proposed for erosion mass has good accuracy. The calculation results of erosion rates show that Cr reduces erosion while the current increases erosion nonlinearly. Besides, the flow and deformation characteristics of the molten pool will lead to convex strip-shaped erosion traces and arcing position transfer, and the moving erosion will cause the lateral accretion effect. Furthermore, the analysis shows that the reason for edge droplet sputtering is the pressure difference caused by Plateau–Rayleigh instability, and optimization suggestions for reducing contact erosion are given.

9 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SMShi Mo
Shi Mo
DZDandan Zhang
Dandan Zhang
ZLZhenbiao Li
Zhenbiao Li
ZWZhiyu Wan
Zhiyu Wan
This study develops a technique to extract the wave propagation properties of power cables from impedance spectroscopy. This method extracts the propagation constant, characteristic impedance, phase velocity, and RLGC Telegrapher’s Equation parameters. The current study first proposes an initial method to extract high-frequency cable transmission characteristics by the impedance spectroscopy of open- and short-ended cables. Using this method, the propagation constant and phase velocity can be extracted accurately. However, the initial method is still problematic. The waveform of characteristic impedance is distorted due to the additional impedance of connection wire between measuring devices and the tested cable. Therefore, this study proposes a modified method, which can eliminate the influence of additional impedance and acquire the high-frequency cable transmission characteristics accurately. By obtaining the series impedance from cable geometry parameters and getting the propagation constant from impedance spectroscopy, the modified method can obtain the characteristic impedance by combining the series impedance and the propagation constant. The extraction is demonstrated for a YJV-8.7/15 kV-1*35 XLPE cable in the frequency range 300 kHz–100 MHz.

1 July 2016 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
YLYaqing Liu
Yaqing Liu
DZDandan Zhang
Dandan Zhang
ZLZhenbiao Li
Zhenbiao Li
QHQinqing Huang
Qinqing Huang
BLBin Li
Bin Li
JLJian Liu
Jian Liu
In this paper, a correction method is introduced to make a more accurate calculation of winding eddy‐current losses of high‐voltage direct current (HVDC) converter transformer. The assumption that winding eddy‐current losses of HVDC converter transformers follow the frequency with the exponent 2 proposed by IEC 61378‐2 Std. is thought to be inappropriate and the skin effect should be taken into consideration. The frequency characteristic of winding eddy‐current losses is proposed by analysing the distribution of magnetic flux in conductors, in which skin effect is taken into consideration. The correction method with a correction factor is then introduced to correct the assumption. To verify the validity of the correction method, a two‐dimension axisymmetric finite element analysis of a HVDC converter transformer is conducted. The geometrical complexity of windings and electrical connection are fully taken into account, it is shown that the correction method shows a significant advantage. Influence of different methods is revealed by applying the actual non‐sinusoidal load current and it is shown that the error of correction method is the least. At last, harmonic losses measurements are conducted on three coils to investigate the limits of the correction method.

3 July 2024 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
GHGuobin Hou
Guobin Hou
DZDandan Zhang
Dandan Zhang
ZLZhenbiao Li
Zhenbiao Li
ZWZhiyu Wan
Zhiyu Wan
KSKexin Shi
Kexin Shi
It is of great significance to clarify the influence of transverse magnetic field (TMF) on arc control in high-voltage direct current (HVDC) relays. In this paper, the influence of TMF in a wide range of 0–140 mT on the arc characteristics of HVDC relays is studied, the experimental observations of arc reignition are carried out and the effect of arc reignition on contact erosion, the criterion of arc reignition and the mechanism of TMF enhancement on arc reignition are further analyzed. The results show that the TMF enhancement is beneficial for shortening the arc voltage stagnation duration and accelerating the speed of arc elongation, arc dispersion and dispersed arc motion, thereby improving the arc extinguishing performance. However, higher TMF leads to more severe and earlier arc reignition, as also shown in the experimental observations. The arc reignition further causes a sudden drop in arc voltage, prolonged arc duration and uneven contact erosion. To evaluate the occurrence of arc reignition caused by TMF enhancement, a simplified breakdown criterion is proposed through the defined characteristic variable C ¯ ( t ) . Based on this, the mechanism by which the TMF enhancement more easily causes arc reignition is explained, that is the higher TMF leads to an earlier and faster increase in C ¯ ( t ) and slightly reduces the breakdown threshold C ¯ ∗ ( t 5 , D ) . Further, measures to suppress the arc reignition are proposed.

6 December 2017 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Open access
DTDixin Tan
Dixin Tan
BWBin Wang
Bin Wang
XLXuhui Li
Xuhui Li
XCXiaonan Cai
Xiaonan Cai
DZDandan Zhang
Dandan Zhang
YXYihua Xu
Yihua Xu
Multidrug-resistant tuberculosis (MDR-TB) has become a major public health problem. We tried to apply the classification tree model in building and evaluating a risk prediction model for MDR-TB. In this case–control study, 74 newly diagnosed MDR-TB patients served as the case group, and 95 patients without TB from the same medical institution served as the control group. The classification tree model was built using Chi-square Automatic Interaction Detectormethod and evaluated by income diagram, index map, risk statistic, and the area under receiver operating characteristic (ROC) curve. Four explanatory variables (history of exposure to TB patients, family with financial difficulties, history of other chronic respiratory diseases, and history of smoking) were included in the prediction model. The risk statistic of misclassification probability of the model was 0.160, and the area under ROC curve was 0.838 (P < 0.01). These suggest that the classification tree model works well for predicting MDR-TB. Classification tree model can not only predict the risk of MDR-TB effectively but also can reveal the interactions among variables.