Renan Borelli Galvão

Dr. Renan Borelli Galvão


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2020 in Environmental Technology
Verified
Journal Article
Closed access
RGRenan Borelli Galvão
Renan Borelli Galvão
AMAndressa Algayer da Silva Moretti
Andressa Algayer da Silva Moretti
FFFernando Fernandes
Fernando Fernandes
EKEmília Kiyomi Kuroda
Emília Kiyomi Kuroda
Stabilized leachates from sanitary landfills generally display high levels of recalcitrant organic matter, sometimes requiring a combination of biological and physicochemical treatment processes. This study evaluated the post-treatment by Upflow Gravel Filtration (UGF) followed by Granular Activated Carbon Adsorption (GACA) on a pilot scale of two different landfill leachates previously treated by biological processes. The system design was proven technically feasible for a continuous flow post-treatment in relation to recalcitrant organic matter removal efficiency. The UGF experiments presented 83.9 and 82.0% COD removals for leachates A and B, respectively, with residual values ⁣⁣of 107 and 194 mg L-1. The UGF-GACA experiments, in turn, produced effluents with residual COD values ⁣⁣of 67 and 94.6% efficiencies.

23 March 2020 in Revista DAE
Verified
Journal Article
Open access
RGRenan Borelli Galvão
Renan Borelli Galvão
PBPriscila Liane Biesdorf Borth
Priscila Liane Biesdorf Borth
FFFernando Fernandes
Fernando Fernandes
EKEmília Kiyomi Kuroda
Emília Kiyomi Kuroda
A incorporação de lixiviado de aterro sanitário no tratamento de esgoto doméstico tem sido praticada em alguns países e pode ser uma alternativa técnica interessante, desde que o transporte do lixiviado à ETE seja viável e que a mesma tenha capacidade de absorver a sobrecarga. Este trabalho buscou avaliar os impactos da adição de lixiviado de aterro sanitário pré-tratado por stripping de amônia no tratamento de esgoto doméstico em reatores anaeróbios UASB. A avaliação foi realizada em escala piloto, em reatores com volume de 14,14 L, vazão de 1,77 L h-1 e TDH de 8 h. O tratamento das misturas esgoto-lixiviado foi eficiente na remoção de DQO, apresentando remoções entre 69,2 e 81,4%, com valores residuais de 88 a 168 mg L-1. A análise dos incrementos de DQO provenientes do lixiviado sugeriu que o tratamento anaeróbio não foi capaz de remover a DQO adicionada e ainda foi prejudicado em relação à remoção da DQO biodegradável do esgoto.

1 May 2019 in Engenharia Sanitaria e Ambiental
Verified
Journal Article
Open access
EFEduardo Hideo Fujii
Eduardo Hideo Fujii
RGRenan Borelli Galvão
Renan Borelli Galvão
JRJosemarque Lima Rosa
Josemarque Lima Rosa
FFFernando Fernandes
Fernando Fernandes
EKEmília Kiyomi Kuroda
Emília Kiyomi Kuroda
RESUMO O lixiviado de aterro sanitário apresenta composição variável e complexa e pode ter elevadas concentrações de nitrogênio amoniacal e matéria orgânica biodegradável e recalcitrante. Devido ao potencial altamente poluidor dos lixiviados estabilizados, além do tratamento biológico convencional, faz-se necessária, em alguns casos, a realização de pós-tratamento para remoção da matéria orgânica recalcitrante, de maneira a atender à legislação vigente. Nesse contexto, os ensaios de coagulação seguida de filtração ascendente em pedregulho como pós-tratamento foram realizados com o objetivo de estabelecer a composição granulométrica que resultasse na melhor condição de eficiência em relação à remoção de matéria orgânica recalcitrante e operação, visando à aplicação do sistema em escala real. Para todos os ensaios, foram aplicados taxa de filtração constante de 15 m3.m-2.dia-1 e dosagem de ferro de 400 mg.L-1 em pH 4,0. A duração das carreiras de filtração, bem como a qualidade do efluente tiveram forte influência em relação à composição granulométrica do filtro, podendo-se constatar a necessidade do emprego de areia fina em sua composição, a fim de garantir a eficiência do tratamento. A concepção técnica de pós-tratamento por coagulação seguida da filtração ascendente com a composição granulométrica definida neste trabalho (tipo 4) foi eficiente para a remoção de matéria orgânica recalcitrante, com remoções de 82,4% de demanda química de oxigênio (valor residual de 194 mg.L-1), de 98,8% de cor verdadeira (valor residual de 49 uH), de 94,3% de carbono orgânico total (valor residual de 52 mg.L-1) e duração de carreira de filtração de 22,6 horas, sem ocorrência de transpasse.

4 December 2024 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
RGRenan Borelli Galvão
Renan Borelli Galvão
PBP. L. B. Borth
P. L. B. Borth
FFF. Fernandes
F. Fernandes
AFA. L. S. M. Felício
A. L. S. M. Felício
JFJ. A. de França
J. A. de França
EKE. K. Kuroda
E. K. Kuroda

3 July 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
AOAline Flores Onofre
Aline Flores Onofre
RGRenan Borelli Galvão
Renan Borelli Galvão
ATArthur Ribeiro Torrecilhas
Arthur Ribeiro Torrecilhas
NSNicole Schwantes-Cezario
Nicole Schwantes-Cezario
GCGabriel Trindade Caviglione
Gabriel Trindade Caviglione
MPMarcela Navarro Pianucci
Marcela Navarro Pianucci
Reinforced concrete is a constructive system widely used around the world. However, this constructive technique has constant failures and pathological manifestations. These problems may occur due to possible design flaws, mistakes in structural design, failures in execution process, as well as the lack of maintenance. Many researchers reported the high incidence of steel corrosion in reinforced concrete structures as one of the main pathological manifestations in all over the world. There is a lack of decision-making as to which manifestations need to be repaired urgently and which ones can wait for future repairs without aggravating the damage to the structure. Given this scenario, this work aimed to carry out a visual inspection in a reinforced concrete building, identifying its pathological manifestations and classifying these with the decision-making tool GUT (Gravity, Urgency, and Tendency). During the inspection generalized corrosion was identified in the reinforced concrete structural parts: slab, beams, and columns. By applying the GUT tool, it was possible to identify the priority of repairs on slabs, beams, and columns. The pathological manifestations observed were possibly caused by the incorporation of aggressive agents at the time of building the residence.

16 June 2026 in Bulletin of Environmental Contamination and Toxicology
Verified
Journal Article
Open access
PDF file
JPJandiara Damaris Campos Pozzetti
Jandiara Damaris Campos Pozzetti
RGRenan Borelli Galvão
Renan Borelli Galvão
VJVilson Gomes da Assunção Júnior
Vilson Gomes da Assunção Júnior
EKEmília Kiyomi Kuroda
Emília Kiyomi Kuroda
The isolated evaluation of physicochemical parameters of effluents in landfill leachate treatment is insufficient to determine reductions in acute or chronic toxicity to aquatic biota. Therefore, ecotoxicity tests are essential to assess environmental contamination. This study evaluated the ecotoxicological impacts, through acute and chronic tests on different organisms, of raw landfill leachate, leachate treated with ammonia stripping and activated sludge, and leachate post-treated by coagulation–flocculation–sedimentation (CFS) and adsorption using powdered activated carbon (PAC). Tests with P. subcapitata , C. dubia , D. magna , and A. salina indicated that biologically treated leachate exhibited lower toxicity than raw leachate. However, during post-treatment with CFS combined with PAC adsorption, despite the significant removal of recalcitrant compounds, toxicity increased for P. subcapitata , C. dubia , and D. magna , likely due to residual metals and chlorides from the coagulant and acidifier. Among the tested organisms, A. salina exhibited responses that differed from those of the other species, with a gradual decrease in toxicity observed after each treatment stage. This behavior may be partially associated with its marine origin and potential tolerance to chlorides.