Naresh Kumar Gunasekar

Dr. Naresh Kumar Gunasekar

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2012 in Physical Review Letters
Verified
Journal Article
Closed access
NGNaresh Kumar Gunasekar
Naresh Kumar Gunasekar
BHB. Hourahine
B. Hourahine
PEP. R. Edwards
P. R. Edwards
ADA. P. Day
A. P. Day
AWAimo Winkelmann
Aimo Winkelmann
CTCarol Trager-Cowan
Carol Trager-Cowan
We describe the use of electron channeling contrast imaging in the scanning electron microscope to rapidly and reliably image and identify threading dislocations (TDs) in materials with the wurtzite crystal structure. In electron channeling contrast imaging, vertical TDs are revealed as spots with black-white contrast. We have developed a simple geometric procedure which exploits the differences observed in the direction of this black-white contrast for screw, edge, and mixed dislocations for two electron channeling contrast images acquired from two symmetrically equivalent crystal planes whose g vectors are at 120\ifmmode^\circ\else\textdegree\fi{} to each other. Our approach allows unambiguous identification of all TDs without the need to compare results with dynamical simulations of channeling contrast.

6 November 2015 in Physical Review B
Verified
Journal Article
Open access
PDF file
SVS. Vespucci
S. Vespucci
AWAimo Winkelmann
Aimo Winkelmann
NGNaresh Kumar Gunasekar
Naresh Kumar Gunasekar
KMK. P. Mingard
K. P. Mingard
DMD. Maneuski
D. Maneuski
CTCarol Trager-Cowan
Carol Trager-Cowan
Electron backscatter diffraction is a scanning electron microscopy technique used to obtain crystallographic information on materials. It allows the nondestructive mapping of crystal structure, texture, and strain with a lateral and depth resolution on the order of tens of nanometers. Electron backscatter diffraction patterns (EBSPs) are presently acquired using a detector comprising a scintillator coupled to a digital camera, and the crystallographic information obtainable is limited by the conversion of electrons to photons and then back to electrons again. In this article we will report the direct acquisition of energy-filtered EBSPs using a digital complementary metal-oxide-semiconductor hybrid pixel detector, Timepix. We show results from a range of samples with different mass and density, namely diamond, silicon, and GaN. Direct electron detection allows the acquisition of EBSPs at lower (≤5 keV) electron beam energies. This results in a reduction in the depth and lateral extension of the volume of the specimen contributing to the pattern and will lead to a significant improvement in lateral and depth resolution. Direct electron detection together with energy filtering (electrons having energy below a specific value are excluded) also leads to an improvement in spatial resolution but in addition provides an unprecedented increase in the detail in the acquired EBSPs. An increase in contrast and higher-order diffraction features are observed. In addition, excess-deficiency effects appear to be suppressed on energy filtering. This allows the fundamental physics of pattern formation to be interrogated and will enable a step change in the use of electron backscatter diffraction (EBSD) for crystal phase identification and the mapping of strain. The enhancement in the contrast in high-pass energy-filtered EBSD patterns is found to be stronger for lighter, less dense materials. The improved contrast for such materials will enable the application of the EBSD technique to be expanded to materials for which conventional EBSD analysis is not presently practicable.

1 February 2017 in Acta Materialia
Verified
Journal Article
Open access
AVA. Vilalta-Clemente
A. Vilalta-Clemente
NGNaresh Kumar Gunasekar
Naresh Kumar Gunasekar
MNM. Nouf-Allehiani
M. Nouf-Allehiani
PGP. Gamarra
P. Gamarra
MFM.A. di Forte-Poisson
M.A. di Forte-Poisson
AWAngus Wilkinson
Angus Wilkinson
We describe the development of cross-correlation based high resolution electron backscatter diffraction (HR-EBSD) and electron channelling contrast imaging (ECCI), in the scanning electron microscope (SEM), to quantitatively map the strain variation and lattice rotation and determine the density and identify dislocations in nitride semiconductor thin films. These techniques can provide quantitative, rapid, non-destructive analysis of the structural properties of materials with a spatial resolution of order of tens of nanometers. HR-EBSD has a sensitivity to changes of strain and rotation of the order of 10^-4 and 0.01° respectively, while ECCI can be used to image single dislocations up to a dislocation density of order 10^10 cm^-2. In the present work, we report the application of the cross-correlation based HR-EBSD approach to determine the tilt, twist, elastic strain and the distribution and type of threading dislocations in InAlN/AlN/GaN high electron mobility transistors (HEMTs) structures grown on two different substrates, namely SiC and sapphire. We describe our procedure to estimate the distribution of geometrically necessary dislocations (GND) based on Nye-Kroner analysis and compare them with the direct imaging of threading dislocations (TDs) by ECCI. Combining data from HR-EBSD and ECCI observations allowed the densities of pure edge, mixed and pure screw threading dislocations to be fully separated

20 October 2020 in Physica Status Solidi (b)
Verified
Journal Article
Closed access
PDF file
NGNaresh Kumar Gunasekar
Naresh Kumar Gunasekar
HMHazel MacIntyre
Hazel MacIntyre
SSShanthi Subashchandran
Shanthi Subashchandran
Paul R. EdwardsPaul R. Edwards
Paul R. Edwards
Robert MartinRobert Martin
Robert Martin
AKAkito Kuramata
Akito Kuramata

12 November 2013 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
NGNaresh Kumar Gunasekar
Naresh Kumar Gunasekar
Jochen BruckbauerJochen Bruckbauer
Jochen Bruckbauer
Paul R. EdwardsPaul R. Edwards
Paul R. Edwards
SKSimon Kraeusel
Simon Kraeusel
BHBen Hourahine
Ben Hourahine
CTCarol Trager-Cowan
Carol Trager-Cowan
We combine two scanning electron microscopy techniques to investigate the influence of dislocations on the light emission from nitride semiconductors. Combining electron channeling contrast imaging and cathodoluminescence imaging enables both the structural and luminescence properties of a sample to be investigated without structural damage to the sample. The electron channeling contrast image is very sensitive to distortions of the crystal lattice, resulting in individual threading dislocations appearing as spots with black–white contrast. Dislocations giving rise to nonradiative recombination are observed as black spots in the cathodoluminescence image. Comparison of the images from exactly the same micron-scale region of a sample demonstrates a one-to-one correlation between the presence of single threading dislocations and resolved dark spots in the cathodoluminescence image. In addition, we have also obtained an atomic force microscopy image from the same region of the sample, which confirms that both pure edge dislocations and those with a screw component (i.e., screw and mixed dislocations) act as nonradiative recombination centers for the Si-doped c-plane GaN thin film investigated.

17 August 2015 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
GKGunnar Kusch
Gunnar Kusch
MNM. Nouf-Allehiani
M. Nouf-Allehiani
FMFrank Mehnke
Frank Mehnke
CKChristian Kuhn
Christian Kuhn
Paul R. EdwardsPaul R. Edwards
Paul R. Edwards
Robert MartinRobert Martin
Robert Martin
A series of Si-doped AlN-rich AlGaN layers with low resistivities was characterized by a combination of nanoscale imaging techniques. Utilizing the capability of scanning electron microscopy to reliably investigate the same sample area with different techniques, it was possible to determine the effect of doping concentration, defect distribution, and morphology on the luminescence properties of these layers. Cathodoluminescence shows that the dominant defect luminescence depends on the Si-doping concentration. For lower doped samples, the most intense peak was centered between 3.36 eV and 3.39 eV, while an additional, stronger peak appears at 3 eV for the highest doped sample. These peaks were attributed to the (VIII-ON)2− complex and the VIII3− vacancy, respectively. Multimode imaging using cathodoluminescence, secondary electrons, electron channeling contrast, and atomic force microscopy demonstrates that the luminescence intensity of these peaks is not homogeneously distributed but shows a strong dependence on the topography and on the distribution of screw dislocations.