Zhen Jiang

Dr. Zhen Jiang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 June 2020 in Journal of Chromatography A
Verified
Journal Article
Closed access
LZLi Zhou
Li Zhou
BLBeibei Liu
Beibei Liu
JGJin Guan
Jin Guan
ZJZhen Jiang
Zhen Jiang
XGXingjie Guo
Xingjie Guo

29 August 2017 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YDYueying Du
Yueying Du
LLLinda Luo
Linda Luo
SSShuo Sun
Shuo Sun
ZJZhen Jiang
Zhen Jiang
XGXingjie Guo
Xingjie Guo

18 March 2020 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
MLMeng Li
Meng Li
JZJunyuan Zhang
Junyuan Zhang
SMSiman Ma
Siman Ma
ZJZhen Jiang
Zhen Jiang
XDXin Di
Xin Di
XGXingjie Guo
Xingjie Guo
The chiral separation of five antihistamine drugs including meclizine, cloperastine, azelastine, carbinoxamine and mequitazine was studied by HPLC combined with chiral stationary phases. The effect of chiral columns, the types and contents of organic modifiers, and the concentrations of basic additive on the chiral separation was evaluated and optimized in detail. The best enantioselectivity for these compounds was observed using Chiralpak IA and Chiralpak ID as chiral columns. In particular, baseline separation of carbinoxamine with the largest resolution of 3.82 was achieved using a Chiralpak ID column with the mobile phase of acetonitrile–water–ammonia solution (90 : 10 : 0.1, v/v/v). Based on this result, an enantioselective HPLC-MS/MS method was developed and validated for determination of carbinoxamine enantiomers in rat plasma. Also, this method was successfully applied in evaluating the pharmacokinetic profiles of carbinoxamine enantiomers. Good linearity (r > 0.99) for both enantiomers over a concentration range of 0.1–100 ng mL−1 was obtained. The accuracy ranged from 87.4% to 113.8%, and the intra-day and inter-day precisions were below 9.4% for (+)- and (−)-carbinoxamine at three quality control levels. The pharmacokinetic parameters demonstrated that the absorption and elimination processes of carbinoxamine enantiomers were not stereoselective, and chiral inversion did not occur either in rats.


1 July 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
ZWZhaokun Wang
Zhaokun Wang
PZPengfei Zhao
Pengfei Zhao
BZBolin Zhu
Bolin Zhu
ZJZhen Jiang
Zhen Jiang
XGXingjie Guo
Xingjie Guo