Yasuko Yamada Maruo

Prof. Yasuko Yamada Maruo

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KIKatsuyuki Izumi
Katsuyuki Izumi
MUMasahiro Utiyama
Masahiro Utiyama
YMYasuko Yamada Maruo
Yasuko Yamada Maruo

1 January 2004 in Water, Air, & Soil Pollution
Verified
Journal Article
Closed access
PDF file
MUMasahiro Utiyama
Masahiro Utiyama
TFTsutomu Fukuyama
Tsutomu Fukuyama
YMYasuko Yamada Maruo
Yasuko Yamada Maruo
TIToshihiro Ichino
Toshihiro Ichino
KIKatsuyuki Izumi
Katsuyuki Izumi
MAMasatoshi Aoki
Masatoshi Aoki

21 January 2025 in ACS Sensors
Verified
Journal Article
Closed access
SMShuta Miura
Shuta Miura
KWKazuno Watanabe
Kazuno Watanabe
AKAkihiro Karashima
Akihiro Karashima
YMYasuko Yamada Maruo
Yasuko Yamada Maruo

8 April 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
YMYuto Muramatsu
Yuto Muramatsu
SWSota Watanabe
Sota Watanabe
MOMahiro Osada
Mahiro Osada
KTKohsuke Tajima
Kohsuke Tajima
AKAkihiro Karashima
Akihiro Karashima
YMYasuko Yamada Maruo
Yasuko Yamada Maruo
Acetone is a well-known biogas involved in lipid metabolism and is considered a potential biomarker for diabetes. However, the conventional detection methods for acetone face the limitations of large size, complex usage, and cross-sensitivity. In this study, we developed a portable device comprising a porous colorimetric acetone analytical chip composed of 2-nitrophenyl hydrazine and porous glass. The analytical chip was highly sensitive and selective for acetone because it was based on the chemical reaction between acetone and hydrazine in a nanoporous material, which provides a large surface area. The device consisted of a 450 nm laser light source and a photodiode detector with a volume of less than 40 mL. Acetone gas was measured in the atmosphere for 10 min using the developed flow–stop method. The measurable acetone concentration ranged from 0 to 6.0 ppm with a detection limit of 0.22 ppm. We successfully conducted a feasibility study using human exhaled breath and analyzed the relationship between exercise and the acetone concentration in the breath. An upward trend in exhaled acetone levels was seen post-exercise for each individual.

17 February 2023 in Talanta
Verified
Journal Article
Open access
YMYasuko Yamada Maruo
Yasuko Yamada Maruo
NKNaoto Kawamura
Naoto Kawamura
NANatsumi Abe
Natsumi Abe
Medium-chain aldehydes are common human biogases that can be detected in the breath of patients with lung diseases. As such, the measurement of medium-chain aldehyde gases in human breath can provide significant, noninvasive, and diagnostic information related to the potential presence of such diseases. In this study, an analytical chip is developed for the detection of medium-chain aldehydes without interference from short-chain aldehydes. This analytical chip is composed of porous glass impregnated with pararosaniline and an acid (i.e., acetic acid with small amount of phosphoric acid). After exposure to medium-chain aldehydes, the red analytical chip became violet in color, and an absorption peak was observed at 620 nm. It was found that a non-reversible reaction occurred in the porous glass, therefore, the analytical chip functions in a cumulative manner. A linear relationship was determined between the absorbance change of the analytical chip at 620 nm and the nonanal exposure concentration. Importantly, the developed analytical chip successfully detected nonanal at concentrations of 8-270 ppb as calculated from the absorbance change at 620 nm after a 24 h exposure time. In addition, nonanal concentration was estimated using the change in the R value of the analytical chip photograph. This method is suitable for point-of-care breath analysis. Finally, the analytical chip was also found to be active toward octanal and decanal with a relative sensitivity of 0.7 compared to that of nonanal; it was not active toward short-chain aldehydes.