Background: Complex molecular programs in specific cell lineages govern human heart development. Hypoplastic left heart syndrome (HLHS) is the most common and severe manifestation within the spectrum of left ventricular outflow tract obstruction defects occurring in association with ventricular hypoplasia. The pathogenesis of HLHS is unknown, but hemodynamic disturbances are assumed to play a prominent role. Methods: To identify perturbations in gene programs controlling ventricular muscle lineage development in HLHS, we performed whole-exome sequencing of 87 HLHS parent–offspring trios, nuclear transcriptomics of cardiomyocytes from ventricles of 4 patients with HLHS and 15 controls at different stages of heart development, single cell RNA sequencing, and 3D modeling in induced pluripotent stem cells from 3 patients with HLHS and 3 controls. Results: Gene set enrichment and protein network analyses of damaging de novo mutations and dysregulated genes from ventricles of patients with HLHS suggested alterations in specific gene programs and cellular processes critical during fetal ventricular cardiogenesis, including cell cycle and cardiomyocyte maturation. Single-cell and 3D modeling with induced pluripotent stem cells demonstrated intrinsic defects in the cell cycle/unfolded protein response/autophagy hub resulting in disrupted differentiation of early cardiac progenitor lineages leading to defective cardiomyocyte subtype differentiation/maturation in HLHS. Premature cell cycle exit of ventricular cardiomyocytes from patients with HLHS prevented normal tissue responses to developmental signals for growth, leading to multinucleation/polyploidy, accumulation of DNA damage, and exacerbated apoptosis, all potential drivers of left ventricular hypoplasia in absence of hemodynamic cues. Conclusions: Our results highlight that despite genetic heterogeneity in HLHS, many mutations converge on sequential cellular processes primarily driving cardiac myogenesis, suggesting novel therapeutic approaches.
Accidental injury to the cardiac conduction system (CCS), a network of specialized cells embedded within the heart and indistinguishable from the surrounding heart muscle tissue, is a major complication in cardiac surgeries. Here, we addressed this unmet need by engineering targeted antibody-dye conjugates directed against the CCS, allowing for the visualization of the CCS in vivo following a single intravenous injection in mice. These optical imaging tools showed high sensitivity, specificity, and resolution, with no adverse effects on CCS function. Further, with the goal of creating a viable prototype for human use, we generated a fully human monoclonal Fab that similarly targets the CCS with high specificity. We demonstrate that, when conjugated to an alternative cargo, this Fab can also be used to modulate CCS biology in vivo, providing a proof of principle for targeted cardiac therapeutics. Finally, in performing differential gene expression analyses of the entire murine CCS at single-cell resolution, we uncovered and validated a suite of additional cell surface markers that can be used to molecularly target the distinct subcomponents of the CCS, each prone to distinct life-threatening arrhythmias. These findings lay the foundation for translational approaches targeting the CCS for visualization and therapy in cardiothoracic surgery, cardiac imaging, and arrhythmia management.
28 February 2018 in European Journal of Cardio-Thoracic Surgery
Most patients (75%) with Marfan syndrome present with aortic root dilatation that may require surgical intervention. However, associated cardiovascular disorders are not limited to the aortic root. These patients frequently require consecutive operations on the remaining thoracic aorta or the heart valves. Our intent was to characterize the spectrum of such procedures. Data from all patients with Marfan syndrome undergoing aortic root surgery at our centre between 1988 and 2016 were analysed retrospectively. Overall, 73 patients (26 women) were selected for the study. The median age at 1st operation was 30 years (3–68 years). Indications for aortic root surgery were aneurysm (78%) and dissection (22%). Initially, 33 Bentall procedures and 40 valve-sparing root replacement procedures were performed, with a 97% rate of follow-up completion. The median follow up was 8 years (0–28 years). Survival at 1, 10 and 15 years was 100%, 85% and 82%, respectively. During follow-up monitoring, 48 subsequent procedures were performed in 33 patients (aorta, 23; aortic valve, 11; mitral valve, 7 and combined procedures, 7). The 30-day mortality rate after subsequent procedures was 4.2%. Freedom from subsequent operation and death (combined end-point) after 5, 10 and 15 years was 70%, 53% and 34%, respectively. After the initial surgery, subsequent procedures required in the setting of Marfan syndrome most often involve the remaining native aorta, followed by the aortic and mitral valves. The continued need for additional operative procedures remains high, even decades after the initial surgeries are undertaken. Therefore, long-term patient monitoring at specialized centres is imperative.
Background: The aim of this study was to evaluate the hemodynamic effect of different suturing techniques for aortic valve replacement (AVR) in vitro. Whether or not the applied suturing technique impacts the outflow tract diameter by narrowing the annulus diameter was examined. Methods: The commonly applied non-everting pledget forced suture technique (NE, n=13) was compared with an everting pledget forced suture (ET, n=13) for AVR using the 25 mm St. Jude Trifecta aortic valve. Hemodynamic parameters were obtained in a pulsatile flow simulator. A high speed camera captured the visual aspects of the suturing technique. Results: Despite some kind of left ventricular outflow narrowing due to protruding pledgets using the NE suture technique, mean pressure gradients of both techniques were nearly similar (NE 5.88±2.7 mmHg, ET 5.23±1.31 mmHg, P=0.44). Closing volume (NE 3.16±0.48 mL; ET 3.51±0.68 mL; P=0.14) and the leakage volume (NE: 8.09±2.53 mL; ET: 8.35±3.65 mL; P=0.83) also showed no differences. Conclusions: AVR using either suturing techniques leads to a similar hemodynamic performance in vitro. The impact of the suturing technique may be higher in a smaller annulus. Therefore, further studies using smaller prostheses are necessary.