Reem Amine

Dr. Reem Amine


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Justis P. EhlersJustis P. Ehlers
Justis P. Ehlers
SYSari Yordi
Sari Yordi
HCHasan Cetin
Hasan Cetin
RAReem Amine
Reem Amine
KMKaren Matar
Karen Matar
SSSunil K. Srivastava
Sunil K. Srivastava
Background/Objectives: To investigate the effect of ellipsoid zone (EZ) integrity and retinal fluid on best-corrected visual acuity (BCVA) in neovascular, age-related macular degeneration. Methods: This was a post hoc treatment-agnostic analysis of the phase 3 HAWK trial. Intraretinal fluid (IRF), subretinal fluid (SRF), and ellipsoid zone (EZ) integrity were quantified over 48 weeks. EZ integrity maintenance was defined as EZ-RPE central subfield thickness (CST) >20 µm; partial EZ attenuation was EZ-RPE CST >0 and ≤20 µm; total EZ attenuation was EZ-RPE CST = 0 µm. Results: During treatment, BCVA in eyes with no fluid (66.5 to 70.2 letters) was greater than in eyes with IRF (59.5 to 62.4 letters) but comparable to BCVA in eyes with SRF (64.9 to 68.8 letters). In eyes with no fluid, BCVA was consistently greater in eyes with EZ integrity maintained (73.4 to 78.4 letters) than in eyes with EZ partial attenuation (65.3 to 66.5 letters) or with EZ total attenuation (55.8 to 59.8 letters). Conclusions: Eyes without fluid with EZ preservation achieved the highest overall BCVA, especially when compared to eyes without fluid and a lack of EZ preservation and to eyes with SRF. Achieving a “dry” status with preservation of EZ integrity is important in optimizing visual outcomes.

30 May 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MMMasaharu Mizuno
Masaharu Mizuno
KMKaren Matar
Karen Matar
RAReem Amine
Reem Amine
KTKatherine E. Talcott
Katherine E. Talcott
JGJeffrey M. Goshe
Jeffrey M. Goshe
Justis P. EhlersJustis P. Ehlers
Justis P. Ehlers
Objectives: to evaluate the feasibility and utility of intraoperative optical coherence tomography (iOCT) utilizing an immersive augmented reality surgical headset (Beyeonics iOCT, Beyeonics Vision Ltd., Haifa, Israel) digital visualization platform with swept-source integrated OCT in ophthalmic surgery. Methods: As part of the Institutional Review Board-approved prospective DISCOVER study, the Beyeonics iOCT was utilized in multiple ophthalmic surgical procedures to evaluate the feasibility and utility of iOCT with this platform. The Beyeonics iOCT is a three-dimensional surgical visualization system that utilizes a swept-source integrated OCT within the digital microscope system. Surgeon feedback on system performance and integration into the surgical workflow was gathered via a prespecified survey. Results: Thirteen eyes of thirteen patients were included in this study. The surgical procedures consisted of four cataract surgeries, two lamellar corneal transplants, one pterygium removal, and six vitreoretinal surgeries. Surgeons were able to successfully view and review the iOCT images within the surgical Head-Mounted Display, eliminating the need for an external display. Utility feedback from surgeons included iOCT assisting with confirming wound architecture, corneal graft orientation, and retinal structure. All surgeries were completed without reverting to a conventional microscope, and no intraoperative adverse events occurred. Conclusions: The new visualization platform with integrated swept-source iOCT demonstrated feasibility and potential utility in multiple ophthalmic surgical platforms. Additional research related to outcomes, ergonomics, and enhanced software analysis is needed in the future.