Mathieu Charbonneau

Mr. Mathieu Charbonneau


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MSMatthew Slopecki
Matthew Slopecki
MCMathieu Charbonneau
Mathieu Charbonneau
JLJean-Michel Lavallière
Jean-Michel Lavallière
JCJulie Cote
Julie Cote
JCJulien Clément
Julien Clément
Biomechanics and training load monitoring are important for performance evaluation and injury prevention in elite swimming. Monitoring of performance and swim stroke parameters is possible with inertial measurement units (IMU) but has not been validated in para-swimmers. The purpose of this study was to validate a single IMU-based system to accurately estimate pool-swam lap time, stroke count (SC), stroke duration, instantaneous stroke rate (ISR), and distance per stroke (DPS). Eight Paralympic athletes completed 4 × 50 m swims with an IMU worn on the sacrum. Strokes cycles were identified using a zero-crossing algorithm on the medio-lateral (freestyle and backstroke) or forward-backward (butterfly and breaststroke) instantaneous velocity data. Video-derived metrics were estimated using Dartfish and Kinovea. Agreement analyses, including Bland–Altman and Intraclass Correlation Coefficient (ICC), were performed on all outcome variables. SC Bland–Altman bias was 0.13 strokes, and ICC was 0.97. ISR Bland–Altman biases were within 1.5 strokes/min, and ICCs ranged from 0.26 to 0.96. DPS Bland–Altman biases were within 0.20 m, and ICCs ranged from 0.39 to 0.93. A single-IMU system can provide highly valid performance and swim stroke monitoring data for elite para-swimmers for the majority of strokes, with the exception of backstroke. Future work should improve bilateral stroke detection algorithms in this population.

19 November 2018 in Sports
Verified
Journal Article
Open access
PDF file
FRFrançois Raymond
François Raymond
BLBenoit Lussier
Benoit Lussier
FDFrançois Dugas
François Dugas
MCMathieu Charbonneau
Mathieu Charbonneau
FCFelix Croteau
Felix Croteau
NBNicolas Berryman
Nicolas Berryman
The purpose of this study was to verify the metrological properties of portable force plates that are used to assess countermovement jump performance. While 88 participants (38 males, 50 females) were included in the agreement analyses, 84 participants (37 males and 47 females) completed the reliability part of the study. This randomized crossover design suggests that portable force plates could be used interchangeably with a reference system. Indeed, the differences between both devices were all considered trivial (effect size (ES) < 0.20), and the mean bias was never greater than 3.41% in comparison to the reference system. In addition, the absolute and relative reliability parameters were found to be acceptable for clinical use, even when used on different floor surfaces. However, it was found that the ratio between flight time and contraction time (FTCT) showed questionable reliability when tests were conducted on different surfaces (intraclass correlation coefficient = 0.49; coefficient of variation = 26.72%). Therefore, practitioners should be careful when installing the portable device on different floor surfaces in order to optimize the reliability and the ability to detect real change in the context of a countermovement jump monitoring process.

24 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MSMatthew Slopecki
Matthew Slopecki
JCJulien Clément
Julien Clément
MCMathieu Charbonneau
Mathieu Charbonneau
JCJulie Cote
Julie Cote
Wearable technology can nowadays be used to improve para-swimming coaching; however, the extent to which individual anatomy affects features of swimming variability is unclear. Six paralympic swimmers were recruited, their upper-limb segment lengths were measured, and their absolute bilateral limb asymmetry indices (AbsLAIUL) were calculated. They were instrumented with a sacrum-worn inertial measurement unit and performed an in-water, fatiguing, freestyle aerobic test at incrementally faster paces. Stroke-to-stroke outcome and execution variability were calculated, respectively, using sample entropy (SampEn) and fractal dimension (FD) on forward and mediolateral linear acceleration signals. Significantly increased perceived exertion scores (F(4,28) = 154.1, p < 0.001) were observed. Execution and outcome variability increased in the forward (SampEn = F(4,25) = 11.86, p < 0.001; FD = F(4,24) = 6.17, p = 0.001) and mediolateral (SampEn = F(4,25) = 9.46, p < 0.001; FD = F(4,24) = 27.64, p < 0.001) directions. Modelling of FD (only) improved with AbsLAIUL as a covariate (forward = F(1,24) = 9.68, p = 0.005; mediolateral = F(1,24) = 8.57, p = 0.021), suggesting that AbsLAIUL affects only execution, but not outcome, variability. This information could help coaches determine which coordination indices should be personalized when monitoring variability during para-swimming training.