Huang Chun

Huang Chun


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PLPenghui Liu
Penghui Liu
HCHuang Chun
Huang Chun
In neutral ineffectively grounded distribution systems, a conventional zero-sequence voltage criterion to detect a single-phase-to-ground (SPG) fault event suffers from some drawbacks, and existing fault feeder selection techniques demonstrate low reliability in the field. For improvement, a new protection scheme is proposed in this paper. It is composed of a fault event detection unit and a fault feeder identification unit. Based on data distribution kurtosis of transient zero-sequence current, the former unit is employed to detect whether a SPG fault event has occurred and capture a fault starting moment. According to the behavior of average data distribution skewness, the latter unit is employed to identify which feeder is faulty. Superior to the zero-sequence voltage criterion, the proposed scheme can reliably detect the SPG fault event under a three-phase voltage imbalance condition and intermittent arc grounding fault. Besides, it is also found that the proposed scheme can validly identify a faulty feeder even under high background noises. Case test results indicate that the proposed scheme is able to work well with not only simulation data but also recorded field data, which demonstrates the high value in engineering practice.

23 July 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YYYachao Yang
Yachao Yang
HCHuang Chun
Huang Chun
QXQianming Xu
Qianming Xu
This paper presents a fault location method suitable for low-voltage dc line. To estimate the fault location of dc lines, a fault location module is designed, and it is connected to each end of dc lines. When dc lines fail, the dc circuit breaker is tripped quickly, and the residual current of the dc line inductance is still flowing through the fault location module. Considering attenuation of the dc line inductance current, which is a function of the fault distance and fault resistance, the fault location algorithm is established. A simplified dc microgrid model is built by PSCAD/EMTDC, and the proposed method is simulated by MATLAB. The results show that the proposed method can accurately locate the fault point of dc lines. In addition, the proposed method is also verified on a small-scale hardware experiment platform.

6 July 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HCHuang Chun
Huang Chun
XXXing Xie
Xing Xie
HJHui Jiang
Hui Jiang
This paper presents a double suboptimal-scaling-factor adaptive strong tracking Kalman filter (DSTKF)-based phasor measurement unit algorithm which can meet the accuracy requirement of the IEEE standard C37.118.1 under the dynamic condition. This method uses a kth Taylor polynomial to linearize the complex exponential of the signal model, and estimates the dynamic phasor using DSTKF. The antialias filter unit for DSTKF algorithm is included to suppress high-order harmonics which will augment computing burden. By applying double suboptimal-scaling factors, DSTKF adjusts the process noise covariance matrix and the prediction covariance matrix in real time. Thereafter, amplitude and frequency measurement performances under various dynamic conditions are assessed in detail. Theoretical analysis and comprehensive experimental results validate the effectiveness of the proposed method.

1 June 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
XXXing Xie
Xing Xie
WXWen Xu
Wen Xu
HCHuang Chun
Huang Chun
XFXingming Fan
Xingming Fan

16 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WXWen Xu
Wen Xu
HCHuang Chun
Huang Chun
HJHui Jiang
Hui Jiang
Linear Kalman-filter-based phase-locked loop (LKF-PLL) has been widely applied in grid synchronization and other power system fields. It receives considerable attention for its fast startup transient which is superior to the traditional PLL. However, when the KF reaches its steady state, the Kalman gains will converge to constant values, which makes it degrade into the traditional synchronous reference frame phase-locked loop. The main aim of this article is to analyze the steady state of LKF-PLL and make a good use of its adaptive process. Based on the analysis, a design guideline of the LKF is introduced, which can help tune the Kalman gains separately to meet the engineering requirements. Besides, to enhance the dynamic performance under phase jump condition, a dynamic tracking algorithm-based LKF is proposed in this article. Comparative tests about phase detection in power system are conducted, and the results show that the proposed algorithm can greatly improve the dynamic response under phase jump condition without degrading its steady-state performance inherited by the traditional PLL.

16 July 2020 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
LJLi Jiang
Li Jiang
YHYuduo Huang
Yuduo Huang
YLYong Li
Yong Li
JYJiaqi Yu
Jiaqi Yu
XQXuebo Qiao
Xuebo Qiao
YCYijia Cao
Yijia Cao
This paper presents a variable-current charging strategy of Li-ion batteries. Since the battery characteristics vary with state of charge (SOC), it is more reasonable to divide the charging process based on SOC than on cut off voltage. We find an optimal charging pattern of the proposed strategy by Non-dominated Sorting Genetic Algorithm-III (NSGA-III). The Second-order Thevenin model of battery is established to simulate the charging process. Verification experiments are performed and results show that the obtained charging pattern has a temperature and loss reduction of 2.9 °C and 0.5% compared with constant current-constant voltage (CC-CV) strategy under the same charging time and capacity.