Cured-in-place-pipes (CIPP) are plastic liners chemically manufactured inside existing damaged sewer pipes. They are gaining popularity in North America, Africa, Asia, Europe, and Oceania. Volatile and semi-volatile organic compound (VOC/SVOC) emissions from storm sewer CIPP installations were investigated at a dedicated outdoor research site. Tedlar bag, sorbent tube, and photoionization detector (PID) air sampling was conducted for five steam-CIPP installations and was coupled with composite characterizations. New CIPPs contained up to 2.21 wt% volatile material and only 6-31% chemical mass extracted per CIPP was identified. Each 6.1 m [20 ft] liner contained an estimated 5-10 kg [11-22 lbs] of residual chemical. Extracted chemicals included hazardous air pollutants and suspected and known carcinogens that were not reported by others. These included monomers, monomer oxidation products, antioxidants, initiator degradation products, and a plasticizer. PID signals did not accurately represent styrene air concentration differing sometimes by 10s- to 1000s-fold. Multiple VOCs found in air samples likely affected PID responses. Styrene (>86.4 ppmv) and methylene chloride (>1.56 ppmv) air concentrations were likely greater onsite and phenol was also detected. Additional studies are needed to examine pollutant emissions so process monitoring can be improved, and environment impacts and associated human exposures can be minimized.
Storm water culverts are integral for U.S. public safety and welfare, and their mechanical failure can cause roadways to collapse. To repair these buried assets, ultraviolet (UV) light cured-in-place-pipes (CIPP) are being installed. Chemical emission and residual material left behind from the installation process was investigated in New York and Virginia, USA. Samples of an uncured resin tube and field-cured styrene-based resin CIPPs were collected and analyzed. Also collected were air and water samples before, during, and after installations. Chemicals were emitted into air because of the installation and curing processes. Particulates emitted into the air, water, and soil contained fiberglass, polymer, and contaminants, some of which are regulated by state-level water quality standards. The uncured resin tube contained more than 70 chemical compounds, and 19 were confirmed with analytical standards. Compounds included known and suspected carcinogens, endocrine disrupting compounds, hazardous air pollutants, and other compounds with little aquatic toxicity data available. Compounds (14 of 19 confirmed) were extracted from the newly installed CIPPs, and 11 were found in water samples. Aqueous styrene (2.31 mg/L), dibutyl phthalate (12.5 μg/L), and phenol (16.7 μg/L) levels exceeded the most stringent state water quality standards chosen in this study. Styrene was the only compound that was found to have exceed a 48 h aquatic toxicity threshold. Newly installed CIPPs contained a significant amount volatile material (1.0 to > 9.0 wt%). Recommendations provided can reduce chemical emission, as well as improve worksite and environmental protection practices. Recommended future research is also described.