Michael Jacobs

Michael Jacobs


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
HJHouman Jalaie
Houman Jalaie
JGJ. Grommes
J. Grommes
ASA. Sailer
A. Sailer
AGA. Greiner
A. Greiner
MBM. Binnebösel
M. Binnebösel
MJMichael Jacobs
Michael Jacobs

17 February 2012 in Journal of Vascular Surgery
Verified
Journal Article
Open access
PDF file
AGAndreas Greiner
Andreas Greiner
WMWerner H. Mess
Werner H. Mess
JSJuerg Schmidli
Juerg Schmidli
EDEike S. Debus
Eike S. Debus
JGJochen Grommes
Jochen Grommes
MJMichael Jacobs
Michael Jacobs
Objective This study assessed the feasibility and effectiveness of remote neuromonitoring as an adjunct to spinal cord protection during surgical repair of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms. Methods Four aortic centers in three European countries participated in this prospective observational study. A similar surgical protocol was used in all centers, including assessment of spinal cord function by means of monitoring motor-evoked potentials (MEPs). MEP information was evaluated at one central neurophysiologic department in Maastricht, The Netherlands. Transfer of MEP data from all operating rooms to Maastricht was arranged by Internet connections. In all patients, the protective and surgical strategies to prevent paraplegia were based on MEPs. The on-site surgeons reacted in real time to the interpretation and feedback of the neurophysiologist. Results Between March 2009 and May 2011, 130 patients (85 men) were treated by open surgical repair. Extent of aneurysms was equally distributed among the centers. Neuromonitoring was technically stabile and successful in all patients. The transfer of data from the operating room in the different vascular centers was undisturbed and without any technical problems. By maintaining a mean distal aortic pressure of 60 mm Hg, MEPs were undisturbed in 65 patients (50%). In another 65 patients (50%), significant changes in MEPs prompted the surgical teams to initiate additional protective and surgical strategies to restore spinal cord perfusion. These measures were not effective in five patients (3.8%), and acute paraplegia resulted. Delayed paraplegia occurred in 10 patients (7.7%) but improved in three and recovered completely in another three. No false-negative or false-positive MEP recordings were experienced. Conclusions Remote neuromonitoring of spinal cord function during open repair of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms as a telemedicine technique is feasible and effective. It allows centralization of expertise and saves individual centers from investing in complex technology. The value of monitoring MEPs was confirmed in different aortic centers, resulting in adequate neurologic outcome after extensive aortic surgical procedures.

1 July 2018 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
PKPaula R. Keschenau
Paula R. Keschenau
SKShirley Ketting
Shirley Ketting
BMBarend M.E. Mees
Barend M.E. Mees
Mohammad E. BarbatiMohammad E. Barbati
Mohammad E. Barbati
JGJochen Grommes
Jochen Grommes
MJMichael Jacobs
Michael Jacobs

25 September 2016 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
DKDrosos Kotelis
Drosos Kotelis
KSKarina Schleimer
Karina Schleimer
CFChristina Foldenauer
Christina Foldenauer
HJHouman Jalaie
Houman Jalaie
JGJochen Grommes
Jochen Grommes
JKJohannes Kalder
Johannes Kalder
Purpose: To report operative and midterm outcomes of fenestrated endovascular aneurysm repair (FEVAR) with the Anaconda device. Methods: A retrospective analysis was conducted of 39 consecutive patients (median age 74 years; 36 men) treated with the fenestrated Anaconda stent-graft between July 2011 and December 2015 at a single center. Indications for FEVAR were abdominal aortic aneurysms (AAAs) with neck anatomy unsuitable for a standard stent-graft. Median infrarenal neck length was 4 mm (range 0–9). Four (10%) patients presented with type IV thoracoabdominal aortic aneurysm (TAAA), 12 (31%) with suprarenal aneurysms, and 23 (59%) with juxtarenal aneurysms. Four (10%) patients had previous infrarenal aortic repair. Five (13%) patients had an infrarenal neck angulation >60°. A total of 106 fenestrations were incorporated into the stent-grafts (73 renal arteries, 25 superior mesenteric arteries, and 8 celiac trunks). Technical success, perioperative and midterm mortality and morbidity, target vessel patency, endoleaks, and reinterventions were documented. Results: Technical success was 95% (37/39). Three (8%) patients died in-hospital from mesenteric embolism in 2 and renal artery rupture with consequent multiorgan failure in 1. Two (5%) patients suffered an intraoperative embolic stroke. During a median follow-up of 33 months (range 4–55), adjunctive maneuvers were performed in 9 (23%) patients, including reintervention for type II endoleak with enlarged aneurysm sac in 2 (5%). Four additional patients died of causes unrelated to the aortic pathology (overall mortality 18%). In 34 (94%) of the 36 patients seen in follow-up, aneurysm sac size was stable or decreased. Target vessel stent patency was 99% (95/96). Conclusion: FEVAR with the Anaconda device delivers satisfactory short-term technical and clinical success rates in patients with juxtarenal, suprarenal, and type IV TAAA. Midterm efficacy and durability with respect to aneurysm sac regression and target vessel patency appear very good. Overall mortality and the need for reintervention were significant in this patient cohort.

9 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PDPanagiotis Doukas
Panagiotis Doukas
GHGabriel Hellfritsch
Gabriel Hellfritsch
Daniel WendtDaniel Wendt
Daniel Wendt
MMMirko Magliani
Mirko Magliani
Mohammad E. BarbatiMohammad E. Barbati
Mohammad E. Barbati
AGAlexander Gombert
Alexander Gombert
Background: The efficacy of cytokine adsorption in controlling the early inflammation cascade after open thoracoabdominal aortic (TAAA) repair has not been investigated. The aim of this pilot randomized controlled trial was to assess the feasibility and effect of perioperative hemoadsorption during open TAAA repair. Methods: Patients scheduled for open TAAA repair with the use of cardiopulmonary bypass (CPB) were included. The patients were randomized the day before surgery to either intraoperative hemoadsorption during CPB or standard of care. Results: A total of 10 patients were randomly assigned to the intervention group, whereas the control group consisted of 17 patients (mean age of the total cohort, 51.1 ± 11.2 years, 67% male, 3 patients not randomized). The majority of baseline and perioperative characteristics were similar, and no device-related adverse events were reported. A trend to shorter ventilation times in the intervention group was observed (median 88 h vs. 510 h, p = 0.08, Δ422). Severe acute respiratory distress syndrome was significantly less in the intervention patients (p = 0.02). Conclusions: This is the first pilot study showing that the intraoperative use of hemoadsorption in open TAAA repair patients may be feasible and safe, yet larger trials are needed to evaluate whether intraoperative hemoadsorption is associated with improved clinical outcomes.

5 July 2018 in Acta Veterinaria Scandinavica
Verified
Journal Article
Open access
PDF file
KSKarina Schleimer
Karina Schleimer
HJHouman Jalaie
Houman Jalaie
MAMamdouh Afify
Mamdouh Afify
AWAnna Woitok
Anna Woitok
Mohammad E. BarbatiMohammad E. Barbati
Mohammad E. Barbati
JSJulia Steitz
Julia Steitz
In vascular surgery, novel synthetic prosthesis materials for patch-angioplasties, interpositions, bypasses and shunts are continuously under development and optimization. The characteristics of an ideal vascular prosthesis would display long-term patency, biocompatibility, durability, low porosity, lack of stich hole bleeding, ease of handling, kink resistance, infection resistance and reasonable costs. The aim of this study was to establish and report a reliable sheep model including potential pitfalls where those parameters could be analyzed. Before surgery, sheep were acclimatized for 4–8 weeks, during which parasite infections were treated and blood and serum parameters monitored. Twenty-four sheep underwent surgery, and carotid patch-angioplasties (n = 12), graft interpositions (n = 6) or arteriovenous prosthetic shunts (n = 6) were implanted. Half of the animals in each group were sacrificed after 2 weeks and the other half after 8 weeks. The implants were analyzed for patency, endothelialization, thrombogenicity and biocompatibility by clinical observation, blood flow measurement and pathological and histopathological (H&E, EvG) as well as immunohistochemical (Ki67, CD31) evaluations. Health monitoring of the sheep revealed a parasitic burden with endoparasites in all animals. Some animals showed thereby infestations in the bile duct causing fibrotic cholangitis with calcifications in the liver. In addition, sarcosporidia were detected in histopathological specimen of the heart in all animals. Parasitic burden correlated with blood counts and serum bilirubin levels. Both were significantly reduced by albendazole treatment within the acclimatization time. Patches, interposition grafts, and straight shunts were successfully implanted bilaterally in all animals. The total average operation time was 136 ± 21 min. Most animals (23/24) showed good patency rates and general condition after implantation. Pathological and histopathological/immunohistochemical analyses were suitable to determine thrombogenicity, endothelialization, cellular/fibroblastic proliferation, biocompatibility, inflammatory cell infiltration, and thickness of neointima in the prosthesis material. We have developed a suitable experimental protocol with standardized and successful anesthesia- and surgical-procedures for patch-angioplasty, graft interposition, and arteriovenous prosthetic shunts. This sheep model allows testing of new prosthetic materials for biocompatibility, thrombogenicity, and endothelialization.