Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by dual X-ray absorptiometry (DXA). We have monitored 13 young AN subjects and 17 healthy controls of a similar age group using a Xitron 4200 multifrequency impedancemeter measuring extracellular (ECW) and total body water (TBW) volumes and a Tefal Bodymaster FFI measuring weight (W), fat-free-mass (FFM) and body fat mass (FM). This Tefal device has been modified to measure in addition ECW and TBW resistances permitting to calculate ECW and TBW volumes using appropriate algorithms. In addition FFM and FM were measured by DXA on AN subjects. FFM measured by the FFI and the Xitron in AN subjects were found to be respectively 7.8% and 4.5% lower than FFM measured by DXA. TBW measured by FFI was not significantly different from that measured by Xitron in AN subjects and in controls. ECW measured by the FFI was not significantly different from that measured by Xitron in controls, but was in AN subjects. The body cell mass to (height)2 ratio was found to be significantly different between AN subjects and controls. The modified FFI was found to be simpler and quicker to use than the Xitron, while giving similar information.
Breast cancer is the most common cancer observed in women. Although mammography is a recognized method, it remains ionizing and cannot be used routinely or in young adults, leaving up to two years between two diagnoses. Prior to validation on human subjects, this study aims to validate on phantoms the feasibility of quantifying breast density and detecting breast cancer tumors using a smart bra in young women. Six phantoms with various densities and seven phantoms with various volumes of modelized tumor were prepared and measured with a smart bra, including an electrophysiological module. There was a significant difference between the “healthy phantoms” and the “tumor phantoms” with P(Student) = 0.008 (Shapiro–Wilk p = 0.846, samples follow a normal distribution; Fisher variance test, p = 0.287). In addition, this study seems to indicate the possibility of discriminating various types of tumorous and healthy breast tissue using a smart bra, in high density breast. However, a new study on a large sample of human subjects will be required to generate new models, including resistive, capacitive, and other sensor parameters versus reference data collected from imaging.
The objective was to set-up a method for measuring total body water volumes (TBW) using a Tefal foot-to-foot impedancemeter (FFI) by comparison with a multifrequency medical impedancemeter and to validate this method against deuterium dilution data. The investigation was carried out in 57 Caucasian adult subjects. Impedancemeters were a Tefal Bodymaster Vision (foot-to-foot) featuring a square wave signal and a Xitron Hydra 4200 (5-1000 kHz) using BIS method. TBW was measured by the Xitron using a new method that we have developed which applies the BIS method directly to extra and intracellular fluids combined. Although the high frequency impedance of the FFI (R(hf)) was higher than the Xitron infinite frequency resistance and corresponded to a frequency around 100 kHz, TBW differences between the FFI and Xitron were not significant, 0.17+/-2.17 L for men (P=0.694) and 0.04+/-1.88 L for women (P=0.902). Then, our method was tested on another Caucasian population in which R(hf) had been measured with the same FFI, together with TBW measurements by deuterium dilution. TBW differences between the FFI and dilution were -0.38+/-2.27 L for men (P=0.237) and -0.72+/-2.37 L for women (P=0.06). Our method permits, at least in a Caucasian healthy population, to measure TBW using this FFI with the same accuracy as a whole body multifrequency medical impedancemeter, and the measurement, made in upright position, is much quicker.
Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is currently reached through a combination of several checks, mainly of the eyes’ fundus, tonometry and gonioscopy. Prior to validation for human subjects, the objective of this study is to validate whether ocular phantom-based models could be used to diagnose glaucoma using an onboard system, which could, even at home, prevent the early-stage development of the pathology. Eight phantoms modelling healthy eyes and eight phantoms modelling eyes with glaucoma due to excessive intraocular pressure were measured using an onboard system, including lens and electrophysiology electronics. We measured the actual average Zr (real part of impedance) impedance of 160.9 ± 24.3 ohms (glaucoma ocular phantom models) versus 211.9 ± 36.9 ohms (healthy ocular phantom models), and an average total water volume (Vt) of 3.02 ± 0.35 mL (glaucoma ocular phantom models) versus 2.45 ± 0.28 mL (healthy ocular Phantoms). On average, we obtained 51 ohms (−24.1%) less and 0.57 mL (22.9%) of total water volume more, respectively. Normality tests (Shapiro–Wilk) for Vt and Zr indicate p < 0.001 and p < 0.01, respectively. Since these variables do not respect normal laws, unmatched Mann–Whitney tests were performed indicating a significant difference between Vt and Zr in the healthy ocular phantom models and those modelling glaucoma. To conclude, this preliminary study indicates the possibility of discriminating between healthy eyes with those with glaucoma. However, further large-scale studies involving healthy eyes and those suffering from glaucoma are necessary to generate viable models.