Mustafa Çeltik

Dr. Mustafa Çeltik

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2024 in Medicine
Verified
Journal Article
Open access
MÇMustafa Çeltik
Mustafa Çeltik
Onur HapaOnur Hapa
Onur Hapa
SASelahaddin Aydemir
Selahaddin Aydemir
EAEren Akin
Eren Akin
AAAhmet Kaan Arslan
Ahmet Kaan Arslan
OGOnur Gürsan
Onur Gürsan
The correlation between clinical outcomes and preoperative/postoperative measures of the lateral center-edge angle (LCEA) will help establish the cutoff values for this measurement and determine whether to obtain it from the lateral acetabular rim (LCEAR) or the lateral end of the sourcil (LCEAS). The hypothesis was that the LCEAS would be more sensitive than the LCEAR. An upper cutoff value of LCEA could predict better functional outcomes in FAI patients. 106 patients (103 unilateral, 3 bilateral) who underwent hip arthroscopy surgery due to FAI and had a minimum 2-year follow-up were included. Patient-reported outcomes included the mHHS and visual analogue scale for pain (Pain VAS). Radiological parameters (alpha angle, LCEAS, LCEAR) were evaluated at the pelvis, 45° Dunn X-rays. A receiver operating characteristic analysis was used to evaluate the correlation between significant variables and achievement of patient-acceptable symptomatic state (PASS) and calculate area under the curve (AUC) and critical values for LCEA. The mean age of the patients was 34 ±10 years with a mean follow-up of 5 years. There were 75 male and 31 female patients. The mHHS improved from 57 ± 11 before surgery to 93 ± 8 after surgery (P < .001). The Pain VAS decreased from 6 before surgery to 1 after surgery (P < .001). A higher frequency of reaching the PASS threshold for mHHS was associated with lower preoperative and postoperative dunn LCEAS and postoperative dunn LCEAR. Preoperative dunn LCEAS ≤ 24.8° had an AUC of 0.67, predicting PASS (+) with 0.38 sensitivity and 0.93 specificity. Combining LCEAS with other parameters further improved predictability. LCEAS seems more predictive of clinical significance than LCEAR. However, predictivity exceeds the acceptable limit when they are measured together. The upper values for LCEAS and LCEAR seem to be 24° and 35°, respectively.

9 March 2021 in Cureus
Verified
Journal Article
Open access
OGOnur Gursan
Onur Gursan
MÇMustafa Çeltik
Mustafa Çeltik
BYBerkay YANIK
Berkay YANIK
RHR. Bugra Husemoglu
R. Bugra Husemoglu
HHHasan Havitcioglu
Hasan Havitcioglu
Joint-preserving prosthetic reconstruction for massive bone defects has the potential to be a new and revolutionary treatment option. In this paper, we discuss the case of a 30-year-old female patient who presented with pain and swelling around the knee for three months. The patient underwent this procedure. Postoperative patient satisfaction, pain scores, and range of motion results were found to be promising. We believe that this method has the potential to be the next stage in the quest for better treatment options for this condition.

7 October 2025 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
SASelahaddin Aydemir
Selahaddin Aydemir
CHCagri Havitcioglu
Cagri Havitcioglu
EAEren Akin
Eren Akin
MÇMustafa Çeltik
Mustafa Çeltik
FAFirat Aydin
Firat Aydin
Onur HapaOnur Hapa
Onur Hapa
Background: Labral reconstruction using various graft materials, including autografts and allografts, is gaining popularity to address labral deficiencies. However, the biomechanical effects of graft size, type, and fixation techniques remain underexplored. Purpose/Hypothesis: The purpose was to evaluate the effects of graft size, graft type, tubularization, and anchor number on suction seal force and distractive stability in an ovine hip model. It was hypothesized that larger graft sizes and the use of allografts would improve the suction seal force and distractive stability compared with smaller grafts and fewer anchor numbers, while tubularization would have no significant effect. Study Design: Controlled laboratory study. Methods: A total of 40 sheep hip joints were randomly assigned to 5 groups. Labral excision was performed, followed by reconstruction using autografts or allografts. Ovine extensor tendons were chosen as autografts, whereas labrums from a different ovine hip were used for allografts. For group 1, autografts matching the original labral width were used. For group 2, autografts twice the original labral width were used. For group 3, allografts matching the original labral width were harvested from a different ovine hip. For group 4, autografts matching the original width were fixed with only 2 anchors. For group 5, autografts matching the original width were tubularized before use. Suction seal force was measured before and after reconstruction using an electromechanical testing system. Statistical analyses included Mann-Whitney U and Wilcoxon signed-rank tests ( P < .05). Results: Group 2 showed the highest improvement in suction seal force, outperforming all other groups ( P < .01). Group 4 exhibited the lowest distractive stability among all groups. Tubularization (group 5) did not enhance biomechanical performance ( P = .752). Group 3, reconstructed with an allograft, exhibited suction seal performance most closely approximating that of group 2, with no significant difference between them. Conclusion: The data from the ovine cadaveric model indicate that increasing the graft size enhances the suction sealing force; however, it remains below the measurements observed in an intact labrum. Furthermore, increasing the number of anchors and optimal graft selection improve postoperative biomechanical stability. Clinical Relevance: Optimizing graft size and fixation techniques in labral reconstruction may improve joint stability and suction seal function and may support surgical strategies aimed at improving outcomes and delaying the progression of osteoarthritis in patients with labral defects.

1 August 2023 in Journal of Surgery and Medicine
Verified
Journal Article
Open access
PDF file
OGOnur Gürsan
Onur Gürsan
MÇMustafa Çeltik
Mustafa Çeltik
CTCihangir Türemiş
Cihangir Türemiş
Background/Aim: Prolonged wound complications and the possibility of reoperations are significant outcomes following minor amputations. As time progresses after the initial surgery, re-amputations become more prevalent. Contrary to prevailing beliefs, the incidence of early amputations remains consistent. Additionally, it is widely acknowledged that the first 6 months following the initial surgery pose the highest risk period for reoperation. This retrospective clinical study aims to investigate the risk factors contributing to ipsilateral re-amputation procedures within 6 months of the initial minor amputation. Methods: A retrospective cohort study was conducted involving amputee patients from 2008 to 2020. Patients with traumatic events, musculoskeletal tumors, prior major amputations, and those who underwent soft tissue procedures such as debridement, incision, drainage, or secondary closure were excluded. Patients who had undergone preoperative lower limb arterial Doppler ultrasound and whose initial preoperative laboratory records were accessible were included. The total cohort comprised 168 patients, comprising 57 women and 109 men. The mean follow-up duration was 1.5 years (range: 1.1–3.2 years). Patients who underwent ipsilateral re-amputation were categorized into two groups based on the timing of the subsequent surgery. The first group comprised 110 (65.5%) patients who underwent ipsilateral re-amputation 6 months after the initial amputation, while the second group encompassed 58 (34.5%) patients who underwent ipsilateral re-amputation within 6 months of the initial amputation. Results: Among the 168 patients, 58 (34.5%) experienced ipsilateral re-amputation within 6 months of their initial minor amputations, while 64.5% underwent re-amputation surgery after the initial 6 months. The absence of peripheral arterial disease was not linked to early re-amputations (P=0.001). Although the mean C-reactive protein values (80.30 mg/dL and 84.26 mg/dL for groups 1 and 2, respectively) did not display significance between the groups (P=0.40), the group undergoing amputation within 6 months demonstrated significance with elevated serum white blood cell mean levels (10.44 mcL and 11.96 mcL for groups 1 and 2, respectively; [P=0.004]). Moreover, lower hemoglobin levels (11.41 g/dL and 10.77 g/dL for groups 1 and 2, respectively) were associated with re-amputation within the initial 6 months following the initial surgery (P=0.024). Conclusion: The study underscores that the incidence of re-amputation after minor amputations in diabetic patients is comparably high, as has been reported in recent literature. While the selection of the initial amputation level remains pivotal, and not all patient-specific factors were examined in this study, the research brings attention to specific laboratory values and the vascular status of the diabetic limb as crucial considerations for surgeons prior to the initial surgery. '+st+' Malay DS, Margolis DJ, Hoffstad OJ, Bellamy S. The incidence and risks of failure to heal after lower extremity amputation for the treatment of diabetic neuropathic foot ulcer. J Foot Ankle Surg. 2006 Nov-Dec;45(6):366-74. DOI: https://doi.org/10.1053/j.jfas.2006.08.002 Thorud JC, Jupiter DC, Lorenzana J, Nguyen TT, Shibuya N. Reoperation and reamputation after transmetatarsal amputation: a systematic review and meta-analysis. J Foot Ankle Surg. 2016;55:1007–12 DOI: https://doi.org/10.1053/j.jfas.2016.05.011 Van Damme H, Limet R. Amputation in diabetic patients. Clin Podiatr Med Surg. 2007;24:569-82. DOI: https://doi.org/10.1016/j.cpm.2007.03.007 Harding JL, Pavkov ME, Gregg EW, Burrows NR. Trends of nontraumatic lower extremity amputation in end-stage renal disease and diabetes: United States, 2000–2015. Diabetes Care. 2019;42:1430-5. DOI: https://doi.org/10.2337/dc19-0296 Nerone VS, Springer KD, Woodruff DM, Atway SA. Reamputation after minor foot amputation in diabetic patients: risk factors leading to limb loss. J Foot Ankle Surg. 2013 Mar-Apr;52(2):184-7. DOI: https://doi.org/10.1053/j.jfas.2012.11.015 Snyder DC, Salameh JR, Clericuzio CP. Retrospective review of forefoot amputations at a Veterans Affairs hospital and evaluation of post-amputation follow-up. Am J Surg. 2006 Nov;192(5):e51-4. DOI: https://doi.org/10.1016/j.amjsurg.2006.08.015 Beaulieu RJ, Grimm JC, Lyu H, Abularrage CJ, Perler BA. Rates and predictors of readmission after minor lower extremity amputations. J Vasc Surg. 2015 Jul;62(1):101-5. DOI: https://doi.org/10.1016/j.jvs.2015.02.021 Izumi Y, Lee S, Satterfield Y, Harkless L. Risk of reamputation in diabetic patients stratified by limb and level of amputation. Diabetes Care. 2006;29:566e70. DOI: https://doi.org/10.2337/diacare.29.03.06.dc05-1992 Skoutas D, Papanas N, Georgiadis GS, Zervas V, Manes C, Maltezos E, et al. Risk factors for ipsilateral reamputation in patients with diabetic foot lesions. Int J Low Extrem Wounds. 2009 Jun;8(2):69-74. DOI: https://doi.org/10.1177/1534734609334808 Stone PA, Back MR, Armstrong PA, Flaherty SK, Keeling WB, Johnson BL, et al. Midfoot amputations expand limb salvage rates for diabetic foot infections. Ann Vasc Surg. 2005 Nov;19(6):805-11. DOI: https://doi.org/10.1007/s10016-005-7973-3 Newhall KA, Bekelis K, Suckow BD, Gottlieb DJ, Farber AE, Goodney PP, et al. The relationship of regional hemoglobin A1c testing and amputation rate among patients with diabetes. Vascular. 2017 Apr;25(2):142-8. DOI: https://doi.org/10.1177/1708538116650099 Nather A, Bee CS, Huak CY, Chew JL, Lin CB, Neo S, et al. Epidemiology of diabetic foot problems and predictive factors for limb loss. J Diabetes Complications. 2008;22:77–82. DOI: https://doi.org/10.1016/j.jdiacomp.2007.04.004 Nasri H, Rafieian-Kopaei M. Diabetes mellitus and renal failure: Prevention and management. J Res Med Sci. 2015 Nov;20(11):1112-20. DOI: https://doi.org/10.4103/1735-1995.172845 Faglia E, Clerici G, Clerissi J, Gabrielli L, Losa S, Mantero M, et al. Early and five-year amputation and survival rate of diabetic patients with critical limb ischemia: data of a cohort study of 564 patients. Eur J Vasc Endovasc Surg. 2006;32:484–90. DOI: https://doi.org/10.1016/j.ejvs.2006.03.006 Ratliff HT, Shibuya N, Jupiter DC. Minor vs. major leg amputation in adults with diabetes: Six-month readmissions, reamputations, and complications. J Diabetes Complications. 2021 May;35(5):107886. DOI: https://doi.org/10.1016/j.jdiacomp.2021.107886 Birmpili P, Li Q, Johal AS, Atkins E, Waton S, Chetter I, et al. Outcomes after minor lower limb amputation for peripheral arterial disease and diabetes: population-based cohort study. Br J Surg. 2023 Jul 17;110(8):958-65. DOI: https://doi.org/10.1093/bjs/znad134 Murdoch DP, Armstrong DG, Dacus JB, Laughlin TJ, Morgan CB, Lavery LA. The natural history of great toe amputations. J Foot Ankle Surg. 1997 May-Jun;36(3):204-8; discussion 256. DOI: https://doi.org/10.1016/S1067-2516(97)80116-0 Joyce A, Yates B, Cichero M. Transmetatarsal amputation: a 12-year retrospective case review of outcomes. Foot 2020;42(July):101637. DOI: https://doi.org/10.1016/j.foot.2019.08.008 Lin JH, Jeon SY, Romano PS, Humphries MD. Rates and timing of subsequent amputation after initial minor amputation. J Vasc Surg. 2020 Jul;72(1):268-75. DOI: https://doi.org/10.1016/j.jvs.2019.10.063 Liu R, Petersen BJ, Rothenberg GM, Armstrong DG. Lower extremity reamputation in people with diabetes: a systematic review and meta-analysis. BMJ Open Diabetes Res Care. 2021 Jun;9(1):e002325. DOI: https://doi.org/10.1136/bmjdrc-2021-002325 Gülcü A, Etli M, Karahan O, Aslan A. Analysis of routine blood markers for predicting amputation/re-amputation risk in diabetic foot. Int Wound J. 2020 Dec;17(6):1996-2004. DOI: https://doi.org/10.1111/iwj.13491 Copyright (c) 2023 Onur Gürsan, Mustafa Çeltik, Cihangir Türemiş This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

28 April 2025 in Transfusion and Apheresis Science
Verified
Journal Article
Closed access
MÇMustafa Çeltik
Mustafa Çeltik
ADAhmet Safa Deniz
Ahmet Safa Deniz
RBResul Bircan
Resul Bircan
IKİbRahim Kaya
İbRahim Kaya
SYSemih Yaş
Semih Yaş
CUCoşkun Ulucaköy
Coşkun Ulucaköy

30 January 2025 in Journal of Hip Preservation Surgery
Verified
Journal Article
Open access
ÖAözgür aydin
özgür aydin
Onur HapaOnur Hapa
Onur Hapa
EAEmre Acar
Emre Acar
MÇMustafa Çeltik
Mustafa Çeltik
SASelahattin Agca
Selahattin Agca
SASelahaddin Aydemir
Selahaddin Aydemir
The alpha angle is a radiological measurement that has been proposed for the detection of cam morphology in patients suspected of femoroacetabular impingement syndrome (FAIS). After analysing published articles on FAIS, it is apparent that different types of circles are used in the measurement of alpha angles. To determine the interobserver and intraobserver reliability of alpha angle values measured using different types of circles on a 45° Dunn lateral radiograph in patients with symptomatic FAIS. The 45° Dunn lateral radiographs of the operated hips of patients who underwent hip preservation surgery in Dokuz Eylül University Hospital between 2014 and 2017 were evaluated retrospectively. Alpha angles were measured manually with transparent goniometers using three different circle types: thin full circle, thin-dashed circle, and thick full circle, and eye estimation without circle insertion. Measurements were made separately by an orthopaedist and a radiologist. A second measurement was made by the radiologist 1 month later for intraobserver reliability. Interobserver reliability for the thin full circle, thin-dashed circle, thick circle, and eye estimation (ICC = 0.645, 0.525, 0.494, and 0.588, respectively). Intraobserver reliability for the thin, thin-dashed, thick line, and eye estimation (ICC= 0.626, 0.681, 0.681, and 0.462 respectively). Interobserver difference of mean values of alpha angles for thin full, thin-dashed, thick full, and eye estimation were 2.7°, 0.9°, 1.1°, and 2.3°, respectively. Intraobserver differences between measurements were 1.5°, 0.9°, 0°, and 1.6°, respectively. Our study demonstrated that interobserver reliability is highest when measurements are made using a thin full circle.