Francisco Fernandez-Lima

Dr. Francisco Fernandez-Lima


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2011 in International Journal for Ion Mobility Spectrometry
Verified
Journal Article
Closed access
PDF file
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima
DKDesmond A. Kaplan
Desmond A. Kaplan
JSJ. Suetering
J. Suetering
MPMelvin A. Park
Melvin A. Park

17 January 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
DHDiana Rosa Hernandez
Diana Rosa Hernandez
JDJohn Daniel DeBord
John Daniel DeBord
MRMark E. Ridgeway
Mark E. Ridgeway
DKDesmond A. Kaplan
Desmond A. Kaplan
MPMelvin A. Park
Melvin A. Park
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima
In the present paper, theoretical simulations and experimental observations are used to describe the ion dynamics in a trapped ion mobility spectrometer. In particular, the ion motion, ion transmission and mobility separation are discussed as a function of the bath gas velocity, radial confinement, analysis time and speed. Mobility analysis and calibration procedure are reported for the case of sphere-like molecules for positive and negative ion modes. Results showed that a maximal mobility resolution can be achieved by optimizing the gas velocity, radial confinement (RF amplitude) and ramp speed (voltage range and ramp time). The mobility resolution scales with the electric field and gas velocity and R = 100–250 can be routinely obtained at room temperature.

1 December 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima
DKD. A. Kaplan
D. A. Kaplan
MPM. A. Park
M. A. Park
The integration of a trapped ion mobility spectrometer (TIMS) with a mass spectrometer (MS) for complementary fast, gas-phase mobility separation prior to mass analysis (TIMS-MS) is described. The ion transmission and mobility separation are discussed as a function of the ion source condition, bath gas velocity, analysis scan speed, RF ion confinement, and downstream ion optical conditions. TIMS mobility resolution depends on the analysis scan speed and the bath gas velocity, with the unique advantage that the IMS separation can be easily tuned from high speed (∼25 ms) for rapid analysis to slower scans for higher mobility resolution (R > 80).

11 November 2009 in Analytical Chemistry
Verified
Journal Article
Closed access
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima
CBChristopher Becker
Christopher Becker
AMAmy M. McKenna
Amy M. McKenna
RRRyan P. Rodgers
Ryan P. Rodgers
AMAlan G. Marshall
Alan G. Marshall
DRDavid H. Russell
David H. Russell

21 March 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
KFKevin Jeanne Dit Fouque
Kevin Jeanne Dit Fouque
CRCesar Enrique Ramirez
Cesar Enrique Ramirez
RLRussell L. Lewis
Russell L. Lewis
JKJeremy P. Koelmel
Jeremy P. Koelmel
TGTimothy J. Garrett
Timothy J. Garrett
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima

5 October 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
KFKevin Jeanne Dit Fouque
Kevin Jeanne Dit Fouque
AGAlyssa Garabedian
Alyssa Garabedian
JPJacob Porter
Jacob Porter
MBMatthew Baird
Matthew Baird
XPXueqin Pang
Xueqin Pang
FFFrancisco Fernandez-Lima
Francisco Fernandez-Lima