Haimin Wang

Dr. Haimin Wang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HWHaimin Wang
Haimin Wang
ZJZhiyuan Ji
Zhiyuan Ji
CWChuanwei Wang
Chuanwei Wang
ZZZexu Zhu
Zexu Zhu
YWYifan Wang
Yifan Wang
HLHao Lin
Hao Lin

17 October 2022 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
HWHaimin Wang
Haimin Wang
ZYZhen Yang
Zhen Yang
CJChenglong Jiang
Chenglong Jiang
ZJZhiyuan Ji
Zhiyuan Ji
ZZZexu Zhu
Zexu Zhu

11 March 2025 in Applied Thermal Engineering
Verified
Journal Article
Closed access
ZJZhiyuan Ji
Zhiyuan Ji
HWHaimin Wang
Haimin Wang
MFMeiya Fu
Meiya Fu
CLChunjing Lin
Chunjing Lin
YXYifeng Xu
Yifeng Xu
YJYixin Jiang
Yixin Jiang

10 June 2020 in SN Applied Sciences
Verified
Journal Article
Closed access
PDF file
HWHaimin Wang
Haimin Wang
HFHu Feng
Hu Feng
KXKong Xiangshuai
Kong Xiangshuai
CSChen Si
Chen Si

30 January 2023 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
HWHaimin Wang
Haimin Wang
ZZZexu Zhu
Zexu Zhu
ZJZhiyuan Ji
Zhiyuan Ji
FHFeng Hu
Feng Hu
HLHao Lin
Hao Lin

1 July 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
HWHaimin Wang
Haimin Wang
SCSi Chen
Si Chen
ZJZhiyuan Ji
Zhiyuan Ji
HLHuanqi Li
Huanqi Li
CJChenglong Jiang
Chenglong Jiang
HLHao Lin
Hao Lin
A novel distributed electric resistance model is used to describe the heat generation characteristics of a cell with the electric resistance of a cell is divided into three parts: the main body, two current collectors, and two electrode tabs. This model was used to simulate the effects of natural convection cooling and forced air convection cooling on tabs of a lithium-ion pouch battery, and the effects of dry air and wet air on the cooling effect. The parameter of the module cooling coefficient (MCC) was introduced to evaluate the effect of thermal management. The results show that wet air has a better cooling effect than dry air, but the cooling effect of wet air with 15% and 75% relative humidity is almost the same, and increasing the inlet air velocity can significantly improve the cooling effect. In addition, the index MCC of positive and negative tabs and the heat flux during cooling process are quantified, so as to provide better service for thermal management design.