Paul RETIF

Dr. Paul RETIF

CHR Metz-Thionville
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in Cancers
Verified
Journal Article
Open access
PDF file
SDSophie Deneuve
Sophie Deneuve
Céline MirjoletCéline Mirjolet
Céline Mirjolet
TBThierry Bastogne
Thierry Bastogne
MDMirlande Duclos
Mirlande Duclos
Paul RETIFPaul RETIF
Paul RETIF
SPSandrine Pereira
Sandrine Pereira
Radiation therapy (RT), either alone or in combination with surgery and/or chemotherapy is a keystone of cancers treatment. Early toxicity is common, sometimes leading to discontinuation of treatment. Recent studies stressed the role of the phosphorylated ATM (pATM) protein in RT-toxicity genesis and its ability in predicting individual radiosensitivity (IRS) in fibroblasts. Here we assessed the reliability of the pATM quantification in lymphocytes to predict IRS. A first retrospective study was performed on 150 blood lymphocytes of patients with several cancer types. Patients were divided into 2 groups, according to the grade of experienced toxicity. The global quantity of pATM molecules was assessed by ELISA on lymphocytes to determine the best threshold value. Then, the binary assay was assessed on a validation cohort of 36 patients with head and neck cancers. The quantity of pATM molecules in each sample of the training cohort was found in agreement with the observed Common Terminology Criteria for Adverse Events (CTCAE) grades with an AUC = 0.71 alone and of 0.77 combined to chemotherapy information. In the validation cohort, the same test was conducted with the following performances: sensitivity = 0.84, specificity = 0.54, AUC = 0.70 and 0.72 combined to chemotherapy. This study provides the basis of an easy to perform assay for clinical use.

1 November 2016 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
Paul RETIFPaul RETIF
Paul RETIF
ARAurélie Reinhard
Aurélie Reinhard
HPHéna Paquot
Héna Paquot
VJValérie Jouan-Hureaux
Valérie Jouan-Hureaux
ACAlicia Chateau
Alicia Chateau
TBThierry Bastogne
Thierry Bastogne
This article addresses the in silico–in vitro prediction issue of organometallic nanoparticles (NPs)-based radiosensitization enhancement. The goal was to carry out computational experiments to quickly identify efficient nanostructures and then to preferentially select the most promising ones for the subsequent in vivo studies. To this aim, this interdisciplinary article introduces a new theoretical Monte Carlo computational ranking method and tests it using 3 different organometallic NPs in terms of size and composition. While the ranking predicted in a classical theoretical scenario did not fit the reference results at all, in contrast, we showed for the first time how our accelerated in silico virtual screening method, based on basic in vitro experimental data (which takes into account the NPs cell biodistribution), was able to predict a relevant ranking in accordance with in vitro clonogenic efficiency. This corroborates the pertinence of such a prior ranking method that could speed up the preclinical development of NPs in radiation therapy.

18 August 2022 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
Paul RETIFPaul RETIF
Paul RETIF
ASAbdourahamane Djibo Sidikou
Abdourahamane Djibo Sidikou
CMChristian Mathis
Christian Mathis
RLRomain Letellier
Romain Letellier
EVEmilie Verrecchia-Ramos
Emilie Verrecchia-Ramos
XMXavier Michel
Xavier Michel

15 March 2021 in Medical Physics
Verified
Journal Article
Closed access
PDF file
Paul RETIFPaul RETIF
Paul RETIF
ASAbdourahamane Djibo Sidikou
Abdourahamane Djibo Sidikou
RLRomain Letellier
Romain Letellier
EVEmilie Verrecchia‐Ramos
Emilie Verrecchia‐Ramos
PQPhilippe Quetin
Philippe Quetin

10 April 2025 in Physica Medica
Verified
Journal Article
Open access
Paul RETIFPaul RETIF
Paul RETIF
ASAbdourahamane Djibo Sidikou
Abdourahamane Djibo Sidikou
JGJulien Gribelbauer
Julien Gribelbauer
ASAnwar Al Salah
Anwar Al Salah
EPEstelle Pfletschinger
Estelle Pfletschinger
XMXavier Michel
Xavier Michel
To evaluate the performance of the VitalHold module for automated Deep Inspiration Breath-Hold (DIBH) treatment on the Radixact platform, focusing on its dosimetric accuracy, responsiveness to respiratory motion and system latency. A Delta4 Phantom+ system with customized 3D-printed breast add-ons was used to simulate a clinically relevant setup for DIBH. A treatment plan was created with 40 Gy in 15 fractions using TomoDirect. The Phantom was coupled with the HexaMotion motion platform to to simulate simple (tested with various amplitude, periods and gating thresholds) and complex respiratory patterns, including irregular breathing, patient-specific motion, and baseline shifts. Respiratory motion was analyzed, and dose distributions were measured using gamma analysis with varying criteria. System latency was evaluated following TG-147 guidelines. The measured simple respiratory curve closely matched the simulated motion, with amplitude differences under 0.1 mm and cycle variations of 0.1 s. Gamma pass rates for 2-5 mm gating tolerances were ≥95 %, indicating high system accuracy. Complex motion scenarios showed average measured amplitude deviations below 0.1 mm. The system exhibited a mean latency of 4.3 ms. The VitalHold module on the Radixact platform demonstrates strong potential for automated DIBH treatment, providing precise and reliable beam control across both simple and complex respiratory patterns and exhibiting minimal latency. This study supports the integration of automated breath-hold techniques in clinical practice.

Verified
Journal Article
Open access
PDF file
Paul RETIFPaul RETIF
Paul RETIF
EVEmilie Verrecchia-Ramos
Emilie Verrecchia-Ramos
MSMotchy Saleh
Motchy Saleh
ASAbdourahamane Djibo Sidikou
Abdourahamane Djibo Sidikou
RLRomain Letellier
Romain Letellier
XMXavier MICHEL
Xavier MICHEL
Background: The re-irradiation of centrally located lung tumors poses substantial risks due to prior dose exposure and proximity to critical structures. Accurate target delineation is crucial to minimize toxicity and ensure tumor coverage. Four-dimensional positron emission tomography/computed tomography (4D-PET/CT) integrates respiratory motion and metabolic data, offering improved delineation over static imaging. Its clinical utility in re-irradiation remains under-reported. Methods: A 67-year-old male presented with the central recurrence of squamous cell carcinoma in the right upper lobe, embedded in radiation-induced fibrosis, following prior chemoradiotherapy. Delineation using static PET underestimated tumor motion. A 4D-PET/CT-guided Stereotactic Body Radiation Therapy (SBRT) plan was developed with a prescription of 60 Gy in eight fractions. A comparative plan using static PET was generated to assess the dosimetric differences. Results: The internal target volume (ITV) from 4D-PET/CT was nearly double the size of the GTV from static PET, with a 5.1 mm discrepancy in the craniocaudal axis. The 4D-PET-based plan achieved 95.0% PTV coverage, while the static PET-based plan covered only 61.7%, illustrating the risk of underdosage without motion-resolved imaging. The patient completed the treatment without acute or late toxicity and showed a sustained metabolic response at one year (SUVmax from 13.4 to 5.8). Conclusions: This case demonstrates the clinical value of 4D-PET/CT in the SBRT re-irradiation of centrally located lung tumors, particularly in fibrotic regions where anatomical imaging is insufficient. It enabled accurate delineation, improved dosimetric coverage, and safe, effective retreatment. These findings support its integration into planning for complex thoracic re-irradiation.