Michael W. Calik

Dr. Michael W. Calik

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2018 in Clinical Autonomic Research
Verified
Journal Article
Closed access
PDF file
Anne M. M FinkAnne M. M Fink
Anne M. M Fink
UBUlf G. Bronas
Ulf G. Bronas
MCMichael W. Calik
Michael W. Calik

1 April 2017 in Nature and Science of Sleep
Verified
Journal Article
Open access
PDF file
MCMichael W. Calik
Michael W. Calik
Narcolepsy is a neurological disease that affects 1 in 2,000 individuals and is characterized by excessive daytime sleepiness (EDS). In 60–70% of individuals with narcolepsy, it is also characterized by cataplexy or a sudden loss of muscle tone that is triggered by positive or negative emotions. Narcolepsy decreases the quality of life of the afflicted individuals. Currently used drugs treat EDS alone (modafinil/armodafinil, methylphenidate, and amphetamine), cataplexy alone (“off-label” use of antidepressants), or both EDS and cataplexy (sodium oxybate). These drugs have abuse, tolerability, and adherence issues. A greater diversity of drug options is needed to treat narcolepsy. The small molecule drug, pitolisant, acts as an inverse agonist/antagonist at the H3 receptor, thus increasing histaminergic tone in the wake promoting system of the brain. Pitolisant has been studied in animal models of narcolepsy and used in clinical trials as a treatment for narcolepsy. A comprehensive search of online databases (eg, Medline, PubMed, EMBASE, the Cochrane Library Database, Ovid MEDLINE, Europe PubMed Central, EBSCOhost CINAHL, ProQuest Research Library, Google Scholar, and ClinicalTrials.gov) was performed. Nonrandomized and randomized studies were included. This review focuses on the outcomes of four clinical trials of pitolisant to treat narcolepsy. These four trials show that pitolisant is an effective drug to treat EDS and cataplexy in narcolepsy.

1 November 2014 in Nature and Science of Sleep
Verified
Journal Article
Open access
TWTerri E. Weaver
Terri E. Weaver
SFSarah S Farabi
Sarah S Farabi
AFAnne M Fink
Anne M Fink
MGMaria T Galang-Boquiren
Maria T Galang-Boquiren
MKMary C Kapella
Mary C Kapella
DCDavid W Carley
David W Carley
Obstructive sleep apnea (OSA) affects one in five adult males and is associated with significant comorbidity, cognitive impairment, excessive daytime sleepiness, and reduced quality of life. For over 25 years, the primary treatment has been continuous positive airway pressure, which introduces a column of air that serves as a pneumatic splint for the upper airway, preventing the airway collapse that is the physiologic definition of this syndrome. However, issues with patient tolerance and unacceptable levels of treatment adherence motivated the exploration of other potential treatments. With greater understanding of the physiologic mechanisms associated with OSA, novel interventions have emerged in the last 5 years. The purpose of this article is to describe new treatments for OSA and associated complex sleep apnea. New approaches to complex sleep apnea have included adaptive servoventilation. There is increased literature on the contribution of behavioral interventions to improve adherence with continuous positive airway pressure that have proven quite effective. New non-surgical treatments include oral pressure devices, improved mandibular advancement devices, nasal expiratory positive airway pressure, and newer approaches to positional therapy. Recent innovations in surgical interventions have included laser-assisted uvulopalatoplasty, radiofrequency ablation, palatal implants, and electrical stimulation of the upper airway muscles. No drugs have been approved to treat OSA, but potential drug therapies have centered on increasing ventilatory drive, altering the arousal threshold, modifying loop gain (a dimensionless value quantifying the stability of the ventilatory control system), or preventing airway collapse by affecting the surface tension. An emerging approach is the application of cannabinoids to increase upper airway tone.

5 July 2017 in SLEEP
Verified
Journal Article
Closed access
PDF file
MCMichael W. Calik
Michael W. Calik
DCDavid W Carley
David W Carley
There are no pharmacological treatments for obstructive sleep apnea syndrome, but dronabinol showed promise in a small pilot study. In anesthetized rats, dronabinol attenuates reflex apnea via activation of cannabinoid (CB) receptors located on vagal afferents; an effect blocked by cannabinoid type 1 (CB1) and/or type 2 (CB2) receptor antagonists. Here, using a natural model of central sleep apnea, we examine the effects of dronabinol, alone and in combination with selective antagonists in conscious rats chronically instrumented to stage sleep and measure cessation of breathing. Adult male Sprague-Dawley rats were anesthetized and implanted with bilateral stainless steel screws into the skull for electroencephalogram recording and bilateral wire electrodes into the nuchal muscles for electromyogram recording. Each animal was recorded by polysomnography on multiple occasions separated by at least 3 days. The study was a fully nested, repeated measures crossover design, such that each rat was recorded following each of 8 intraperitoneal injections: vehicle; vehicle and CB1 antagonist (AM 251); vehicle and CB2 antagonist (AM 630); vehicle and CB1/CB2 antagonist; dronabinol; dronabinol and CB1 antagonist; dronabinol and CB2 antagonist; and dronabinol and CB1/CB2 antagonist. Dronabinol decreased the percent time spent in rapid eye movement (REM) sleep. CB receptor antagonists did not reverse this effect. Dronabinol also decreased apneas during sleep, and this apnea suppression was reversed by CB1 or CB1/CB2 receptor antagonism. Dronabinol’s effects on apneas were dependent on CB1 receptor activation, while dronabinol’s effects on REM sleep were CB receptor-independent.

1 January 2014 in Respiratory Physiology & Neurobiology
Verified
Journal Article
Closed access
MCMichael W. Calik
Michael W. Calik
MRMiodrag Radulovacki
Miodrag Radulovacki
DCDavid W. Carley
David W. Carley

20 October 2022 in Nature and Science of Sleep
Verified
Journal Article
Open access
PDF file
ITIrina Topchiy
Irina Topchiy
Anne M. M FinkAnne M. M Fink
Anne M. M Fink
KMKatherine A Maki
Katherine A Maki
MCMichael W. Calik
Michael W. Calik
Introduction: Current methods of sleep research in rodents involve invasive surgical procedures of EEG and EMG electrodes implantation. Recently, a new method of measuring sleep, PiezoSleep, has been validated against implanted electrodes in mice and rats. PiezoSleep uses a piezoelectric film transducer to detect the rodent’s movements and respiration and employs an algorithm to automatically score sleep. Here, we validate PiezoSleep scoring versus EEG/EMG implanted electrodes sleep scoring in rats. Methods: Adult male Brown Norway and Wistar Kyoto rats were implanted with bilateral stainless-steel screws into the skull for EEG recording and bilateral wire electrodes into the nuchal muscles for EMG assessment. In Brown Norway rats, the EEG/EMG electrode leads were soldered to a miniature connector plug and fixed to the skull. In Wistar Kyoto rats, the EEG/EMG leads were tunneled subcutaneously to a telemetry transmitter implanted in the flank. Rats were allowed to recover from surgery for one week. Brown Norway rats were placed in PiezoSleep cages, and had their headsets connected to cable for recording EEG/EMG signals, which were then manually scored by a human scorer in 10-sec epochs. Wistar Kyoto rats were placed in PiezoSleep cages, and EEG/EMG signals were recorded using a telemetry system (DSI). Sleep was scored automatically in 4-sec epochs using NeuroScore software. PiezoSleep software recorded and scored sleep in the rats. Results: Rats implanted with corded EEG/EMG headsets had 85.6% concurrence of sleep-wake scoring with PiezoSleep. Rats implanted with EEG/EMG telemetry had 80.8% concurrence sleep-wake scoring with PiezoSleep. Sensitivity and specificity rates were similar between the EEG/EMG recording systems. Total sleep time and hourly sleep times did not differ in all three systems. However, automatic sleep detection by NeuroScore classified more sleep during the light period compared to the PiezoSleep. Conclusion: We showed that PiezoSleep system can be a reliable alternative to both automatic and visual EEG/EMG- based sleep-wake scoring in rat.