Pawel Moskal

Prof. Dr. Pawel Moskal


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
SVStefaan Vandenberghe
Stefaan Vandenberghe
PMPawel Moskal
Pawel Moskal
JKJoel S. Karp
Joel S. Karp
The idea of a very sensitive positron emission tomography (PET) system covering a large portion of the body of a patient already dates back to the early 1990s. In the period 2000–2010, only some prototypes with long axial field of view (FOV) have been built, which never resulted in systems used for clinical research. One of the reasons was the limitations in the available detector technology, which did not yet have sufficient energy resolution, timing resolution or countrate capabilities for fully exploiting the benefits of a long axial FOV design. PET was also not yet as widespread as it is today: the growth in oncology, which has become the major application of PET, appeared only after the introduction of PET-CT (early 2000).The detector technology used in most clinical PET systems today has a combination of good energy and timing resolution with higher countrate capabilities and has now been used since more than a decade to build time-of-flight (TOF) PET systems with fully 3D acquisitions. Based on this technology, one can construct total body PET systems and the remaining challenges (data handling, fast image reconstruction, detector cooling) are mostly related to engineering. The direct benefits of long axial FOV systems are mostly related to the higher sensitivity. For single organ imaging, the gain is close to the point source sensitivity which increases linearly with the axial length until it is limited by solid angle and attenuation of the body. The gains for single organ (compared to a fully 3D PET 20-cm axial FOV) are limited to a factor 3–4. But for long objects (like body scans), it increases quadratically with scanner length and factors of 10–40 × higher sensitivity are predicted for the long axial FOV scanner. This application of PET has seen a major increase (mostly in oncology) during the last 2 decades and is now the main type of study in a PET centre. As the technology is available and the full body concept also seems to match with existing applications, the old concept of a total body PET scanner is seeing a clear revival. Several research groups are working on this concept and after showing the potential via extensive simulations; construction of these systems has started about 2 years ago. In the first phase, two PET systems with long axial FOV suitable for large animal imaging were constructed to explore the potential in more experimental settings. Recently, the first completed total body PET systems for human use, a 70-cm-long system, called PennPET Explorer, and a 2-m-long system, called uExplorer, have become reality and first clinical studies have been shown. These results illustrate the large potential of this concept with regard to low-dose imaging, faster scanning, whole-body dynamic imaging and follow-up of tracers over longer periods. This large range of possible technical improvements seems to have the potential to change the current clinical routine and to expand the number of clinical applications of molecular imaging. The J-PET prototype is a prototype system with a long axial FOV built from axially arranged plastic scintillator strips.This paper gives an overview of the recent technical developments with regard to PET scanners with a long axial FOV covering at least the majority of the body (so called total body PET systems). After explaining the benefits and challenges of total body PET systems, the different total body PET system designs proposed for large animal and clinical imaging are described in detail. The axial length is one of the major factors determining the total cost of the system, but there are also other options in detector technology, design and processing for reducing the cost these systems. The limitations and advantages of different designs for research and clinical use are discussed taking into account potential applications and the increased cost of these systems.

1 March 2013 in Physics Letters B
Verified
Journal Article
Closed access
DBD. Babusci
D. Babusci
DBD. Badoni
D. Badoni
IBI. Balwierz-Pytko
I. Balwierz-Pytko
GBG. Bencivenni
G. Bencivenni
CBC. Bini
C. Bini
JZJ. Zdebik
J. Zdebik

17 June 2011 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
PAP. Adlarson
P. Adlarson
CAC. Adolph
C. Adolph
WAW. Augustyniak
W. Augustyniak
VBV. Baru
V. Baru
MBM. Bashkanov
M. Bashkanov
PŻP. Żuprański
P. Żuprański
We report on an exclusive and kinematically complete high-statistics measurement of the basic double-pionic fusion reaction pn→dπ0π0 over the full energy region of the ABC effect, a pronounced low-mass enhancement in the ππ-invariant mass spectrum. The measurements, which cover also the transition region to the conventional t-channel ΔΔ process, were performed with the upgraded WASA detector setup at COSY. The data reveal the Abashian-Booth-Crowe effect to be uniquely correlated with a Lorentzian energy dependence in the integral cross section. The observables are consistent with a narrow resonance with m=2.37  GeV, Γ≈70  MeV and I(JP)=0(3+) in both pn and ΔΔ systems. Necessary further tests of the resonance interpretation are discussed.

1 January 2012 in Physics Letters B
Verified
Journal Article
Open access
FAF. Archilli
F. Archilli
DBD. Babusci
D. Babusci
DBD. Badoni
D. Badoni
IBI. Balwierz
I. Balwierz
GBG. Bencivenni
G. Bencivenni
JZJ. Zdebik
J. Zdebik
"The existence of a light dark force mediator has been tested with the KLOE detector at DA��NE. This particle, called U, is searched for using the decay chain φ → ηU, η → π+π−π0, U → e+e−. No evidence is found in 1.5 fb−1 of data. The resulting exclusion plot covers the mass range 5 < MU < 470 MeV, setting an upper limit on the ratio between the U boson coupling constant and the fine structure constant, α′\/α, of ��2×10−5 at 90% C.L. for 50

22 June 2010 in The European Physical Journal C
Verified
Journal Article
Closed access
PDF file
GAG. Amelino-Camelia
G. Amelino-Camelia
FAF. Archilli
F. Archilli
DBD. Babusci
D. Babusci
DBD. Badoni
D. Badoni
GBG. Bencivenni
G. Bencivenni
JZJ. Zdebik
J. Zdebik

1 November 2015 in Physics Letters B
Verified
Journal Article
Open access
AAA. Anastasi
A. Anastasi
DBD. Babusci
D. Babusci
GBG. Bencivenni
G. Bencivenni
MBM. Berlowski
M. Berlowski
CBC. Bloise
C. Bloise
MWM. Wolke
M. Wolke
The existence of a new force beyond the Standard Model is compelling because it could explain several striking astrophysical observations which fail standard interpretations. We searched for the light vector mediator of this dark force, the Uboson, with the KLOE detector at the DAFNE e+e−collider. Using an integrated luminosity of 1.54fb−1, we studied the process e+e−→Uγ, with U →e+e−, using radiative return to search for a resonant peak in the dielectron invariant-mass distribution. We did not find ev-idence for a signal, and set a 90%CL upper limit on the mixing strength between the Standard Model photon and the dark photon, ε2, at 10−6–10−4in the 5–520MeV/c2mass range