Renzo Nesti

Dr. Renzo Nesti

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2010 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
MBM. Bersanelli
M. Bersanelli
NMN. Mandolesi
N. Mandolesi
RBR. C. Butler
R. C. Butler
AMAniello Mennella
Aniello Mennella
FVF. Villa
F. Villa
AZA. Zonca
A. Zonca
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA programme dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100–850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art indium phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front end is cooled to 20 K for optimal sensitivity and the reference loads are cooled to 4 K to minimise low-frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements, and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical, and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.

1 December 2011 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
AMAniello Mennella
Aniello Mennella
MBM. Bersanelli
M. Bersanelli
RBR. C. Butler
R. C. Butler
ACA. Curto
A. Curto
FCF. Cuttaia
F. Cuttaia
FWF. Winder
F. Winder
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.

15 September 2010 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
NMN. Mandolesi
N. Mandolesi
MBM. Bersanelli
M. Bersanelli
RBR. C. Butler
R. C. Butler
EAEduardo Artal
Eduardo Artal
CBC. Baccigalupi
C. Baccigalupi
AZA. Zonca
A. Zonca
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27–77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.

2 October 2007 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
MFM. Felli
M. Felli
JBJ. Brand
J. Brand
RCR. Cesaroni
R. Cesaroni
CCC. Codella
C. Codella
GCG. Comoretto
G. Comoretto
RVR. Valdettaro
R. Valdettaro
Context.Water vapor emission at 22 GHz from masers associated with star-forming regions is highly variable.Aims.We present a database of up to 20 years of monitoring of a sample of 43 masers within star-forming regions. The sample covers a large range of luminosities of the associated IRAS source and is representative of the entire population of H2O masers of this type. The database forms a good starting point for any further study of H2O maser variability.Methods.The observations were obtained with the Medicina 32-m radiotelescope, at a rate of 4-5 observations per year.Results.To provide a database that can be easily accessed through the web, we give for each source: plots of the calibrated spectra, the velocity-time-flux density plot, the light curve of the integrated flux, the lower and upper envelopes of the maser emission, the mean spectrum, and the rate of the maser occurrence as a function of velocity. Figures for just one source are given in the text for representative purposes. Figures for all the sources are given in electronic form the appendix. A discussion of the main properties of the H2O variability in our sample will be presented in a forthcoming paper.

9 December 2008 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
Alessandro NavarriniAlessandro Navarrini
Alessandro Navarrini
RNRenzo Nesti
Renzo Nesti
We describe the design, construction, and performance of a waveguide orthomode transducer (OMT) for the 3-mm band (84-116 GHz). The OMT is based on a symmetric backward coupling structure and has a square waveguide input port (2.54 mm times 2.54 mm) and two single-mode waveguide outputs: a standard WR10 rectangular waveguide (2.54 mm times 1.27 mm), and an oval waveguide with full-radius corners. The reverse coupling structure is located in the common square waveguide arm and splits one polarization signal in two opposite rectangular waveguide sidearms using broadband -3-dB .E-plane branch-line hybrid couplers. The device was optimized using a commercial 3-D electromagnetic simulator. The OMT consists of two mechanical blocks fabricated in split- block configuration using conventional CNC milling machine. From 84 to 116 GHz, the measured input reflection coefficient was less than -17 dB, the cross polarization was less than -30 dB, the isolation between the outputs was greater than 50 dB, and the insertion loss was less than 0.35 dB at room temperature for both polarization channels. The device is suitable for scaling to higher frequency.

4 February 2020 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
PYP Yagoubov
P Yagoubov
TMT Mroczkowski
T Mroczkowski
VBV Belitsky
V Belitsky
DCD Cuadrado-Calle
D Cuadrado-Calle
FCF Cuttaia
F Cuttaia
NWN Wadefalk
N Wadefalk
Context. The Atacama Large Millimeter/submillimeter Array (ALMA) has been in operation since 2011, but it has not yet been populated with the full suite of its planned frequency bands. In particular, ALMA Band 2 (67−90 GHz) is the final band in the original ALMA band definition to be approved for production. Aims. We aim to produce a wideband, tuneable, sideband-separating receiver with 28 GHz of instantaneous bandwidth per polarisation operating in the sky frequency range of 67−116 GHz. Our design anticipates new ALMA requirements following the recommendations of the 2030 ALMA Development Roadmap. Methods. The cryogenic cartridge is designed to be compatible with the ALMA Band 2 cartridge slot, where the coldest components – the feedhorns, orthomode transducers, and cryogenic low noise amplifiers – operate at a temperature of 15 K. We use multiple simulation methods and tools to optimise our designs for both the passive optics and the active components. The cryogenic cartridge is interfaced with a room-temperature (warm) cartridge hosting the local oscillator and the downconverter module. This warm cartridge is largely based on GaAs semiconductor technology and is optimised to match the cryogenic receiver bandwidth with the required instantaneous local oscillator frequency tuning range. Results. Our collaboration has resulted in the design, fabrication, and testing of multiple technical solutions for each of the receiver components, producing a state-of-the-art receiver covering the full ALMA Band 2 and 3 atmospheric window. The receiver is suitable for deployment on ALMA in the coming years and it is capable of dual-polarisation, sideband-separating observations in intermediate frequency bands spanning 4−18 GHz for a total of 28 GHz on-sky bandwidth per polarisation channel. Conclusions. We conclude that the 67−116 GHz wideband implementation for ALMA Band 2 is now feasible and that this receiver provides a compelling instrumental upgrade for ALMA that will enhance observational capabilities and scientific reach.